K3HB-HTA
  • K3HB-HTA
Marka: Omron

Seri:K3HB SERİSİ DİGİTAL PANELMETRELER

Model: K3HB-HTA

Model Birim Fiyat Birim Fiyat Adet Stok
K3HB-HTA100-240VAC Giriş Pt100 ve ThermocoupleFiyat Sorunuz: 0212 320 36 50
  • Ürün Hakkında
  • Dokümanlar
  • Yazılımlar
*48 X 96 X 95mm boyutlar
*Teaching ( öğretme ) fonksiyonu
*100-240VAC ya da 12-24VDC besleme gerilimi
*Opsiyonel çıkış kartları
*DeviceNet desteği
*Ölçekleme Fonksiyonu
*Renk değiştiren ekran ile prosesi kolay izleme
*Arttırılmış görünürlük
*Farklı prosesler için 7 farklı model
*Tek tuş ile değer görüntüley


    --------------------1830545.pdf-----------------
    ¦¦ Solid-state Twin Timers H3CR-F CSM_H3CR-F_DS_E_1_5 DIN 48 × 48-mm Twin Timers • Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of long ON- or OFF-time and short OFF- or ON- time settings are possible. Sixteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h depending on the model to be used. Models with a flicker ON start or flicker OFF start are available. Easy sequence checks through instantaneous outputs for a zero set value at any time range. Length, when panel-mounted with a Socket, of 80 mm or less. 11-pin and 8-pin models are available. Model Number Structure Model Number Legend H3CR - F @ @ - @ @ 1 23 4 5 1. Classification 3. Twin Timer Mode 5. Supply Voltage F: Twin timers 100-240AC: 100 to 240 VAC None: Flicker OFF start 24AC/DC: 24 VAC/VDC N: Flicker ON start 2. Configuration 12DC: 12 VDC 4. Time Range None: 11-pin socket 48-125DC: 48 to 125 VDC 8: 8-pin socket None: 0.05 s to 30 h models 300: 1.2 s to 300 h models Ordering Information List of Models Operating Supply 0.05 s to 30 h models 1.2 s to 300 h models modes voltage 11-pin models 8-pin models 11-pin models 8-pin models Flicker OFF 100 to 240 VAC H3CR-F 100-240AC H3CR-F8 100-240AC H3CR-F-300 100-240AC H3CR-F8-300 100-240AC start 24 VAC/DC H3CR-F 24AC/DC H3CR-F8 24AC/DC H3CR-F-300 24AC/DC H3CR-F8-300 24AC/DC 12 VDC H3CR-F 12DC H3CR-F8 12DC H3CR-F-300 12DC H3CR-F8-300 12DC 48 to 125 VDC H3CR-F 48-125DC H3CR-F8 48-125DC H3CR-F-300 48-125DC H3CR-F8-300 48-125DC Flicker ON start 100 to 240 VAC H3CR-FN 100-240AC H3CR-F8N 100-240AC H3CR-FN-300 100-240AC H3CR-F8N-300 100-240AC 24 VAC/DC H3CR-FN 24AC/DC H3CR-F8N 24AC/DC H3CR-FN-300 24AC/DC H3CR-F8N-300 24AC/DC 12 VDC H3CR-FN 12DC H3CR-F8N 12DC H3CR-FN-300 12DC H3CR-F8N-300 12DC 48 to 125 VDC H3CR-FN 48-125DC H3CR-F8N 48-125DC H3CR-FN-300 48-125DC H3CR-F8N-300 48-125DC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-F 100-240AC Supply voltage 1 ¦ H3CR-F Accessories (Order Separately) Adapter, Protective Cover and Hold-down Clip Name/specifications Models Flush Mounting Adapter Y92F-30 Y92F-73 *1 Y92F-74 *1 Protective Cover Y92A-48B *2 Hold-down Clip For PF085A Socket Y92H-8 (Sold in sets of two) For PL08 and PL11 Sockets Y92H-7 Note: Refer to H3CR-A datasheet for details. *1 The Y92F-48B Front Cover and the Y92P-48G@ Panel Cover cannot be used at the same time. *2 The Y92F-48B Front Cover is made from hard plastic. Remove the Front Cover to change the set value. The Y92F-48B Front Cover and the Y92F-73/-74 Flush Mounting Adapter also cannot be used at the same time. Sockets Timer Round Sockets Pin Connection Terminal Models 11-pin Front Connecting DIN track mounting P2CF-11 DIN track mounting P2CF-11-E (Finger-safe type) Back Connecting Screw terminal P3GA-11 Solder terminal PL11 Wrapping terminal PL11-Q PCB terminal PLE11-0 8-pin Front Connecting DIN track mounting P2CF-08 DIN track mounting P2CF-08-E (Finger-safe type) DIN track mounting PF085A Back Connecting Screw terminal P3G-08 Solder terminal PL08 Wrapping terminal PL08-Q PCB terminal PLE08-0 Note: 1. The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 2. The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection. 3. For details, refer to Socket and DIN Track Products. Terminal Cover Application Model Remarks For back connecting socket Y92A-48G For P3G-08 and P3GA-11 Note: For details, refer to Socket and DIN Track Products. 2¦¦¦ H3CR-F Specifications General Item H3CR-F H3CR-F8 H3CR-FN H3CR-F8N Operating mode Flicker OFF start Flicker ON start Pin type 11-pin 8-pin 11-pin 8-pin Operating/Reset method Time-limit operation/Time-limit reset or self-reset Output type Relay output (DPDT) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. Time Ranges 0.05 s to 30 h Models Time unit s (sec) ×10 s (10 sec) min (min) h (hrs) Setting 1.2 0.05 to 1.2 1.2 to 12 0.12 to 1.2 3 0.3 to 3 3 to 30 0.3 to 3 12 1.2 to 12 12 to 120 1.2 to 12 30 3 to 30 30 to 300 3 to 30 Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. 1.2 s to 300 h Models Time unit ×10 s (10 sec) ×10 min (10 min) h (hrs) ×10 h (10 hrs) Setting 1.2 1.2 to 12 1.2 to 12 0.12 to 1.2 1.2 to 12 3 3 to 30 3 to 30 0.3 to 3 3 to 30 12 12 to 120 12 to 120 1.2 to 12 12 to 120 30 30 to 300 30 to 300 3 to 30 30 to 300 Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. Ratings Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC Operating voltage range 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models Power reset Minimum power-opening time: 0.1 s Power consumption 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC 24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC approx. 1 W at 24 VDC 48 to 125 VDC: approx. 1.5 W at 125 VDC 12 VDC: approx. 1 W at 12 VDC Control outputs Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos? = 1) Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model. 2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor. 3¦ H3CR-F Characteristics Accuracy of operating ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) time Setting error ±5% FS ±50 ms max. Reset time 0.1 s max. Reset voltage 10% max. of rated voltage Influence of voltage ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) Influence of temperature ±1% FS max. (±1% FS ±10 ms max. in ranges of 1.2 and 3s) Insulation resistance 100 M? min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) Impulse withstand 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC voltage 1 kV for 12 VDC, 24 VAC/DC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to 125 VDC 1.5 kV for 12 VDC, 24 VAC/DC Noise immunity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±400 V for 12 VDC Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions 2 Shock resistance Destruction: 980 m/s three times each in six directions 2 Malfunction: 98 m/s three times each in six directions Ambient temperature Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note) EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Light Gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight Approx. 100 g Note: Refer to the Life-test Curve. 4¦¦¦¦ H3CR-F Life-test Curve 10,000 5,000 1,000 Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos? = 1) 30 VDC L/R = 7 ms 500 and a maximum current of 0.1 A can be switched if L/R is 7 ms. In 250 VAC/30 VDC both cases, a life of 100,000 operations can be expected. (cos? = 1) The minimum applicable load is 10 mA at 5 VDC (failure level: P). 100 250 VAC (cos? = 0.4) Load current (A) Connections Block Diagrams Zero setting ON indicator OFF indicator detection circuit Indicator circuit ROM RAM Clock Output circuit Power supply Time range/unit AC (DC) input One-chip microcomputer circuit selectors I/O Functions Inputs --- Outputs Control output Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob. Terminal Arrangement H3CR-F8 H3CR-F H3CR-F8N H3CR-FN H3CR-F8-300 H3CR-F-300 H3CR-F8N-300 H3CR-FN-300 (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. 5 3 Switching operations (x 10 )¦ H3CR-F Operation Timing Chart tON: ON set time tOFF: OFF set time Operating mode Timing chart 0.1 s min Flicker OFF start ON Power OFF tOFF tON tOFF tON tOFF tOFF Lit ON indicator Not lit Lit OFF indicator Not lit Output NO ON OFF Output NC ON OFF Flicker ON start 0.1 s min. Power ON OFF tON tOFF tON tOFF tON tOFF ON indicator Lit Not lit OFF indicator Lit Not lit Output NO ON OFF Output NC ON OFF Note: 1. The reset time requires a minimum of 0.1 s. 2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Nomenclature OFF indicator (green) OFF-time unit display window Lit when the output is OFF. OFF-time unit selector (select one from sec. ON indicator (orange) 10 s, min., and hrs, or from 10 s, 10 min, hrs, Lit when the output is ON. and 10 h) Scale range display windows ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting Time range selector (select one from 1.2, 3, 12, and 30 at full ON-time unit display window scale) For both ON-time and OFF-time. ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h) 6H3CR-F Dimensions Note: All units are in millimeters unless otherwise indicated. H3CR-F 17.4 66.6 H3CR-FN 48 5.7 52.3 0.7 6 H3CR-F-300 H3CR-FN-300 37 dia. 44.8 × 44.8 48 14 dia. R1.3 11 pins 17.4 66.6 H3CR-F8 48 5.7 52.3 0.7 H3CR-F8N 6 H3CR-F8-300 H3CR-F8N-300 37 dia. 44.8 × 44.8 48 14 dia. R1.3 8 pins Dimensions with Front Connecting Socket Dimensions with Back Connecting Socket P2CF-08-@/P2CF-11-@ P3G-08/P3GA-11 81.5 81.5 17.4 17.4 80 75 H3CR-F H3CR-F8 H3CR-FN H3CR-F8N 92.3* 90.0 103.2* 100.9 H3CR-F H3CR-F8 H3CR-FN H3CR-F8N P3GA-11 P3G-08 Y92F-30 Y92F-30 (When (When 2.3* 2.3* Y92A-48G Y92A-48G P2CF-11 P2CF-08 mounted) mounted) P2CF-11-E P2CF-08-E *These dimensions vary with the kind of DIN track (reference value). ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 7Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: ? Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. ? Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.
    E-endustri.com'u takip edin
    e-endustri.com Hesaplı Alışveriş Kredi kartları