-

-

+90(212)320 36 50
6,6425
$5,79
K7M-DR40S/DC
  • K7M-DR40S/DC
Marka: LS ( LG )

Seri:K80 SERİSİ KOMPAK TİP PLC

Model: K7M-DR40S/DC

Model Birim Fiyat Birim Fiyat Adet Stok
K7M-DR40S/DC 24 DC Giriş , 16 RL ÇıkışFiyat Sorunuz: 0212 320 36 50
  • Ürün Hakkında
  • Dokümanlar
  • Yazılımlar
  • Bağlantı Şeması
- 0.5 µsn/step İşletim Hızı
- 7 Kstep Program Kapasitesi
- Maksimum 80 G/Ç
- NPN/PNP Seçilebilir Dijital Giriş
- Röle ve NPN Transistör Çıkış
- 1 Adet Hızlı Sayıcı Girişi (1Ø 16kHz,2Ø 8kHz)
- 1 Adet Pulse Çıkış (2 kHz )( NPN )
- 8 Adet PID Kontrol
- 8 Adet Pulse Yakalama Girişi (0.2ms)
- 8 Adet Harici Kesme Girişi
- 8 Adet Filtrenebilir Giriş (0-5ms)
- Dahili RS232 Port
- Ücretsiz Pogramlama Yazılım
K7M-DR40S/DC


--------------------G7F-AD2A Analog Input Manuel.pdf-----------------
Materials for GLOFA-GM o Safety Precautions Name Code Remark > Safety Precautions is for using the product safe and correct in order to prevent the DATA SHEET GMWIN (Programming software) 10310000376 1) Offset/gain value can’t be changed, because it is fixed. accidents and danger, so please go by them. GLOFA-GM (Instruction & Programming) 10310000377 2) Analog inputting is set the current since this is manufactured. > The precautions explained here only apply to the G7F-AD2A unit. For safety precautions GLOFA-GM7 User’s manual 10310000374 3) It is possible to use to extend max.2 Modules. on the PLC system, refer to the GLOFA-GM7 or MASTER-K80S User’s manual. LG Programmable Logic Controller 4) The A/D conversion module is possible to use according to ROM version number Materials for MASTER-K > The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the meanings Analog to Digital Conversion Module condition.(GM7 : more than V1.3, K80S : more than V1.4, KGL-WIN : more than V2.14) Name Code is represented as follows. KGL-WIN (Programming software) 10310000345 If violated instructions, it can cause death, fatal injury or G7F-AD2A Warning MASTER-K (Instruction & Programming) 10310000347 considerable loss of property. 4. Names of parts and functions MASTER-K80S User’s manual 10310000373 If violated instructions, it can cause a slight injury or slight loss Caution of products > The symbols which are indicated in the PLC and User’s Manual mean as follows 1. Introduction This symbol means paying attention because of danger of injury, fire, or malfunction. ? ? The G7F-AD2A is Analog to Digital conversion module for use with the GLOFA This symbol means paying attention because of danger of electrical shock. GM7 and MASTER-K80S series. This module is to convert an analog input signal (voltage or current) from external sensors into a 12-bit Binary digital value, > Store this datasheet in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. 24V 24G Warning 2. General Specifications Input > Do not contact the terminals while the power is applied. No Item Specifications Standard Risk of electric shock and malfunction 1 Operating temperature 0 ~ 55? ? 2 Storage temperature -25 ~ 75? > Protect the product from being gone into by foreign metallic matter. 3 Operating Humidity 5 ~ 95%RH, non-condensing Input 4 Storage humidity 5 ~ 95%RH, non-condensing Risk of fire, electric shock and malfunction. Select CH0 CH1 CH2 CH3 Occasional vibration CH3 V0 COM0 V1 COM1 V2 COM2 V3 COM3 Sweep CH2 Frequency Acceleration Amplitude V I CH1 Caution count ? I0 · I1 · I2 · I3 · CH0 10?f?57 Hz - 0.075 mm 10 times in 57 ?f?150 Hz 9.8? {1G} - 5 Vibration IEC 61131-2 LG Industrial Systems > Be sure to check the rated voltage and terminal arrangement for the each Continuous vibration direction module before wiring work. Frequency Acceleration Amplitude for X, Y, Z Risk of electric shock, fire and malfunction 10?f?57 Hz - 0.035 mm - When using LGIS equipment, thoroughly read this datasheet 57?f?150 Hz 4.9?{0.5G} - ? ? > Tighten the screw of terminal block with the specified torque range. and associated manuals introduced in this datasheet. Also pay *Maximum shock acceleration: 147? {15G} *Duration time :11 ms If the terminal screw looses, it can cause fire and electric shock. 6 Shocks IEC 61131-2 careful attention to safety and handle the module properly. *Pulse wave: half sine wave pulse( 3 times in each of X, Y and Z directions ) - Store this datasheet in a safe place so that you can take it out > Use the PLC in an environment that meets the general specifications Square wave impulse LGIS and read it whenever necessary. ±1,500 V noise contained in this datasheet. Standard Electrostatic IEC 61131-2 Risk of electrical shock, fire, erroneous operation and deterioration of the PLC. Voltage :4kV(contact discharge) discharge IEC 1000-4-2 Radiated IEC 61131-2 > Be sure that external load does not exceed the rating of output module. 27 ~ 500 MHz, 10 V/m 7 Noise immunity electromagnetic field IEC 1000-4-3 Risk of fire and erroneous operation. Digital I/Os Digital No Contents Fast transient Severity I/Os All power (Ue < 24 V) IEC 61131-2 ( Ue modules RUN LED & Level > Do not use the PLC in the environment of direct vibration Analog I/Os IEC 1000-4-4 ? ? 24 V) communication I/Os burst noise Indicate the operating status the G7F-AD2A Risk of electrical shock, fire and erroneous operation. Voltage 2 kV 1 kV 0.25 kV Analog input terminal 8 Atmosphere Free from corrosive gases and excessive dust > Do not disassemble, repair or modify the PLC. Voltage Input Current input 9 Altitude for use Up to 2,000m CH0 CH0 Risk of electrical shock, fire and erroneous operation. 10 Pollution degree 2 or lower V0 COM0 V0 COM0 • Head Office 11 Cooling method Self-cooling th > When disposing of PLC and battery, treat it as industrial waste. · LG Twin Towers East Bldg. 9 Floor, 20, Yoido-Dong Youngdungpo-Gu, I0 · I0 ? Seoul 150-721, KOREA Risk of poisonous pollution or explosion. 3. Performance Specifications • Domestic Sales Team PLC sales team TEL:+82-2-3777-4620~34 FAX:+82-2-3777-4622 Precautions for use Busan sales team TEL:+82-51-310-6855~60 FAX:+82-51-310-6851 Item Specifications ? When current input is used, short the V and I terminal. Deagu sales team TEL:+82-53-603-7740~5 FAX:+82-53-603-7788 > Do not Install other places except PLC controlled place. Voltage DC 0~10V (input resistance more than 1?) Jumper pin of analog input Gaungju sales team TEL:+82-62-510-1885~91 FAX:+82-62-526-3262 DC 0~20? (input resistance 250?) > Make sure that the FG terminal is grounded with class 3 grounding which is dedicated to Current Voltage Input Current input Deajeon sales team TEL:+82-42-820-4240~2 FAX:+82-42-820-4298 DC 4~20? (input resistance 250?) the PLC. Otherwise, it can cause disorder or malfunction of PLC Analog CH3 • Overseas Sales Team - Setting by input terminal CH3 CH3 Input CH2 CH2 PLC sales team TEL:+82-2-3777-4640~7 FAX:+82-2-3777-4648~9 Others Others Others (When current input is used, short the V and I terminal) CH2 PLC PLC PLC CH1 CH1 Voltage/Current CH1 - When current input is used in GLOFA, the function blocks which CHO ? CHO Selection V I CHO is used are different by input range • Web site - In MASTER-K, voltage/current is selected by KGL-WIN parameter http://www.lgis.co.kr (Korean) < Best > < Good > < Bad > http://www.lgis.com (English) Digital output 12bit binary (0~4000) Connect left parts Connect right parts 0~10VDC 2.5? (1/4000) > Connect expansion connector correctly when expansion module are needed, by jumper pins by jumper pins Max. • Overseas Branches DC 0~20? 5? (1/4000 ) resolution > Do not detach PCB from the case of the module and do not modify the module. USA New Jersey Branch +1-201-816-2985 DC 4~20? 5? (1/3200 ) China Beijing Branch +86-10-6462-3254~9 Accuracy ±0.5% [Full scale ] External power input terminal > Turn off power when attaching or detaching module. ? Shanghai Branch +86-21-6278-4370 Max. conversion speed 2?/CH + scan time ? External voltage 24VDC needs to this terminal. > Cellular phone or walkie-talkie should be farther than 30cm from the PLC Guangzhou Branch +86-20-8755-3429 Max. absolute input Voltage : ±15V, Current : ±25? Extension cable > Input signal and communication line should be farther than minimum 100mm from a Japan Tokyo Branch +81-3-3582-9128 Number of analog input ? 4channels/module point Vietnam Hanoi Branch +84-4-882-0222 ? This cable is used to connect while analog input module is used.. high-tension line and a power line in order not to be affected by noise and magnetic field. Between Input terminals and PLC power supply Extension cable connector Isolation : Photo coupler isolation ? (No isolation between channels) ?The connector connects extension cable when extended module is used. Before handling the product Terminal connected 2points/16 points terminal block LG constantly endeavors to improve our products so that information in this Internal current Before using the product, read the datasheet and the User’s manual through to the end +5V 100? datasheet is subjected to change without notice. consumption carefully in order to use the product efficiently. Voltage 21.6 ~ 26.4VDC 10310000262 External power Current supply 100? consumption Weight(g) 300g 5. Function Block (only GLOFA series) 7. Handling Precautions 10. Dimension (unit : mm) From unpacking to installation, be sure to check the following: 5.1 Type of function block and function Function 1) Do not drop it off, and make sure that strong impacts should not be applied. Remark ?4.5 block 2) Do not dismount printed circuit boards from the case. It can cause malfunctions. AD2_RD DC 0~10V / DC 4~20? Input only(single type) 3) During wiring, be sure to check any foreign matter like wire scraps should not enter into the AD2A_RD DC 0~10V / DC 4~20? Input only(array type) upper side of the PLC, and in the event that foreign matter entered into it, always eliminate it. AD2_420 DC 4~20? current input only(single type) AD2A_420 DC 4~20? current input only(array type) 4) Be sure to disconnect electrical power before mounting or dismounting the module. GLOFA PROGRAMMABLE PWR 115 95 105 LOGIC CONTROLLER 8. Wiring 5.2 Reading A/D conversion value (AD2_RD, AD2_420) Single type of function block for reading the module is performed for only one channel 8.1 Caution for wiring and the specified channel is used to read output variable of data displayed from A/D ?Make sure that external input signal of the mixture module of AC and analog I/O is not converted digital value. affected by induction noise or occurs from the AC through using another cable. Types of Classifi Data 5 Variable Contents function block cation type ?Wire is adopted with consideration about peripheral temperature and electric current Execution request region of function block allowance. Thicker than Max. size of wire AWG22 (0.3?) is better. ? If connected condition on then region is completed and AD2_RD REQ BOOL ?If wire is put near to high temp. radiated device or contacted with oil for a long time, it may 0 turns to 1, then function block of reading module is REQ DONE cause of electric leakage so that it gets broken or miss-operation during wiring. executed while the program is performing Location no. of slot ?Be sure to connect with care of polarity while connecting to external 24V DC power supply. SLOT USINT SLOT STAT ? Setting range:1 to 3 ?In case of wiring with high voltage line or generation line, it makes induction failure so then it Input 73 Designation region of using channel CH BOOL may cause of miss-operation and out of order. CH DATA ? Setting range:0 to 3 Designation region of Analog input type. V_I 8.2 Wiring ?Setting range:0 or 1(0: Current selecting, 1:Voltage V_I BOOL selecting) 95 ? It isn’t used in function block AD2_420 Current Input Output DONE Indicating region of function block execution complete Voltage Input AD2_420 Terminal Terminal ? If reading function block is completed to execute BOOL without an error then 1 is output and maintains 1 until REQ DONE V0 V1 + + next execution comes, but if an error occurs, 0 is output and if becomes operation stop status. Analog SLOT STAT Analog 11. Warranty I0 I1 Input STAT Area marking error status Input USINT CH DATA ? When error occurs, output error numbers. COM1 COM0 Area outputting A/D conversion value DATA INT 1. Warranty period *1 *1 ? Data output range: 0 ~ 4000 LGIS provides an 18-month-warranty from the date of the production. 5.3 Reading A/D conversion value (AD2A_RD, AD2A_420) *1 : Be sure to use two-core twisted shield wire. 2. Warranty conditions Array type of function block for reading the module is performed for only one channel and the For troubles within the warranty period, LGIS will replace the entire PLC or repair the specified channel is used to read output variable of data displayed from A/D converted digital troubled parts free of charge except the following cases. value. 9. I/O conversion characteristics Type of Variable Data I/O Contents function block s type (1) The troubles caused by improper condition, environment or treatment except the Execution request region of function block 1) Voltage Input ? If connected condition on this region is completed and instructions of LGIS. REQ BOOL 0 turns to 1 then function block of writing module is (2) The troubles caused by external devices. 4000 executed while the program is performing. AD2A_RD Location no. of slot (3) The troubles caused by remodeling or repairing based on the user’s own discretion. 2004 SLOT USINT ? Setting range:1 to 3 DONE REQ 2003 (4) The troubles caused by improper usage of the product. Designation region of using channel 2002 BOOL ? Setting range:0 to 3 (5) The troubles caused by the reason which exceeded the expectation from science and SLOT STAT Input CH 2000 [Array] ? The number of element is 4, this number means 2001 technology level when LGIS manufactured the product. channel number CH DATA 2000 Designation region of Analog input type. (6) The troubles caused by natural disaster. V_I ?Setting range:0 or 1(0: Current selecting, 1:Voltage INT selecting) 0 V_I 0V 5V 10V [Array] ? The number of element is 4, this number means 3. This warranty is limited to the PLC itself only. It is not valid for the whole system which the input voltage channel number Analog input voltage PLC is attached to. ? It isn’t used in function block AD2_420 Indicating region of function block execution complete A/D conversion characteristics (voltage input) ? If writing function block is completed to execute In voltage input, digital amount 0 is output by 0V input and 4,000 is output by 10V input. DONE BOOL without an error then 1 is output and maintains 1 until AD2A_420 Therefore input 2.5mV equals to digital amount 1, but value less than 2.5mV can’t be nest execution comes, but if an error occurs, 0 is REQ DONE output and it becomes operation stop status converted. Output Area for marking error status, that outputs error number when STAT USINT 2) Current Input SLOT STAT error occurs in execution of function block. Area outputting A/D conversion value CH DATA INT ? Data output range: 0 ~ 4000 DATA 4000 [Array] ? The number of element is 4, this number means channel number 2004 2003 2002 6. Special data register (only MASTER-K series) 2000 2001 2000 A/D conversion value stores special data register as following. Special data Explanation Remark register 0 0 mA 5 mA 20 mA D4980 A/D conversion value of channel 0 stores input D4981 A/D conversion value of channel 1 stores current Expansion A/D module #1 Analog input current D4982 A/D conversion value of channel 2 stores D4983 A/D conversion value of channel 3 stores A/D conversion characteristics (Current input) D4984 A/D conversion value of channel 0 stores Current input 0mA becomes output 0, 10mA does 2000 and 20mA does 4000. therefore D4985 A/D conversion value of channel 1 stores input 5? equals to digital amount 1, but value less tan 5? can’t be converted. So Expansion A/D module #2 D4986 A/D conversion value of channel 2 stores abandon it. D4987 A/D conversion value of channel 3 stores Digital output value Digital output value Digital output value Digital output value 10.000mA 5.000V 10.005mA 5.0025V
E-endustri.com'u takip edin
e-endustri.com Hesaplı Alışveriş Kredi kartları