-

-

+90(212)320 36 50
5,5029
$4,7233
WMS-F-C51-5
  • WMS-F-C51-5
Marka: Hanyoung

Seri:WMS Serisi

Model: WMS-F-C51-5

Model Birim Fiyat Birim Fiyat Adet Stok
WMS-F-C51-55' li , FlaşörFiyat Sorunuz: 0212 320 36 50
  • Ürün Hakkında
  • Dokümanlar
  • Yazılımlar
• 24 VAC/DC Besleme
• 60 Flaş/Dakika
• A : Sürekli Işık
• F : Sürekli , Flaş , Buzzer
• NPN/PN


    --------------------AX Serisi Manuel.pdf-----------------
    MA0613E140331 Digital temperature controller AX series INSTRUCTION MANUAL HANYOUNGNUX CO.,LTD 28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea Thank you for purchasing HANYOUNG product. HEAD OFFICE TEL : (82-32)876-4697 FAX : (82-32)876-4696 http://www.hynux.com Please check whether the product is the exactly same as you ordered. PT. HANYOUNG ELECTRONIC INDONESIA Before using the product, please read this instruction manual carefully. Jl. cempaka blok F16, No.02 Delta Silicon II Cikarang Bekasi Indonesia INDONESIA Please keep this manual where you can view at any time FACTORY TEL : 62-21-8911-8120~4 FAX : 62-21-8911-8126 •Some parts in this product have life expectancy and gets old as time elapses. Safety information •The warranty period is one year including the parts only under the condition where the Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality product is used properly •It needs the preparation time for contact output when supplying in the power. When DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury DANGER applied as signal to the external interlock circuit and etc, please jointly use the delay relay. WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury WARNING • When changing the instrument or if the product broke down, users can replace with the prepared product but even suffix code stays same, operation may differ due to the CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury CAUTION parameter difference so please check for the compatibility and perform such action. •Before using a temperature controller, there could be a temperature difference between PV DANGER of the temperature controller and the actual temperature so please operate the temperature The electric shock may occur in the input/output terminal so please never let your body and/ controller after compensating the temperature difference appropriately. or conductive substance to be contacted by the input/output terminal. Suffix code WARNING Model Code Information •Since this product is not designed as a safely used device the user must install double AX ?- ? ? Digital temperature controller safety equipment when this product is used for equipment with possible fatal accident or large property damage. 2 AX2 : 48 X 96 ? •The power switch and fuse are not installed on this product so users need to install them 3 AX3 : 96 X 48 ? separately on the outside. (Fuse rating : 250 V 0.5 A) •Please supply in the rated power supply voltage in order to prevent this product from Dimension 4 AX4 : 48 X 48 ? breaking down or damaged. 7 AX7 : 72 X 72 ? • To prevent electric shock or devise malfunction of this product , do not supply the power until 9 AX9 : 96 X 96 ? the wiring is completed. •This is not designed as explosion-protective structure so avoid using this product at places Relay or SSR as control 1 SSR + Relay1 + Relay2 where gas inflammability and explosive gases exist. output(selectable in •Do not supply in the power until all wiring is fully completed in order to prevent the product 2 SSR + Relay1 + Relay2 + Relay3 operator setup mode) from breaking down and prevent users from getting electric shock. 1B SSR + Relay1(Form c) + Relay2 Only for AX2, 3, 7, 9 •Do not disassemble, manufacture, upgrade and repair the product by yourself. Doing so Output selection will break down the product, generate the electric shock and cause malfunction to occur. 2B SSR + Relay1(Form c) + Relay2 + Relay3 •Please turn OFF the product and disassemble the product. Not doing so will break down 3 4 - 20 ? + Relay2 Current output as control the product, generate the electric shock and cause malfunction to occur. output •Electric shock may occur when operating this product so please install this product to the panel and use it 4 4 - 20 ? + Relay2 + Relay3 Power supply voltage A 100 - 240 V AC 50/60 Hz CAUTION ? Form C : Normal close type contact •The contents of this manual may be changed without prior notification ? Relay output operates as control output, alarm output and LBA output depending on the •Please check for correct model type and specification internal parameter setting. •Please check for any damage or abnormality may caused during shipment. •Please use this product at following range. Ambient temperature : -5 ~ 50 ? (when installing them close to each other, max. 40 ?) / Input humidity : 35 ~ 85 % R.H (but without dew condensation) Multi input (selectable in operator setup mode) •Please avoid the places where corrosive gas(especially noxious gas, ammonia and etc) and inflammable gas exist Input selection •Thermocouple : K, J, R, T (IEC) •Please do not use this product at places where the vibration or impact is applied directly. •RTD : Pt100 ?(IEC) •Please avoid the places where liquid, oil, medical substances, dust, salt or iron contents Input sampling time 0.1 sec exist(avoid place of pollution level 1 or 2) •Do not clean the product with the organic solvent such as alcohols, benzene and etc. (Use neutral detergents) Input impedance 1 ? max •Please avoid the places where huge inductive interference exists and places where static Allowable wiring 10 ?/ 1 wire max (RTD). electricity/self noise are generated. resistance but resistances among 3 wires should be same •Please avoid the places where heat accumulates due to the direct sunlight, radiation and etc •We recommend using it at altitude below the 2000 m. Allowable input voltage 10 V DC max •If the device is touched or contacted by water then short-circuit and fire may occur so please inspect the device carefully. Performance •With the thermocouple input, please use the stated compensation cable. ±0.3 % of F.S ±1 digit (Using regular compensation cable will generate the temperature error) Display accuracy •With the RTD input, please use the cable with less lead-wire resistance and no difference in (In case of R type, ±1.0 % of ±1 digit in the 0 ~ 600 ? range) the resistance among 3-wires. (Using regular cable will generate the temperature error) Insulation resistance More than 20 ?, 500 V DC for 1min (Primary terminal-Secondary terminal) •For the input signal wire, please avoid from the power line and load line in order to avoid Dielectric strength 2300 V AC 50/60Hz, for 1 min (Primary terminal-Secondary terminal) from the induction noise. •Separate the input signal wire and output signal wire and if separating them from each other is impossible, then please use the shield wire for the input signal wire. Range and input code •For the thermocouple, please use It as the un-grounding type. Range (When using the grounding type, malfunction may occur due to the electric leakage) Classification Code Input type •When there are too much noises generating from the power, we recommend using the insulation Celsius (?) Fahrenheit (?) Trans and noise filter. Noise filter must be mounted to the panel or etc that is grounded and - 100 ~ 1200 -148 ~ 2192 please try to make the wiring of output and power terminal meter as short as possible. K •Tightly twisting the power line meter will reduce the noise generation -100.0 ~ 500.0 -148 ~ 932 •If alarm function is not set properly, alarm will not be generated when it should so please Thermocouple J -100.0 ~ 500.0 -148 ~ 932 check for the operation before running the product. R 0 ~ 1700 32 ~ 3092 •When replacing the sensor, please turn OFF the power •If operation frequency is too high (such as proportional operation and etc) and connecting T -100.0 ~ 400.0 -148 ~ 752 the maximum rated load to output relay will shorten the life expectancy therefore, please use RTD Pt100 ? -100.0 ~ 400.0 -148.0 ~ 752.0 the auxiliary relay. We recommend using the SSR output type in such cases. - When using the electrical switch: Set proportional cycle min 20 sec - When using the SSR: Set proportional cycle min 1 sec Control function and output •Do not wire anything to the un-using terminal •Control type : PID control, P control, ON/OFF control •Please check the polarity of terminal before wiring. •Auto-tuning : PID operation by the auto-tuning •When installing this product to the panel, please use the authorized switch or circuit •ON/OFF control : When PV > SV, it generates 0 % output. breaker (authorized by IEC60947-1 or IEC60947-3) When PV < SV, it generates 100 % output. (Only when control hysteresis is 0) •Please install the switch or circuit breaker close to the operator for users’convenience •Because switch or circuit breaker is being installed, please make a note on the panel that •Manual reset : Users set within the range from 0 % to 100 %. operating the switch or circuit breaker will block the power. •Control output operation : Direct action/Reverse action (selected by the parameter setting) •We recommend the continuous inspection and repair in order to use it safely for a long period of time. •Control output : Relay output/voltage pulse output (SSR output) * Selected by the parameter setting1a contact, 3 A 240 V AC, 3 A 30 V DC (Resistive load) ? Alarm output LOCK It the value is ON, Alarm is not cancelled evenif it becomes the alarm cancel condition. •Relay output can be selected maximum 3 and relay control output Relay is displayed as RLY1. If users want to stop the alarm forcedly, please press the key for approx 2 sec. •Alarm output 2 contacts (AL1, AL2) and LBA output are assigned by the users among RLY1, RLY2 and RLY3 - LBA (Loop Break Alarm) CYC LBA function starts to measure time from the moment when the PID computed value 12 - 15 V DC pulse voltage S.S.R becomes 0 % or 100 %. Also, from this point, this function detects heater break, sensor break (resistive load min 600 ?) PHA manipulator malfunction and etc by comparing the changed amount of measured value in 4 - 20 ? Accuracy : 0.5 % of F.S, Ripple Vp-p : 0.3 % of F.S, Resistive load : Max 600 ? each set time. Also, it can set the LBA dead band in order to prevent any malfunction to happen in the normal control loop. ? When control output value which obtained by PID operation is 100 %, Specification If the temperature does increase more than value within the LBA set time, Model ??2 ??3 ??4 ??7 ??9 LBA output will become ON Power supply voltage 100 - 240 V AC 50/60 Hz ? When control output value which obtained by PID operation is 0 %, Voltage fluctuation ±10 % of power supply voltage If the temperature does decrease more than value within the LBA set time, LBA output will become ON Power consumption 5.5 VA max - Timeshare cycle control and phase control of Voltage pulse output Ambient temperature -5 ~ 50 ? When selecting the control output type as SSR, users will be able to select the types for voltage Ambient humidity 35 ~ 85 % R.H (But without dew condensation) pulse output. The timeshare cycle control turns ON/OFF the output by proportioning the certain Vibration (resistance) 10 - 55 Hz, 0.75 ?, X Y Z each in X, Y and Z directions for 2 hour time to an output amount in cycle. Set the cycle of control output in the parameter. Shock (resistance) 300 m/s² to 6 directions each 3 times Within the half cycle of power wave shape, the phase control (depending on an output amount) Weight 320 g 320 g 180 g 300 g 400 g controls an output amount by computing the output ON phase. However, when using the phase control, users must use the RANDOM ON/OFF type SSR. ? Weight included the weight of box Control type Load current with 50 % of output Function and name of each part 50 % of AC LINE cycle Phase control ? Process value (PV) ? Operation indicators AC LINE cycle ? Set value (SV) ? Mode Key ? Up Key Timeshare cycle ? Shift Key control 50 % of control output cycle ? Down Key Control output cycle ? Model Information ? Process value (PV) Display the current temperature in the operation screen Parameter composition ? Set value (SV) Display the set temperature in the operation screen change the operation screen, increase the set value, move ? Up Key to the parameter setting mode + 2 sec Operation ? Down Key Decrease the set value, move to the parameter setting mode mode + 2 sec •Shift to the set value digits User setup mode Operator setup mode ? Shift Key •Move from operation screen - users •Move from operator - setting mode + *1 •Move from operation screen - users 2 sec 2 sec ? Mode Key •Move from operator - setting mode +2 sec Light ON with the PID auto tuning Light ON with the control output operation Operation ? Light ON with the Alarm1 operation indicators Light ON with the Alarm2 operation Light ON with the Loop break alarm operation Main function explanation - PID auto tuning (A.T) function Auto tuning function measures, computes and sets the optimum PID or ARW constant automatically. After supplying power in and while temperature is increasing, press the set key and key synchronously for 2 sec. to begin the auto tuning. When auto tuning is finished, tuning operation will be ended automatically. - display When input break (sensor break) occurs or exceeds the maximum temperature range, will be displayed in the measured value displaying unit. - Alarm ? Using the alarm AX series supports 2 independent alarms (AL1 and AL2). These alarms can allocate AL1 or AL2 signal in the RLY1, RLY2 and RLY3 and be used. If alarm signal is not allocated in the RLY1 to RLY3 then the menu related to the alarm will not be displayed. ? Alarm hold action If there is no standby action function, supply the power in then the LOW alarm will become ON while temperature is increasing. In order to prevent the low alarm to become ON during temperature is increasing, add the standby action function so from the point when supplying in the power to until the value goes beyond the set value, it can prevent the low alarm to be operated. - Operation mode Manual reset 0.0 ~ 100.0 % With P control Supplying in the power after finish wiring will display the current temperature. Pressing the Control hysteresis EUS 0 ~ 100 % (Temperature unit) With ON/OFF control key will display the set temperature and output amount alternatively on the set value (SV) Output amount displaying unit. 0 ~ 100 % At all times with input break : Not using - User setup mode When output : Alarm 1 output User setup mode is the setting mode that sets the set value that is changed by users selection is 1 or 2 Relay 1 property and is not frequently such as alarm set value and loop break alarm (LBA). It made the parameter of user : Alarm 2 output R LY setup mode to be displayed on the operator setup mode that allows users to set easily : LBA output (divided the setting level). : Not using : Alarm 1 output - SV setting Relay 2 property At all times ? In Operator Setup Mode, When the value of parameter is , you can change the : Alarm 2 output value with , , and press the key to set up. : LBA output ? In operator Setup Mode, When the value of is , you can change the value in parameter with , , and Press key to set up. : Not using : Alarm 1 output At all times Symbol Display Default Relay 3 property Lists Information (Option) (PV) condition value (SV) : Alarm 2 output : LBA output set temperature EU 0 ~ 100 % at all times EU 0% : Not using Alarm 1 low value EU 0% Alarm 1 mode ---[ (Alarm 1 or 2) ---[ : High alarm Alarm 1 high value EU 100% ]--- : Low alarm When EU 0 ~ 100 % or Alarm 2 mode Alarm 1 dead zone EUS 0% RLYn -[]- : Alarm within range ]--- EUS 0 ~ 100 % (Alarm 1 or 2) ALn is Alarm 2 low value EU 0% ]--[ : Alarm not within range (temperature unit) set Alarm 1 type : ABS (Absolute alarm) Alarm 2 high value EU 100% When AL1 or AL2 Alarm 2 type : DEV (Deviation alarm) is set in Alarm 2 dead zone EUS 0% RLY 1, 2, 3 Alarm 1 standby mode : OFF (not using the standby mode) Loop break alarm time 0 ~ 7200 second 480 When Alarm 2 standby mode : ON (using the standby mode) LBA is Loop break alarm temperature 0 ~ 100 ? (?) 2 Alarm 1 delay time set in the 0 ~ 9999 sec R LYn Alarm 2 delay time Loop break alarm dead zone 0 ~ 100 ? (?) 2 Alarm 1 output LOCK : Alarm output return action : NO LOCK function Alarm 2 output LOCK : Alarm output maintain action : Operator setup mode LOCK, at all KEY LOCK 0 : No change SV Change SV on the Auto-tuning prohibited times At all times operation : Change SV : Operator and user setup mode LOCK How to disassemble FND from case - Operator setup mode Operator setup mode is the setting mode that sets the specification of temperature controller ? AX4 ? AX2 when engineer installs it for the first time. Pressing the key and key synchronously in the operation screen or user setup mode will enter into the operator setup and keys one more time for 2 sec will return to the operation screen. Symbol Default Lists Information Display condition (PV) value : K thermocouple (Not display the decimal points) : K thermocouple (Not display the decimal points) : J thermocouple Input condition At all times : R thermocouple : T thermocouple : RTD Pt100 ? ? AX3 Temperature unit ? / ? option At all times ON (YES) Decimal point Select decimal point OFF (NO) Input compensation -100 ~ 100 (sensor input value + BIAS) At all times Input filter time 0 ~ 120 sec At all times High setting limitation EU 0 ~100 % At all times Low setting limitation EU 0 ~100 % At all times : SSR operating voltage pulse output When output Control output type selection 1 or 2 : Relay output ? AX7 ? AX9 : Timeshare proportional control Voltage pulse When selected SSR output type control output : SSR phase control (continuously proportioning) Control output When is CYC 0 ~ 1000 sec cycle or is RLY : Reverse action (heating control) Control output At all times action : Direct action (cooling control) : P.I.D control Control type : P control (proportional control) At all times : ON / OFF control Proportional band 1 (0.1) ~ EUS 100 % When it is not ON/OFF control Integral time 0 ~ 3600 sec With PID control Derivative time 0 ~ 3600 sec With PID controlDimension and panel cutout, connection diagram [unit : ?] AX2 ? Dimension ? Panel cutout ? Connection diagram AX2 AX2-B AX3 ? Dimension ? Panel cutout ? Connection diagram AX3 AX3-B AX4 ? Dimension ? Panel cutout ? Connection diagram AX4 AX7 ? Dimension ? Panel cutout ? Connection diagram AX7 AX7-B AX9 ? Dimension ? Panel cutout ? Connection diagram AX9 AX9-B
    E-endustri.com'u takip edin
    e-endustri.com Hesaplı Alışveriş Kredi kartları