--------------------EPDUCAT_0312.pdf-----------------
Eaton.com/epdu
Eaton ePDU
Product Catalog
Switch N to Eaton.2 eaton corporation Enclosure Power Distribution UnitsTable of Contents
Table of contents
Product line overview ................................................................................................................................................................................... 4
Choosing ePDU technologies ...................................................................................................................................................................... 5
Understanding ePDU technologies ............................................................................................................................................................. 6
ePDU software options.................................................................................................................................................................................. 9
Data Center ePDU units ............................................................................................................................................................................... 10
Designed specifically for data centers and IT environments, Eaton’s Data Center ePDUs range
from basic power distribution to the ability to monitor and manage power consumption
Basic ePDUs ................................................................................................................................................................................. 10
Provides reliable and cost-effective power distribution
FlexPDUs and Hot Swap Maintenance Bypass. ................................................................................................................... 14
Increase power distribution from a single UPS / Enables easy UPS replacement
without interruption to the connection load
Monitored ePDUs ......................................................................................................................................................................... 16
Remotely monitors the current draw of the unit and individual sections
Advanced Monitored ePDUs ..................................................................................................................................................... 19
Provides outlet level monitoring for capacity planning and energy management
Switched ePDUs .......................................................................................................................................................................... 20
Provides remote power monitoring of both voltage and current and provides
outlet-level control for on/off/reboot capabilities
Managed ePDUs .......................................................................................................................................................................... 22
Monitors and controls critical factors such as voltage, current and power
factor down to the individual outlet
Eaton Automatic Transfer Switches ......................................................................................................................................... 25
Automatically transfers power from the primary source to the secondary source
Industrial ePDUs ........................................................................................................................................................................................... 27
Frequently used in test and measurement applications, many of Eaton’s Industrial ePDUs
are designed to be controlled with Remote Emergency Power Off
Rack Power Module .................................................................................................................................................................................... 41
Delivers up to 36 kW of power to loads of various voltages, power cords and layouts
ePDU plugs and receptacles ...................................................................................................................................................................... 42
Power cables and accessories ................................................................................................................................................................. 43
Space-saving mounting options ................................................................................................................................................................ 44
Cable restraint and management .............................................................................................................................................................. 45
Racks and airflow management ................................................................................................................................................................ 46
Eaton provides a full line of racks and airflow management solutions to store, cool,
power and secure critical IT equipment
eaton.com/epdu 1.800.356.5794
3Product line overview
Broad product portfolio
® ®
Eaton offers the largest selection of rack mounted power distribution units available on the market, we call these Eaton ePDU units.
Our complete suite of products is designed specifically to help you meet rapidly escalating requirements.
High density power solutions
Eaton offers a number of ePDUs to meet your high power density needs. We offer both rackmount, and vertical mount three-phase
models ranging from 50A to 80A input capacities. These sophisticated units allow an entire rack of equipment to be powered from a
single power cord input.
24x7 reliability through circuit breakers
ePDUs use individual UL-rated branch circuit breakers that protect load segments (outlet groups), ensuring that an overloaded circuit does
not affect other load segments, therefore increasing reliability. Typically, circuit breakers have flat rockers or are fully shrouded to prevent
accidental on/off operation.
Rugged design for optimal performance and quick installation
Eaton ePDUs are designed to meet global safety standards. These units are engineered with rugged construction, have flexible mounting
options, and multiple features ensuring the highest quality and customer satisfaction. Eaton engineers unique solutions for the most
power intense environments.
Interact with our ePDUs online!
Please visit eaton.com/epdu to interact with different ePDU technologies. These tools provide you with an in-depth look of the
technology of the units, plugs, receptacles and much more!
4 eaton corporation Enclosure Power Distribution Units
Product line overviewChoosing ePDU technologies
Choosing ePDU technologies
Eaton ePDU product search wizard makes it easy!
On eaton.com/epdu, Eaton’s product search wizard is a simple interface that allows you to search over 1,000 products for the perfect
solution. You can explore features, benefits and learn basic fundamentals of ePDUs, as well as interact with live demos. This search
wizard allows you to filter ePDUs by:
• Input plug
• Output receptacle
• Power rating
• Function
• TAA compliance
The live search wizard walks you through power requirements and allows you to pick from specific ePDU inventories. Making the right
decisions from the start can make a difference in the dependability and efficiency of an infrastructure. If you need help or have questions
with a selection, you can use the live chat icon or call one of the listed support numbers on our website.
Eaton’s complete offering of ePDU products in the search wizard and in this catalog are designated as either:
Top seller ePDUs - Eaton’s most popular units
Build-to-order ePDUs - Specialized units
Custom ePDUs - Fully engineered unique configurations built to meet your desired solution
Eaton ePDU catalog numbering system
Eaton’s smart style numbers help you understand our numbering system. Follow the example below to see what the letters and numbers
mean within this ePDU catalog. Please note that this numbering scheme represents the majority of our part numbers, but not all.
PW 1 04 BA 0U 006
Unique three-digit model identifier
Branding
001-999 Unique for every model
PW = Eaton style number
Note that alphas signify international
style numbers
Form factor
Input phase
OU, 1U, 2U
1 = Single- / Split-phase
3 = Three-phase
Function / communications
Max kW rounded
BA = Basic
MI = Ethernet Monitored
Two characters, 01- 23
SW = Switched
AM = Advanced Monitored
Eaton has introduced new part numbers to our product portfolio. Please see details below:
ePBZ eMA eAM
BZ = Basic MA = Managed AM = Advanced Monitored
eaton.com/epdu 1.800.356.5794
5Understanding ePDU technologies
Eaton’s ePDU technologies satisfy the demand of every data center. Eaton ePDUs offer single and dual chassis, five technology options,
the broadest power range in the market and the ability to manufacture custom ePDUs. They also offer an arrangement of outlets (number
and type) for every region.
Eaton ePDUs are distinguished for their quality, dependability and versatility. All products are designed for a specific application with an
emphasis on safety and reliability. The Eaton line includes an extensive range of vertical, zero U products, which do not occupy server
space in racks, as well as 1U and 2U formats. Environmental monitoring options are also available.
Monitored Advanced Automatic
Basic Network Monitored Switched Managed Transfer
Feature (BA) (MI) (AM) (SW) (MA) (AT)
Rugged Construction
3 3 3 3 3 3
Horizontal Products
3 3 3 3
Vertical Products
3 3 3 3 3
Local Current Display
3 3 3 3
Current Monitoring Type Section Outlet Section Outlet
Voltage Monitoring
3 3
Serial Interface
3 3
Ethernet Interface
3 3 3 3
*
Environmental Sensors
3 3 3 3
*Available on some models
Industrial ePDUs
Frequently used in test and measurement applications, Eaton offers a variety of Industrial ePDU options, many which are designed to be
controlled with Remote Emergency Power Off. Eaton offers a full range of products with this feature from basic North American models
to 3-Phase international units. Use your own switches or simply plug-in our Remote Control Panel (RCP) into an ePDU.
For more information on Eaton’s line of Industrial
ePDUs, refer to pages 27-40.
6 eaton corporation Enclosure Power Distribution Units
Understanding ePDU technologiesUnderstanding ePDU technologies
Basic (BA) – rugged construction and flexible mounting options (page 10)
Designed for reliable and cost-effective power distribution, Basic ePDUs have the form factor and
receptacle choices to meet the needs of the demanding data center architect. With power levels
ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application.
FlexPDUs and Hot Swap Maintenance Bypass (page 14)
The Eaton FlexPDUs provide flexible output receptacle options from a single UPS. These products
have a three-foot input cord, enabling them to be mounted in close proximity to the UPS.
Ideal for maintenance and UPS replacement, the Eaton Hot Swap Maintenance Bypass facilitates
hot-swappable UPS replacement without shutting down equipment connected to the UPS.
Monitored Network (MI) (page 16)
Eaton Monitored ePDUs provide remote monitoring of the current draw of individual sections via
Ethernet or serial communication. This capability, combined with state-of-the-art software allows
you to aggregate the information from hundreds of ePDUs in one location. All Monitored ePDUs also
include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers.
Advanced Monitored (AM) – Current Monitoring Per Outlet (page 19)
Eaton Advanced Monitored ePDUs provide high accuracy monitoring for high-density, mission-critical
server applications. By monitoring power consumption and energy trends at the outlet level, you are
able to truly manage your data center. Integrated with Eaton’s management software, you can monitor
these units from any computer on the network. The new advanced LCD display provides outlet and
section current information, voltage and kilowatt-hour readings, all at a single glance.
Switched (SW) – individual outlet switching and sequencing (page 20)
Designed for data centers needing remote site management, the Switched ePDUs provide remote
power monitoring of both voltage and current. The current is also displayed on a local two-digit
current meter. These units also monitor both temperature and humidity.
Managed (MA) (page 22)
Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current
and power factor. This level of information allows you to make the right decision when it comes to
energy consumption in your data center. You can also control the power at the individual outlet level,
switching it on, off or rebooting it. Integrated with Eaton’s management software, you can control
these units from any computer on the network server. The new advanced LCD display provides outlet
and section current information, voltage add kilowatt-hour readings, all at a single glance.
Eaton Automatic Transfer Switches (AT) (page 25)
Designed for switching non phase synchronized AC power sources, the automatic transfer switch
ePDUs intelligent circuitry monitors both inputs, providing a fast switch transfer from primary to
secondary source power critical equipment without interruption. These ePDUs assure the highest
level of redundancy to mission-critical applications.
eaton.com/epdu 1.800.356.5794
7Why monitor?
The unique monitoring function of Eaton ePDUs allows you to remotely monitor the current draw of individual outlets or sections over
a network. This, combined with state-of-the-art software, allows the user to aggregate the information from hundreds of ePDUs in one
location. All monitored ePDUs also include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers. This feature
allows remote monitoring of current for capacity planning and energy management.
Key features and benefits
• Access circuit-level and ePDU-level information worldwide
®
• Get a global view across your ePDUs from any PC or server with Intelligent Power Manager software
(you can learn more about Intelligent Power Manager on page 9)
• Receive warnings and alarms remotely
Advanced Monitoring
Advanced monitoring allows you to monitor down to the individual outlet.
Key features:
• Monitor power consumption in kilowatt hours at the individual outlet level requirement
• Readings available via Ethernet connection over a network (utilizing Eaton’s Intelligent Power Manager software)
• Power consumption readings allow for power usage effectiveness (PUE) calculations
• Easy-read LCD screen reduces local monitoring time
• UL Listed (UL489) branch circuit breakers meet industry requirements
• Cisco EnergyWise Certified– Eaton’s new ePDUs are Cisco EnergyWise Certified
400-volt solution
Eaton 400V ePDUs limit energy loss through transformers by avoiding the 480-208V conversion. These units use European standard,
three-phase 400V phase-to-phase and 230V phase-to-neutral to replace 208V phase-to-phase in the U.S. Operating power supplies at
230V versus 208V typically increases power supply efficiency.
400V ePDUs also distribute almost twice the power on the same copper to achieve multiple reductions. Eaton offers a unique power
distribution solution for 400V applications. These applications include:
• Containerized data centers
• Customers looking for global standard
• Progressive data centers looking for cost reductions and efficiency gains
You can find 400V ePDUs featured in the Monitored, Switched and Managed sections of this catalog, as well as on eaton.com/epdu.
400V ePDU part numbers (for reference)
Monitored Switched Managed
• VPC2864-3861 • IPV70U1-EP1-09L • eMA013
• VPC2864-3862 • IPV70U2-EP1-09L • eMA014
8 eaton corporation Enclosure Power Distribution Units
Understanding ePDU technologiesePDU software options
ePDU software options
Eaton offers a number of software management tools for you based on the number of ePDUs you need to manage.
Rack Quantity
Software Best Supported Type of Software Application Cost
Data Closet
Included requires
Web Browser / Email 1-25 Small Network Included
web browser
Stand Alone
Integrates to Small to Large
SNMP 1-1000 Low-High
Third party software Enterprise
Eaton software Small to Medium
IPM 1-200 Low-Medium
free to try Enterprise
Eaton enterprise Facility or Large
®
Power Xpert 100-1000 High
solution Enterprise
Web browser / email alerts
Every network connected ePDU comes standard with built-in web server and email alert capability. To connect to any ePDU using
a standard web browser to configure, monitor and control. If your network allows connection to an SMTP server, the ePDU can be
configured to send email alerts using a Post Office Protocol 3 email account.
SNMP
Every network-connected ePDU supports SNMP alerts and has a standard MIB available for integration into third party software
solutions. SNMP supports full monitoring and control with read/write capability for all major variables.
Cisco EnergyWise certification
Cisco EnergyWise certification confirms Eaton’s dedication to engineering quality IT products and speaks to the importance of power
consumption and measurement in today’s data center space. With Eaton ePDUs and Cisco Energywise Software you can monitor voltage,
frequency, amps and watts for each receptacle on your network (available with Advanced Montiored and Managed ePDUs).
Intelligent Power Manager (IPM)
Eaton’s Intelligent Power Manager software integrates seamlessly with our ePDUs,
giving you the tools you need to monitor and manage the power in your data center
environment. You can also measure power consumption and kWH, which will help you
calculate power usage effectiveness of the devices attached. Better yet, our software is
fully compatible with the most popular management platforms in the industry, including
VMware, Microsoft and Citrix. Our software is free of charge for up to 10 nodes.
Download and learn more today at eaton.com/intelligentpowermanager.
Eaton’s IPM dashboard allows you to easily
monitor your network
Power Xpert software
Ideal as a facility enterprise solution, Power Xpert supports the full offering of Eaton’s electrical products and offers support for third-
party products. Power Xpert monitors alarms, logs current readings and environmental sensors on ePDU. There is a web-based dashboard
view that allows you to drill down to a specific ePDU. Using the optional reporting package, it can generate customized power utilization
reports.
Power Xpert also allows you to customize the conditions under which alarms are triggered and can run deployment validation tools
during installation so all key setup requirements are automatically validated. To learn more, please visit eaton.com/pxs.
eaton.com/epdu 1.800.356.5794
9Basic ePDUs - 0U
Eaton Basic ePDUs provide reliable and cost-effective power distribution.
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
ePBZ98 ePBZ98 5-15P 15A 1.44 BA 6 0U (18) 5-15R 48.0 x 1.5 x 1.5
ePBZ89 ePBZ89 C14 None 1.44 BA 6 0U (16) C13 28.0 x 1.9 x 2.2
ePBZ75 ePBZ75 5-15P None 1.44 BA 15 0U (14) 5-15R 23.9 x 1.5 x 1.5
ePBZ73 ePBZ73 5-15P (1) 15A 1.44 BA 15 0U (18) 5-15R 48.0 x 1.5 x 1.5
ePBZ97 ePBZ97 5-20P (1) 20A 1.92 BA 6 0U (24) 5-20R 60.0 x 1.5 x 1.5
ePBZ96 ePBZ96 L5-20P (1) 20A 1.92 BA 6 0U (24) 5-20R 60.0 x 1.5 x 1.5
ePBZ74 ePBZ74 L5-20P/5-20P None 1.92 BA 15 0U (14) 5-20R 23.9 x 1.5 x 1.5
ePBZ72 ePBZ72 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (18) 5-20R 48.0 x 1.5 x 1.5
ePBZ77 ePBZ77 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (24) 5-20R 60.0 x 1.5 x 1.5
ePBZ71 ePBZ71 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (30) 5-20R 72.0 x 1.5 x 1.5
ePBZ90 ePBZ90 L5-30P (2) 20A 2.88 BA 15 0U (24) 5-20R 40.0 x 1.9 x 2.1
PW103BA0U257 V70BC2-N-SL-009 L5-30P (2) 20A 2.88 BA 9 0U (24) 5-20R 66.0 x 2.0 x 1.89
(20) C13,
ePBZ93 ePBZ93 L6-20P (1) 20A 3.33 BA 6 0U 42.0 x 1.9 x 2.4
(4) C19
PW103BA0U237 V70NB4-N-SL-009 L6-20P None 3.33 BA 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89
ePBZ93 ePBZ93 L6-20P None 3.33 BA 10 0U (20) C13, (4) C19 40.0 x 1.9 x 2.2
(20) C13,
ePBZ92 ePBZ92 L6-30P (2) 20A 4.99 BA 6 0U 42.0 x 1.9 x 2.2
(4) C19
PW105BA0U239 V70BF5-N-SL-009 L6-30P (2) 20A 4.99 BA 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89
PW105BA0U412 LPC1224-1P L14-30P (6) 15A 4.99 BA 6 0U (12) 5-15R 10.0 x 7.75 x 3.0
ePBZ80 ePBZ80 L6-30P (2) 20A 4.99 BA 10 0U (30) C13, (6) C19 52.9 x 1.9 x 2.2
PW306BA0U241 VPC2864-A2-3846 L21-20P None 5.76 BA 9 0U (30) 5-20R 66.0 x 2.0 x 1.89
PW306BA0U244 VPC2864-3850 L21-20P None 5.76 BA 9 0U (36) C13, (6) C19 66.0 x 2.0 x 1.89
(18) 5-20R,
PW306BA0U246 VPC2864-3856 L21-20P None 5.76 BA 9 0U 66.0 x 2.0 x 1.89
(6) L6-20R
PW309BA0U409 VPC3106-C2-15 L21-30P (3) 20A 8.65 BA 9 0U (24) 5-20R 70.0 x 2.0 x 3.8
(2) 20A (24) C13, (4) C19,
PW314BA0U251 VPC2864-3858 CS8365 14.4 BA 9 0U 66.0 x 2.0 x 1.89
(1) 30A (2) L6-30R
PW314BA0U253 VPC2864-3853 CS8365 (3) 20A 14.4 BA 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89
10 eaton corporation Enclosure Power Distribution Units
Basic ePDUsBasic ePDUs
ePBZ89 ePBZ97 ePBZ93 PW105BA0U239 PW306BA0U244 PW314BA0U253
eaton.com/epdu 1.800.356.5794
11Basic ePDUs - 1U
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
PW101BA1U140 T982A1-N-SS-009 5-15P (1) 15A 1.44 BA 9 1U (12) 5-15R 1.75 x 19.0 x 7.0
ePBZ86 ePBZ86 5-15P None 1.44 BA 10 1U (12) 5-15R 1.7 x 17.3 x 2.3
ePBZ83 ePBZ83 5-15P None 1.44 BA 15 1U (12) 5-15R 1.7 x 17.3 x 2.3
PW102BA1U158 T982A2-N-SS-009 5-20P (1) 20A 1.92 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
ePBZ99 ePBZ99 L5-20P (1) 20A 1.92 BA 6 1U (12) 5-20R 1.75 x 19 x 2.4
PW102BA1U159 T982A2-N-SL-009 L5-20P (1) 20A 1.92 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
ePBZ85 ePBZ85 5-20P None 1.92 BA 10 1U (12) 5-20R 1.7 x 17.3 x 2.3
1
ePBZ82 ePBZ82 L5-20P/5-20P None 1.92 BA 15 1U (12) 5-20R 1.7 x 17.3 x 2.3
PW103BA1U190 T982C2-N-SL-009 L5-30P (2) 20A 2.88 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
ePBZ84 ePBZ84 L5-30P (2) 20A 2.88 BA 10 1U (10) 5-20R 1.7 x 17.0 x 3.5
ePBZ78 ePBZ78 L5-30P (2) 20A 2.88 BA 15 1U (20) 5-20R 1.7 x 17.0 x 3.5
ePBZ88 ePBZ88 C20 None 3.33 BA 6 1U (10) C13, (2) C19 1.72 x 19.0 x 2.4
PW103BA1U405 TPC2104 C20 (1) 20A 3.33 BA 9 1U (16) C13 1.75 x 19.0 x 7.0
ePBZ95 ePBZ95 L6-20P None 3.33 BA 6 1U (12) C13, (1) C19 1.72 x 19.0 x 2.4
PW103BA1U191 T982B3-N-SL-009 L6-20P (1) 20A 3.33 BA 9 1U (12) C13 1.75 x 19.0 x 7.0
ePBZ94 ePBZ94 L6-30P (2) 20A 4.99 BA 6 1U (6) C19 1.72 x 19.0 x 2.4
PW103BA1U406 TPC2105-1-107 L6-30P (2) 15A 3.33 BA 9 1U (16) C13 1.75 x 19.0 x 7.0
PW105BA1U163 T982F3-N-SL-009 L6-30P (2) 15A 4.99 BA 9 1U (12) C13 1.75 x 19.0 x 7.0
PW105BA1U192 T982F4-N-SL-009 L6-30P (2) 15A 4.99 BA 9 1U (8) C13, (4) C19 1.75 x 19.0 x 7.0
PW105BA1U404 T982G1-N-SL-009 L14-30P (2) 15A 4.99 BA 9 1U (12) 5-15R 1.75 x 19.0 x 7.0
ePBZ91 ePBZ91 L6-30P (2) 20A 4.99 BA 10 1U (10) C13 1.7 x 17.0 x 3.5
ePBZ79 ePBZ79 L6-30P (2) 20A 4.99 BA 15 1U (16) C13, (4) C19 1.7 x 17.0 x 5.1
PW314BA1U193 T17C19250-3-009 CS8365 (6) 20A 14.4 BA 9 1U (6) C19 1.75 x 19.0 x 7.0
1. These units ship with an adapter allowing for 5-20P input plug.
12 eaton corporation Enclosure Power Distribution Units
Basic ePDUsBasic ePDUs
Front view Rear view
PW101BA1U140
ePBZ99
ePBZ88
ePBZ95
ePBZ94
Front view Rear view
PW105BA1U163
Front view Rear view
PW314BA1U193
eaton.com/epdu 1.800.356.5794
13FlexPDUs
Eaton FlexPDUs increase power distribution from a single UPS.
• 3-foot cord allows easy connection close to UPS without cable clutter
• Mounting bracket attaches directly to UPS
• Mounting bracket allows for vertical, 1U or UPS attachment
Hot Swap MBP mounted
in rack with 3U UPS
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
1
(ft) (H x W x D, in)
(12) 5-15R,
EFLX1500R-PDU1U 58015 5-15P None 1.44 BA 3 1U 1.7 x 17.3 x 2.3
(1) C19
EFLX2000R-PDU1U 58020 5-20P None 1.92 BA 3 1U (12) 5-20R 1.7 x 17.3 x 2.3
EFLX2000R-PDU1UL 58021 5-20P None 1.92 BA 3 1U (5) L5-20R 2.0 x 17.3 x 3.0
EFLXI3000R-PDU1UIEC 68438 C20 Inlet (2) 20A 3.33 BA 3 1U (12) C13, (1) C19 1.7 x 17.3 x 2.3
1. Includes C19 to C14 and C19 to C20 jumper cables
Hot Swap Maintenance Bypass
Hot Swap MBPs enable easy UPS replacement without interruption to the connected load. Placing the Hot Swap MBP in bypass mode
provides utility power to equipment while the UPS is being serviced.
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
EHBPL1500R-PDU1U 58115 5-15P None 1.44 BA 8 2U (6) 5-15R 2.1 x 17.3 x 3.8
EHBPL2000R-PDU1U 58120 5-20P None 1.92 BA 8 2U (6) 5-15R 2.1 x 17.3 x 3.8
EHBPL3000R-PDU1U 58130 L5-30P (2) 20A 2.88 BA 3.3 2U (5) 5-20R 2.1 x 17.3 x 3.8
14 eaton corporation Enclosure Power Distribution Units
FlexPDUs and Hot Swap Maintenance BypassFlexPDUs and Hot Swap Maintenance Bypass
FlexPDU mounted with 2U UPS
EFLX1500R-PDU1U
EFLX2000R-PDU1UL
EFLXI3000R-PDU1UIEC
EHBPL3000R-PDU1U
eaton.com/epdu 1.800.356.5794 15Monitored ePDUs - 0U
Eaton Monitored ePDUs enable you to remotely monitor the current draw of the unit and individual sections.
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
PW101MI0U233 V70NA1-N-SS-109 5-15P None 1.44 MI 9 0U (24) 5-15R 66.0 x 2.0 x 1.89
PW102MI0U234 V70NA2-N-SS-109 5-20P None 1.92 MI 9 0U (24) 5-20R 66.0 x 2.0 x 1.89
PW102MI0U235 V70NA2-N-SL-109 L5-20P None 1.92 MI 9 0U (24) 5-20R 66.0 x 2.0 x 1.89
PW103MI0U236 V70BC1-N-SL-109 L5-30P (1) 15A 2.88 MI 9 0U (24) 5-15R 66.0 x 2.0 x 1.89
PW103MI0U238 V70NB4-N-SL-109 L6-20P None 3.33 MI 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89
PW105MI0U240 V70BF5-N-SL-109 L6-30P (2) 20A 4.99 MI 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89
(24) C13, (4) C19,
PW105MI0U255 V70BJ3-N-SL-109 L14-30P (2) 20A 4.99 MI 9 0U 66.0 x 2.0 x 1.89
(4) 5-20R
PW306MI0U242 VPC2864-A2-3847 L21-20P None 5.76 MI 9 0U (30) 5-20R 66.0 x 2.0 x 1.89
(24) C13, (3) C19,
PW306MI0U243 VPC2864-3848 L21-20P None 5.76 MI 9 0U 66.0 x 2.0 x 1.89
(6) 5-20R
PW306MI0U408 VPC2864-A1 L21-20P None 5.76 MI 9 0U (30) 5-15R 66.0 x 2.0 x 1.89
PW306MI0U245 VPC2864-3851 L21-20P None 5.76 MI 9 0U (36) C13, (6) C19 66.0 x 2.0 x 1.89
(18) 5-20R,
PW306MI0U247 VPC2864-3857 L21-20P None 5.76 MI 9 0U 66.0 x 2.0 x 1.89
(6) L6-20R
PW306MI0U416 VPC2864-3436 L21-20P None 5.76 MI 10 0U (42) C13 66.0 x 2.0 x 1.89
(24) C13, (3) C19,
PW309MI0U248 VPC2864-3849 L21-30P (3) 20A 8.64 MI 9 0U 66.0 x 2.0 x 1.89
(6) 5-20R
PW309MI0U250 VPC2864-3726 L21-30P (3) 15A 8.64 MI 9 0U (36) C13 66.0 x 2.0 x 1.89
PW309MI0U256 VPC2864-3852 L21-30P (3) 20A 8.64 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89
(2) 20A (24) C13, (4) C19,
PW314MI0U252 VPC2864-3859 CS8365 14.4 MI 9 0U 66.0 x 2.0 x 1.89
(1) 30A (2) L6-30R
PW314MI0U254 VPC2864-3854 CS8365 (3) 20A 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89
IEC309 (12) C13,
PW317MI0U222 VPC3690 (6) 20A 17.3 MI 7 0U 66.0 x 4.0 x 1.89
460P9W (12) C19
IEC309
400V
VPC2864-3861 VPC2864-3861 None 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.83
516P6W
IEC309
VPC2864-3862 400V VPC2864-3862 (3) 20A 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.83
532P6W
These units have available temperature monitoring.
Optional sensors
SENSOR - T1-10
(1) Temperature sensor, 10’ cable
SENSOR - T2-10
(2) Temperature sensor,
10’ cable each
16 eaton corporation Enclosure Power Distribution Units
Monitored ePDUsMonitored ePDUs
PW306MI0U247 PW309MI0U248 PW309MI0U250 PW317MI0U222
PW309MI0U256
eaton.com/epdu 1.800.356.5794
17Monitored ePDUs - 1U/2U
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
PW101MI1U221 T982A1-N-SS-109 5-15P (1) 15A 1.44 MI 9 1U (12) 5-15R 1.75 x 19.0 x 7.0
PW101MI1U403 T982A2-F-SS-109 5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
PW102MI1U160 T982A2-N-SL-109 L5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
PW103MI1U161 T982C2-N-SL-109 L5-30P (2) 20A 2.88 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0
PW103MI1U162 T982B3-N-SL-109 L6-20P (1) 20A 3.33 MI 9 1U (12) C13 1.75 x 19.0 x 7.0
PW105MI1U164 T982F3-N-SL-109 L6-30P (2) 15A 4.99 MI 9 1U (12) C13 1.75 x 19.0 x 7.0
PW105MI1U165 T982F4-N-SL-109 L6-30P (2) 15A 4.99 MI 9 1U (8) C13, (4) C19 1.75 x 19.0 x 7.0
PW105MI2U402 PC3783 L6-30P (2) 20A 4.99 MI 15 2U (20) C13 3.44 x 19.0 x 7.0
IEC309
PW317MI2U141 PC3623 (6) 20A 17.29 MI 10 2U (12) C19 3.5 x 19.0 x 13.5
460P9W
These units have available temperature monitoring.
Optional sensors
SENSOR - T1-10
(1) Temperature sensor, 10’ cable
SENSOR - T2-10
(2) Temperature sensor,
10’ cable each
Front view Rear view
PW102MI1U160
Front view Rear view
PW103MI1U162
Front view Rear view
PW105MI1U165
Front view Rear view
PW317MI2U141
18 eaton corporation Enclosure Power Distribution Units
Monitored ePDUsAdvanced Monitored ePDUs
Advanced Monitored ePDUs
Eaton Advanced Monitored ePDU provides maximum power for both standard and blade server. Additionally this technology provides
outlet level monitoring for capacity planning and energy management.
Outlet Level Dimensions
1
Catalog Number Monitoring Input Plug Breakers Max kW Orientation Receptacles (H x W x D, in)
2
eAM008 3
L6-20P None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6
eAM001 3
L6-30P (2) 20A 5.8 0U (20) C13, (4) C19 68.0 x 2.2 x 2.6
eAM002 3
L21-20P None 5.8 0U (21) C13, (3) C19 60.0 x 2.2 x 2.6
3
eAM004
L21-30P (3) 20A 8.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6
3
eAM003
CS8365 (3) 20A 12.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6
eAM005 3
IEC 309-460P9W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6
1. 10-ft cord length, all units
2. Detachable cordset, C20 cord is also included; 120V cords are optional. Please see accessories.
Optional sensors
EMP001
Environmental Monitoring
Probe for Advanced
Monitored and Managed
ePDUs
Key technology features
• Outlet-level monitoring
• High accuracy monitoring
• Advanced LCD display
• Flexible mounting
• Color-coded section labeling
eAM008 eAM004 eAM005
eaton.com/epdu 1.800.356.5794
19Switched ePDUs
Eaton switched ePDUs provide remote power monitoring of both voltage and current and provide outlet-level control for
on/off/reboot capabilities.
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
PW101SW0U224 IPV70A1-EP1-09S 5-15P None 1.44 SW 9 0U (16) 5-15R 66.0 x 2.0 x 1.89
PW102SW0U150 IPV42A2-EP1-09L L5-20P None 1.92 SW 9 0U (8) 5-15R 42.0 x 2.0 x 1.89
PW102SW0U151 IPV70A5-EP1-09L L5-20P None 1.92 SW 9 0U (24) 5-15R 66.0 x 2.0 x 1.89
PW103SW0U152 IPV70C5-EP1-09L L5-30P (2) 15A 2.88 SW 9 0U (16) 5-15R 66.0 x 2.0 x 1.89
PW103SW0U153
IPV70B2-EP1-10L L6-20P None 3.33 SW 10 0U (24) C13 66.0 x 2.0 x 1.89
PW105SW0U154 IPV70F3-EP1-09L L6-30P (2) 15A 4.99 SW 9 0U (16) C13 66.0 x 2.0 x 1.89
PW306SW0U155 IPV70K1-EP1-09L L21-20P None 5.76 SW 9 0U (24) 5-15R 66.0 x 2.0 x 1.89
PW306SW0U156 IPV70M1-EP1-09L L21-20P None 5.76 SW 9 0U (24) C13 66.0 x 2.0 x 1.89
PW309SW0U178 IPV70R1-EP1-09L L21-30P (3) 20A 8.64 SW 9 0U (24) C13 66.0 x 2.0 x 3.5
IEC309 (18) C13,
PW317SW0U400 IPV70T2-EP1-12L (6) 20A 17.29 SW 12 0U 66.0 x 2.0 x 4.0
460P9W (6) C19
IEC309 (12) C13,
PW317SW0U401
IPV70T1-EP1-12L (6) 20A 17.29 SW 12 0U 66.0 x 2.0 x 4.0
460P9W (12) C19
IPV70U1-EP1-09L IPV70U1-EP1-09L IEC309 516P6W None 14.4 SW 9 0U (24) C13 66.0 x 2.0 x 1.83
(18) C13,
IPV70U2-EP1-09L IPV70U2-EP1-09L IEC309 516P6W None 14.4 SW 9 0U 70.0 x 2.0 x 4.0
(6) C19
1 2
PW103SW2U413 IPC3401-NET C20 (1) 20A 3.33 SW NA 1U (8) C13 1.7 x 19.0 x 9.5
1 2
PW103SW2U414 IPC3402-NET C20 (1) 20A 3.33 SW NA 1U (8) 5-15R 1.7 x 19.0 x 9.5
(20) C13,
PW105SW2U415 IPC36F4N2USW15L L6-30P (2) 20A 4.99 SW 9 2U 3.5 x 19.0 x 9.5
(4) C19
(20) C13,
PW105SW2U223 IPC36F4N2USW09L L6-30P (2) 20A 4.99 SW 9 2U 3.5 x 19.0 x 9.5
(4) C19
1. Model does not have local or remote current or voltage monitoring but features local on/off buttons in addition to remote switching.
2. Input power cord sold separately.
These units have available temperature monitoring.
Optional sensors SENSOR - T1H1-10
(1) Temperature and humidity
SENSOR - T1-10
sensor, 10’ cable
(1) Temperature sensor, 10’ cable
SENSOR - T2H1-10
SENSOR - T2-10
(1) Temperature and humidity
(2) Temperature sensor,
sensor, 10’ cable
10’ cable each
(1) Temperature sensor, 10’ cable
20 eaton corporation Enclosure Power Distribution Units
Switched ePDUsSwitched ePDUs
PW101SW0U224 PW102SW0U150 PW103SW0U152 PW103SW0U153 PW105SW0U154 PW309SW0U178
eaton.com/epdu 1.800.356.5794
21Managed ePDUs
Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the
individual outlet.
Outlet Level Outlet Level Dimensions
1
Catalog Number Monitoring Switching Input Plug Breakers Max kW Orientation Receptacles (H x W x D, in)
2
eMA012 3 3 L6-20P None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6
eMA006 3 3 L21-20P None 5.8 0U (21) C13, (3) C19 60.0 x 2.2 x 2.6
eMA010 3 3 L6-30P (2) 20A 5.8 0U (20) C13, (4) C19 68.0 x 2.2 x 2.6
eMA011 3 3 L21-30P (3) 20A 8.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6
eMA013 400V 3 3 IEC 309-516P6W None 11.5 0U (12) C13, (12) C19 68.0 x 2.2 x 2.6
eMA007 3 3 CS8365 (3) 20A 12.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6
eMA009 3 3 IEC 309-460P9W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6
400V
eMA014 3 3 IEC 309-532P6W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6
1. 10-ft cord length, all units
2. Detachable cordset, C20 cord is also included; 120V cords are optional. Please see accessories.
Optional sensors
EMP001
Environmental Monitoring Key technology features
Probe for Advanced
• Outlet-level monitoring
Monitored and Managed
• Outlet-level power switching (on/off/reboot)
ePDUs
• High accuracy monitoring
• Advanced LCD display
• Flexible mounting
• Color-coded section labeling
22 eaton corporation Enclosure Power Distribution Units
Managed ePDUsManaged ePDUs
Color-coded receptacles
Advanced LCD display
eMA012 eMA010 eMA009
eaton.com/epdu 1.800.356.5794
23Managed
Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the individual outlet.
Key features:
• Monitor and control power consumption at the outlet level, including on, off and reboot
• Advanced LCD display offers easy user-interface and vast power information
• Single-phase and three-phase configurations provide solutions for SMB and networking closets, large data centers and blade server
applications
• PUE level 3 rating determines high energy efficiency
• Environmental monitoring probe tracks internal and external temperatures, giving you key information to help reduce cooling costs –
needs to be ordered separately
• Cisco EnergyWise Certified– Eaton’s new ePDUs are Cisco EnergyWise Certified
Color-coded receptacles Environmental monitoring
You can utilize the Environmental Monitoring Probe to track
internal and external temperatures, humidity and contact closure.
This information allows you to operate the ePDU up to 50°C
(122° F), in turn reducing cooling costs. (Part number EMP001).
LEDs represent
each outlet
Advanced LCD display
This new advanced LCD display provides outlet and section
current information, voltage and kilowatt-hour readings, all at a
single glance. The display is accompanied with a three-button
Local buttons allow
interface that allows you to navigate through the user-friendly
for easy navigation
menu structure. Dual-color display blinks when a system alarm is of the menu
detected, providing local notification.
Serial port for local configuration
Network management interface
and environmental monitoring,
10/100 Ethernet port for network
connectivity
24 eaton corporation Enclosure Power Distribution Units
Managed ePDUsEaton Automatic Transfer Switches
Eaton Automatic Transfer Switches
The Eaton eATS ePDUs automatically transfer power from the primary source to a secondary source.
Cord Dimensions
Catalog Number Style Number Input Plug Breaker Max kW Function Orientation Receptacles
(ft) (H x W x D, in)
PWATSS515002 T2235-A1-NNB09S (2) 5-15P None 1.44 AT 9 1U (8) 5-15R 1.72 x 19.0 x 7.0
PULSTS1400R-1U 66027 (2) 5-15P None 1.44 AT 6 1U (6) 5-15R 1.72 x 19.0 x 9.8
PWATSS520003 T2235-A2-NNB09S (2) 5-20P None 1.92 AT 9 1U (8) 5-20R 1.72 x 19.0 x 7.0
PWATSL520004 T2235-A2-NNB09L (2) L5-20P None 1.92 AT 9 1U (8) 5-20R 1.72 x 19.0 x 7.0
PWATSL530005 T2235-C2-CNB09L (2) L5-30P (1) 20A 2.88 AT 9 1U (8) 5-20R 1.72 x 19.0 x 9.5
PWATSL530007 T2235-3369 (2) L5-30P (1) 30A 2.88 AT 9 1U (1) L5-30R 1.72 x 19.0 x 7.0
1
PWATSSC20001 T2235-AB-NNBC20 (2) C20 None 1.92 AT NA 1U (8) C13, (1) C19 1.72 x 19.0 x 7.0
PULSTS16AMPR-1U 66028 (2) C20 None 3.33 AT 6 1U (6) C13, (1) C19 1.72 x 19.0 x 9.8
PWATSL630006 T2235-F3-CNB09L (2) L6-30P (2) 15A 4.99 AT 9 1U (12) C13 1.72 x 19.0 x 7.0
PWATSL630008 T2235-3358 (2) L6-30P None 4.99 AT 9 1U (1) L6-30R 1.72 x 19.0 x 7.0
1. Input power cord sold separately.
eaton.com/epdu 1.800.356.5794
25Front view Rear view
PWATSS515002
Front view Rear view
PWATSL530007
Front view Rear view
PWATSSC20001
Front view Rear view
PWATSL630006
26 eaton corporation Enclosure Power Distribution Units
Eaton Automatic Transfer SwitchesIndustrial ePDUs
Intelligent Power Control
Serial
Circuit EMI/RFI Surge Input Ethernet Dimensions
Catalog Number Full Load Receptacles Cord (ft) Control
Breaker Filter Suppression Plug Control (H x W x D, in)
(RS232)
1920 VA @ 120V~ C20
IPC3401 (8) C13 (2) 20A 20A 270V No Yes 1.7 x 19.0 x 9.5
3840 VA @ 240V~ Inlet
1920 VA @ 120V~ C20 Power
IPC3401-NET (8) C13 (2) 20A 20A 270V Yes Yes 1.7 x 19.0 x 9.5
3840 VA @ 240V~ Inlet cables
must be
C20
ordered
IPC3402 1920 VA (8) 5-15R (1) 20A 20A 270V No Yes 1.7 x 19.0 x 9.5
Inlet
separately.
Refer to
C20
IPC3402-NET 1920 VA (8) 5-15R (1) 20A 20A 270V Yes Yes 1.7 x 19.0 x 9.5
page 43
Inlet
for power
C20 cable
IPC3402-A2 1920 VA (8) 5-20R (1) 20A 20A 270V No Yes 1.7 x 19.0 x 9.5
Inlet options.
C20
IPC3402-A2-NET 1920 VA (8) 5-20R (1) 20A 20A 270V Yes Yes 1.7 x 19.0 x 9.5
Inlet
(4) 5-20R, (1) 20A,
IPC3402-2756 2880 VA N/A 270V L5-30P 10 Yes Yes 1.7 x 19.0 x 9.5
(4) 5-15R (1) 10A
(1) 20A,
IPC3402-2930 2880 VA (8) 5-15R N/A 270V L5-30P 10 Yes Yes 1.7 x 19.0 x 9.5
(1) 10A
Please refer to page 43 for power cable assemblies to match your country specific requirements.
(11) Indicator lights Outlet status
• Main power to system-CB on • Query the IPC for Outlet and Watch Dog status
• Individual power on to outlets 1-8
Strapping
• Data acquisition and remote disable
• Strapping allows up to 10 IPCs (80 outlets) to be controlled at
Remote or local control
one address
• Serial RS232 port (DB9 Male) for direct computer or modem • Units are connected together via the RS485 “IN” and “OUT”
connection connectors
• RS485 input/output for strapping up to 10 systems together
Multiple time delay (MTD)
over CAT.5 cable
• Sequence power up and power down to outlets with a one
• Local: one on/off switch for each outlet
second time delay (factory set)
• NET SYSTEMS ONLY: RJ45 for network connections (Ethernet)
• Set power on sequence to any combination of outlets
Remote disable
Set the MTD timing from 1 second to 999 seconds, i.e. 009 = 9
With the push of a button, disable remote access to the IPC when seconds
needed
Software controls
Power supply
• Multi-platform compatible
The IPC3401 series features a full range power supply for • Control via terminal emulation software
operation at 100-240 Vac input/output • Web interface for browser control
EMI/RFI filtering Commands available
• Common mode - line to ground • All outlets on/off or specific outlets on/off
• Differential mode - line to line • Set up and sequence on/off all outlets
• Filtered inlet isolates noise before entering the system • Create password and unit address
• Refer to chart 3 on page 40 • Outlet naming (8 characters)
• IPC3402-2756 and IPC3402-2930 do not have filtering • Set up, enable or disable Watch Dog
• Display outlet and Watch Dog timer status
Spike/surge suppression (TVSS)
• Automatically receive update outlet status whenever there’s a
• Line to line
change
• Refer to chart 1 on page 40
• Auto-reboot outlet 1 with a five-second delay on restart
• Multi-stage, both MOVs and SAPs
eaton.com/epdu 1.800.356.5794
27Intelligent Power Control IPC3600 Series
Ethernet/ Circuit EMI/RFI Surge Input Dimensions
Catalog Number Full Load Receptacles Cord (ft)
Serial Breaker Filter Suppression Plug (H x W x D, in)
Not
1920 VA @ 120V~
IPC3601 Yes (8) C13 (1) 20A 20A Yes C20 Inlet 1.7 x 19.0 x 19.5
3840 VA @ 240V~
Included
Not
IPC3602 1920 VA Yes (8) 5-15R (1) 20A 20A Yes C20 Inlet 1.7 x 19.0 x 19.5
Included
IPC3601-F3-3316 5760 VA Yes (8) C13 (2) 15A No Yes L6-30P 10 1.7 x 19.0 x 19.5
Rear view
Front view
IPC3601
Rear view
IPC36XX
IPC3602
• Serial interface provides a text menu control interface with any
(12) Indicator lights
terminal emulation software
• Main power system on
• FTP utility allows firmware upgrades
• Power on to outlets 1-8
• Two data and ethernet link
Software security
• User name/password security
EMI/RFI filtering
• Settings allow the administrator to disable unused interfaces
• Common mode - line to ground
• Differential mode -line to line
Software features
• Filtered inlet isolates noise before entering the system
• Administrator and multiple users can be configured
• Refer to chart 4 on page 40
• User level access can be limited to specific outlets
• Unit and outlet names can be configured
Spike/surge suppression
• Outlet groups can be created to perform an action on multiple
• Line to neutral (or line)
outlets
• Refer to chart 1 on page 40
• Outlet control includes individual, group and all outlet global
Serial/ethernet
control
• Outlet actions include on or off and reboot
• Serial RS232 via RJ22 connector on the rear. 6’ RJ22 to DB9
• Global sequence allows all the outlets to be turned on or off in
cable included
a preset sequence up to 999 seconds
• Serial baud rate is 9600 default or 38,400 maximum
• Outlet reboot automatically turns an outlet off and back on with
• Ethernet (10/100) network via RJ45 connector on the rear. 6’
one command at a preset time up to 999 seconds
network cable included
• Email notification allows up to two email addresses to receive
• Network setup allows DHCP or any static public/private IP
notifications of alerts or events
address
Software interfaces
Auto-event scheduling
• Web interface provides a graphic control interface through a
Administrator can configure on or off events for outlets or groups.
Web browser
The event occurs at the preset time daily or weekly.
• Telnet interface provides a text menu control interface with any
terminal emulation software
• SNMP allows read/write capability with trapping
• Email notification system provides email alerts or logs showing
user activity
28 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
Intelligent Power Control IPC3400 series
Power
EMI/RFI Surge Serial Control Ethernet Dimensions
Catalog Number Full Load Receptacles Cord (ft) Input
Filter Suppression (RS232) Control (H x W x D, in)
Plug
IPC3400-A1 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes No 3.4 x 9.0 x 5.8
IPC3400-A1-NET 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes Yes 3.4 x 9.0 x 5.8
IPC3400-AB 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes No 3.4 x 9.0 x 5.8
IPC3400-AB-NET 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes Yes 3.4 x 9.0 x 5.8
Front view Rear view
IPC3400-A1-NET
(6) Indicator lights Password protection
• (1) Main power For added security, a password feature is included which allows
• (1) Data light you to assign a three alphanumeric character password
• (4) Power on to outlets 1-4
Addressing
Communications
The IPC comes with a default address but you can also create your
• RS232, Serial: 9600 baud only own with any four alphanumeric characters
• Optional ethernet control via RJ45 connector (add -NET
Watch-dog/auto-reboot
to part number)
• The IPC monitors the control connection and automatically
• Data terminal emulation software is required to communicate
reboot itself if the connection locks up. The auto-reboot is
with the IPC internal command codes such a telnet or
activated by the time-out period running down to zero. When
hyperterminal
this occurs the IPC shuts down all outlets for four seconds and
EMI/RFI filtering
restart in the default or user defined sequence
• Common mode - line to ground • Set the time out period to any number 0-9 where each digit
• Differential mode - line to line represents 30 seconds, i.e. 3 = 120 seconds (user defined)
• Refer to chart 2 on page 40
Commands available
Spike/surge suppression
• All outlets on/off
• L-N, L-G, N-G • Individual outlet on/off
• Refer to chart 1 on page 40 • Set up and sequence on/off all outlets
• Create password and unit address
Outlet status
• Name outlets with eight character name
Query the IPC for Outlet and Watchdog status, i.e. outlets are (on
• Set up, enable or disable Watchdog
or off)
• Display outlet and Watchdog timer status
Multiple time delay (MTD)
• Turn outlets on or off at one time
• Sequence power up and power down to outlets 1 - 4 with a
four-second time delay (factory set)
• Set power on sequence to any combination of outlets
• Set the MTD timing from one second to 999 seconds,
i.e. 009 = 9 seconds
eaton.com/epdu 1.800.356.5794
29North American TPC115-10 series single-phase systems
120V~ OR 240V~, 15A, 20A and 30A, 50/60 Hz
EMI/RFI Multi-Stage Surge Dimensions
Catalog Number Full Load Receptacles Circuit Breaker Cord (ft) Input Plug
Filter Suppression (H x W x D, in)
TPC115-10-A 1440 VA (10) 5-15R (1) 15A 20A 270V/150V 9 5-15P 1.7 x 19.0 x 8.0
TPC115-10-A2 1920 VA (10) 5-20R (1) 20A 20A 270V/150V 9 5-20P 1.7 x 19.0 x 8.0
TPC115-10-B 2880 VA (10) 6-15R (2) 15A 20A 320V/270V 9 N/A 1.7 x 19.0 x 8.0
TPC115-10-C
2880 VA (10) 5-15R (2) 15A 30A 270V/150V 15 L5-30P 1.7 x 19.0 x 8.0
TPC115-10-D 2880 VA (10) 5-20R (2) 15A 30A 270V/150V 15 L5-30P 1.7 x 19.0 x 8.0
TPC115-10-F 5760 VA (10) 6-15R (2) 15A 30A 320V/270V 15 L6-30P 1.7 x 19.0 x 8.0
Front view Rear view
TPC115-10-D
(10) NEMA outlets Multiple time delay (MTD)
• Two unswitched on front and eight switched on rear panel. • Activated locally or remotely, SW-I outlets power up
Unswitched outlets are tied to the SW-II outlet section immediately, followed four seconds later by SW-II outlets which
is followed four seconds later by the sequenced remote I/O
(3) Indicator lights
port.
• Main breaker power on and power to the unswitched outlets
• Add /MTD after part number, i.e. TPC115-10-A/MTD
• Power on to the SW-I outlets
Remote I/O ports
• Power on to the SW-II outlets
• Three front/two rear (see page 39)
Spike/surge suppression
• Remote on/off and EPO control, EPO overrides remote and local
• L-N, L-G, N-G
control
• Refer to Chart 1 on page 40
• Sequence power up additional equipment down line (third
connector on front panel)
EMI/RFI filtering
• Latching remote feature - (N/C) EPO, momentary start – Add -LT
• Common mode line to ground
to the part number when the MTD feature is not being used –
• Differential mode line to line
Add /LT to the part number when the MTD feature is used
• Refer to page 40
Local/off/remote switching
• Local: Power on or off to the switched outlets
• Off: When breaker is on but this switch is in the off mode, you
have power to the unswitched outlets only
• Remote: Power on or off to the switched outlets via a remote
device
• Latching remote, on LT systems, has the selection switch wired
for remote/off/remote - There is no local control
30 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
International TPC2365 series single-phase systems
110-125V/200-240V~,16A, Single Phase, 50/60 Hz
Circuit Multiple EMI/RFI Surge Remote Dimensions
Catalog Number Receptacles Cord (ft) Input Plug
Breaker Time Delay Filter Suppression Control (H x W x D, in)
Not
TPC2365 (1) 20A No Yes (20A) 320V (12) C13 Standard C20 Inlet 1.7 x 19.0 x 8.0
Included
Not
TPC2365/MTD (1) 20A Yes Yes (20A) 320V (12) C13 Standard C20 Inlet 1.7 x 19.0 x 8.0
Included
Not
TPC2365-LT (1) 20A No Yes (20A) 320V (12) C13 Latching C20 Inlet 1.7 x 19.0 x 8.0
Included
Not
TPC2365/LT (1) 20A Yes Yes (20A) 320V (12) C13 Latching C20 Inlet 1.7 x 19.0 x 8.0
Included
TPC2365-2980 (1) 10A Yes Yes (30A) 320V (12) C13 Latching 15 Bare Wire 1.7 x 19.0 x 8.0
TPC2365-3732 (1) 10A Yes Yes (30A) 320V (12) C13 Latching 15 L6-30P 1.7 x 19.0 x 8.0
Front view Rear view
TPC2365
EMI/RFI filter Remote interface
• Differential mode - line to line • Remote on/off and EPO control - EPO overrides remote and
• Common mode - line to ground local control
• Refer to Chart 4 on page 40 • Sequence power up additional equipment down line (standard
on all units
Spike/surge suppression
• Latching remote LT models only - normally closed EPO,
• Line to line
momentary start
• Refer to Chart 1 on page 40
Optional multiple time delay (MTD)
Remote selection switch
• Activated locally or remotely, section 1 powers up, followed
• Local: Power on or off to the switched outlets
four seconds later by section 2 which is followed four seconds
• Off: When breaker is on but this switch is in the off mode, you
later section 3 then four seconds later the sequenced remote
do not have power to the outlets
activates the next system in line
• Remote: Power on or off to the switched outlets via a remote
(5) Indicator lights
device
• Latching remote on LT models only, the selection switch is wired • Power to section 1, 2 and 3
for remote/off/remote - There is no local control • 115 Vac or 230 Vac input selected
• Refer to page 39 for remote configurations
Auto-voltage selection
The AVS system automatically senses the input voltage and
adjusts the internal components to use that voltage for the output
eaton.com/epdu 1.800.356.5794
31North American TPC4100 series three-phase systems
120/208V~ Three-Phase WYE, 20A and 30A, 50/60 Hz
Circuit EMI/RFI Surge Dimensions
Catalog Number Receptacles Remote Cord (ft) Input Plug
Breaker Filter Suppression (H x W x D, in)
TPC4100-A2 (12) 5-20R (3) 20A No 30A 150V 9 L21-20P 1.7 x 19.0 x 9.5
TPC4100-B (12) 6-15R (3) 15A No 30A 270V 9 L21-30P 1.7 x 19.0 x 9.5
TPC4100-AB (6) 5-15R, (6) 6-15R (3) 15A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5
TPC4100-C (12) 5-15R (3) 15A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5
TPC4100-D (12) 5-20R (3) 20A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5
Yes -
TPC3474 (6) 5-20R, (6) 6-20R (3) 20A No 150V 9 L21-30P 1.7 x 19.0 x 9.5
Latching
Front view Rear view
TPC4100-AB
EMI/RFI filtering
• Common mode - line to ground
• Differential mode - line to line
• Refer to Chart 8 on page 40
Spike/surge suppression
• Line to line
• Refer to Chart 1 on page 40
(3) Indicator lights
Provided for each phase power on via breaker
32 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
North American PC2641 series three-phase systems
120/208V~ Three-Phase WYE, 30A, 50/60 Hz
Main
Secondary Unswitched
Full Circuit EMI/ Multiple
Catalog Circuit Duplex Surge Cord Remote Input Dimensions
Load Per Receptacles Breaker RFI Time
Number Breakers Circuit Suppression (ft) Control Plug (H x W x D, in)
Phase (on/off Filter Delay
Per Phase Breaker
switch)
Standard
PC2641-D
2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V 15 No L21-30P 3.4 x 19.0 x 14.5
Remote
PC2641- Latching
2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V 15 No L21-30P 3.4 x 19.0 x 14.5
D-LT Remote
PC2641-D/ Standard
2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V 15 Yes L21-30P 3.4 x 19.0 x 14.5
MTD Remote
Latching
PC2641-D/LT 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V 15 Yes L21-30P 3.4 x 19.0 x 14.5
Remote
Front view Rear view
PC2641-D
(14) NEMA outlets Multiple time delay (MTD)
• Two unswitched outlets • PH-X powers up immediately, followed four seconds later by
• 12 switched outlets, four per phase PH-Y, which is followed four seconds later PH-Z, then four
seconds later the sequenced remote activates the next system
(4) Indicator lights
in line
• Main breaker power on to system and unswitched duplex
• PC2641-D/MTD and PC2641-D/LT only models
• Power on to PH-X, -Y, -Z outlets
(4) Remote I/O ports
Spike/surge suppression
• Remote on/off and EPO control, EPO overrides remote and local
• 320V MOV L-N
control
• Refer to Chart 1 on page 40
• Sequence power up additional equipment down line (standard
on all units)
EMI/RFI filtering
• Latching remote - normally closed EPO, momentary start. Units
• Common mode - line to ground
with LT in part number, i.e. PC2641-D-LT or /LT
• Differential mode - line to line
• Refer to Chart 9 on page 40
Local/off/remote switching
• Local: Power on or off to the switched outlets
• Off: When breaker is on but this switch is in the off mode, you
will have power to the unswitched outlets only
• Remote: Power on or off to the switched outlets via a remote
device
• When using the latching remote, the selection switch is wired
for remote/off/remote. There is no local control.
This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39).
eaton.com/epdu 1.800.356.5794
33North American PC975 series three-phase systems
120/208V~ Three-Phase WYE, 30A, 50/60 Hz
Main Circuit Secondary Unswitched
Full Load Breaker Circuit Duplex EMI/RFI Surge Input Dimensions
Catalog Number Receptacles Cord (ft)
Per Phase (on/off Breakers Circuit Filter Suppression Plug (H x W x D, in)
switch) Per Phase Breaker
(3) 2-Pole 20A thermal (8) 5-20R and
PC975, PC975-LT
2880 VA (4) 30A 30A 270V 15 L21-30P 3.4 x 19.0 x 14.5
20/20 reset (3) L6-20R
PC975-1969, 20A thermal (8) 5-20R and
2880 VA (4) 30A N/A 30A 270V 15 L21-30P 3.4 x 19.0 x 14.5
PC975-1969/LT reset (3) L21-30R
PC975-2109, (3) 1-Pole 15A thermal (8) 5-15R and
2880 VA (4) 30A 30A 270V 15 L21-30P 3.4 x 19.0 x 14.5
PC975-2109-LT 20 reset (3) L5-30R
Front view Rear view
PC975
EMI/RFI filtering Multiple time delay (MTD)
• Common mode - line to ground • Activated locally or remotely, PH-X powers up, followed four
• Differential mode - line to line seconds later by PH-Y, which is followed four seconds later PH-
• Refer to Chart 9 on page 40 Z, then four seconds later the sequenced remote activates the
next system in line
Spike/surge suppression
(4 N/O) Remote I/O ports
• 270V MOV L-N
• Refer to Chart 1 on page 40 • Remote on/off and EPO control, EPO overrides remote and local
control
(4) Indicator lights
• Sequence power up additional equipment down line (standard
• Main breaker power on
on all units)
• Power on to PH-X, Y and Z
• Latching remote - (N/C) EPO, momentary start. LT systems
Local/off/remote switching
• Local: Power on or off to the switched outlets
• Off: When breaker is on but this switch is in the off mode, you
have power to the unswitched outlets only
• Remote: Power on or off to the switched outlets via a remote
device
• When using the latching remote option, the selection switch is
wired for remote/off/remote. There is no local control
This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39).
34 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
International PC302-I/MTD three-phase systems
120/208V~ or 230/400V~ Three-Phase WYE, 20A, 50/60Hz
Full load Main Circuit EMI/RFI Filter Per Surge Dimensions
Catalog Number Receptacles Input
Per Phase Breaker Phase Suppression (H x W x D, in)
1920 VA or Terminal
PC302-I/MTD
(1) 20A (14) C13 20A 270V 3.4 x 19.0 x 14.5
3680 VA Block
1920 VA or Terminal
PC302-I/LT (1) 20A (14) C13 20A 270V 3.4 x 19.0 x 14.5
3680 VA Block
Front view Rear view
PC302-I/MTD
EMI/RFI filter Remote control
• Remote on/off and EPO control, EPO overrides remote and local
• Differential mode
control
• Common mode
• Sequence power up additional equipment down line
• Refer to Chart 2 on page 40
• Latching remote - (N/C) EPO, momentary start on PC302-LT only
Spike/surge suppression
Multiple time delay (MTD)
• Line to line
• Activated locally or remotely, PH-X powers up, followed four
• Refer to Chart 1 on page 40
seconds later by PH-Y, which is followed four seconds later
Voltage selection switch
PH-Z, then four seconds later the sequenced remote activates
• Select 120/208V~ or 230/400V~ input
the next system in line
• 120/208V~ input with 120V~ output
(6) Indicator lights
• 230/400V~ input with 230V~ output
• Main power on
Local/off/remote switching
• Power to phase X, Y and Z
• Local: on/off to switched outlets
• 120/208V~ input selected
• Off: When breaker is on but this switch is in the off mode, you
• 230/400V~ input selected
will have power to the unswitched outlets only
See pages 38-39 for optional control panels.
• Remote: on/off to switched outlets via a remote control device
• Latching remote, the selection switch is wired for remote/off/
remote. There is no local control on the PC302-I/LT
Required Cable Assembly Options: CBL100: 20A with 12/5 cable 9’ long terminated with a NEMA
L21-20P for use in North America at 120/208V~
CBL102: 20A with 5x2.5mm Harmonized cable 9’ long.
A plug is not provided so that you can provide the
country specific plug for use in Europe at 230/400V~
eaton.com/epdu 1.800.356.5794
35International PC2672 series three-phase systems
120/208V~ OR 230V/400V~, Three-Phase WYE, 30A, 50/60 Hz
Secondary Listed Secondary Listed
Full Load Circuit EMI/RFI Dimensions
Catalog Number Breakers, (1) Each Breakers, (1) Each For Receptacles Cord (ft)
Per Phase Breaker Filter (H x W x D, in)
For The C19 Outlets A Pair of C13 Outlets
2880 VA
(12) C13
at 120/208V or
PC2672 (3) 30A (4) 16A (6) 10A (4) C19 30A 5 5.2 x 19.0 x 16.5
5520 VA
(1) IEC309 32A
at 230/400V
Cable Assembly Options:
CBL113: 10/5 cable 9’ long terminated with a NEMA L21-30P at one end and a mating IEC309 connector at the other end.
For use in North America at 120/208V~
CBL114: 5x4.0 mm harmonized cable 9’ long with an IEC309 connector at both ends. For use in Europe at 230/400V~
Voltage Selectable
Front view Rear view
EMI/RFI filtering (4) Remote I/O ports
• Common mode - line to ground • Two front / Two rear: one on each side is sequence and the
• Differential mode - line to line other is for remote on/off and EPO control. The PC2672 is
• Refer to Chart 9 on page 40 controlled remotely only
• Latching remote - (N/C) EPO between pins 2 & 3, momentary
(3) Indicator lights
start between pins 1 & 3
• Power on to PH-X, -Y, -Z
This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39).
36 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
Non-rackmount power distribution units
UPS extension systems
Circuit Input Output EMI/RFI Surge Dimensions
Catalog Number Receptacles Cord (ft) Input Plug
Breaker Voltage Voltage Filtering Suppression (H x W x D, in)
1
LPC120P 6 L5-30P 3.0 x 7.8 x 10.0
(4) 15A 120V~ / 30A 20V~ / 30A N/A N/A (8) 5-15R
LPC208-1P N/A 240V~ / 30A 240V~ / 30A N/A N/A (4) L6-30R 6 L6-30P 3.0 x 7.8 x 10.0
(3) L6-20R,
LPC208-2P (3) 20A 240V~ / 30A 240V / 30A N/A N/A 6 L6-30P 3.0 x 7.8 x 10.0
(1) L6-30R
120-240V~
1
LPC1224-1P (6) 15A 120V N/A N/A (12) 5-15R 6 L14-30P 3.0 x 7.8 x 10.0
/ 30A
100-240V~ 100-240V~
LPC2872-1 N/A N/A N/A (6) C13 C20 Inlet N/A 3.0 x 7.8 x 10.0
/ 20A / 20A
1. 15A thermal reset breaker for each duplex
2. Each L6-30R with a 2-pole 20A breaker and kick guard and (1) L6-30R unswitched outlet
LPC120P LPC1224-1P LPC208-1P LPC208-2P
LPC2872-1
eaton.com/epdu 1.800.356.5794
37Remote control panels
Allows immediate and complete ‘power off’ control from one button.
Dimensions
Model Remote Type Color Receptacle Switch/EPO
(H x W x D, in)
RCP100-GRY Standard 1.73 x 19.0 x 2.0 Gray None 2-position/normally open
RCP100-BLK Standard 1.73 x 19.0 x 2.0 Black None 2-position/normally open
1
RCP100-GRY-LT Latching 1.73 x 19.0 x 2.0 Gray None 3-position/normally closed
1
RCP100-BLK-LT Latching 1.73 x 19.0 x 2.0 Black None 3-position/normally closed
1. Latching (LT) control panels must be ordered with power distribution units that are latching, identified by LT at the end of the part number.
RCP100-BLK-LT RCP100-GRY
Rack mounted On/off switch
• Flush mounted, 18 GA. Steel • RCP100-GRY: 2-position ON/OFF switch
• Painted FED-STD 595 #26559 light texture gray • RCP100-GRY-LT: 3-position spring return dial switch for OFF
• Optional: Painted FED-STD 595 #26038 black (turns unit off and holds off), ON (puts unit in a standby mode),
• Remote cable is 15’ long START is a momentary action and powers up the unit
Emergency Power Off (EPO)
• RCP100-GRY: Locking (N/O) EPO button for PDUs with the
standard 3-pin remote I/O port. Turn to reset.
• RCP100-GRY-LT: Locking (N/C) EPO button for PDUs with the
latching (LT) option. Turn to reset.
• Per European requirements, there is a yellow square behind the
EPO button
38 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsIndustrial ePDUs
Sample remote circuits
Standard remote control interface
REMOTE START REQUIRES (2) CONDITIONS: SEQUENCED REMOTE:
1. The on/off/remote switch must be in the remote position. Connect pins 1, 2 & 3 of the sequence port to pins 1, 2 & 3 on
2. A maintained closure between pins 1 & 3 turns the any remote port of the slave unit. (Do not connect to another
unit on. sequence port!)
The sequence port of the master unit activates four seconds
REMOTE POWER OFF REQUIRES (1) CONDITION:
after the final set of outlets turn on. Additional units may be daisy
Opening the maintained connection between pins 1 & 3 turns
chained in this fashion.
off the switched outlets.
CAUTION!
THIS TYPE OF REMOTE IS NOT TO BE SUBSTITUTED
REMOTE EPO REQUIRES (1) CONDITION:
FOR A SAFETY INTERLOCK!
A maintained contact between pins 2 & 3 turns off the
switched outlets regardless of the position of the on/off/
EPO is normally open, so removing the EPO connection
remote switch.
will not shut down the power to the unit.
Latching remote LT control interface
REMOTE START REQUIRES (2) CONDITIONS: SEQUENCE REMOTE:
1. A maintained contact between pins 2 & 3. Connect pins 1 & 2 of the sequence port to any remote port on
2. A momentary contact between pins 1 & 3. another -LT unit. The sequence port activates four seconds
after the final set of outlets turn on. (Do not connect to another
sequence port!)
REMOTE POWER OFF OR EPO REQUIRES (1) CONDITION:
Opening the maintained connection between pins 2 & 3.
NOTE: LT units are designed for remote operation only. Even when
Additional EPO or stop buttons can be connected in series
the REMOTE/OFF/LOCAL switch is set to LOCAL, the unit still
between pins 2 & 3.
requires a power request from the remote ports to turn the
This turns off the switched outlets regardless of the remote
unit on.
switch position.
REMOTE OPERATION: Most Eaton units have more than one remote connector. Unless labeled as SEQUENCE they are wired in parallel. Connection
to only one remote connector is required. It is recommended that an Eaton control panel be ordered for use with your PDU. Connectors are provided
for those who wish to wire their own switches or control panels. We recommend using 14 AWG wire and not exceeding 50 feet for any remote cable.
Mating control panels can be seen on our website at eaton.com/epdu.
If additional remote connectors are needed: The female AMP connectors used in our Power Controllers are: three pin - part number 1-480304-0 and
four pin part number 1-480425-0, and are used with AMP Socket Terminals, part number 60619-1. The mating male AMP connector is: three pin -
part number 1-480305-0, and four pin - part number 1-480426-0 and are used with AMP male contacts part number 60620-1.
eaton.com/epdu 1.800.356.5794
39Industrial ePDUs environmental, surge suppression and EMI/RFI filter performance
Chart 1: Chart 5: 025-3021
EMI/RFI Filtering Common Mode Insertion Loss
TVSS (Transient Voltage Surge Suppression)
MOV Specifications
Mhz. .15 .50 1.0 5.0 10.0 30.0
Continuous AC Voltage 150 Vac 270 Vac 320 Vac
dB. 6 19 28 42 45 50
Continuous DC Voltage 200 Vdc 360 Vdc 420 Vdc
Differential Insertion Loss
Max. DC Leakage 200 µA 200 µA 200 µA
Mhz. .15 .50 1.0 5.0 10.0 30.0
Low Varistor Voltage Limit 212 Vdc 389 Vdc 462 Vdc
dB. 2 40 60 65 57 55
High Varistor Voltage Limit 243 Vdc 453 Vdc 540 Vdc
Nominal Varistor Voltage 236 Vdc 424 Vdc 503 Vdc
Current For Varistor Voltage 1 mA 1 mA 1 mA
Chart 6: 025-2833
Max. Clamp Voltage 8x20 µs 360V 680V 810V
EMI/RFI Filtering Common Mode Insertion Loss
Max. Clamp Voltage Test Current 100A 100A 100A
Mhz. .1 .5 1.0 5.0 10.0 20.0 50.0
Peak Current Rating (1 Pulse) 12000A 10000A 10000A
dB. 18 40 48 62 80 70 60
Peak Current Rating (2 Pulse) 9000A 6500A 6500A
Energy Rating (10x1000 µs) 170J 325J 385J Differential Insertion Loss
Energy Rating (8x20 µs) 170J 325J 385J Mhz. .1 .5 1.0 5.0 10.0 20.0
dB. 21 33 41 50 50 50
Capacitance 1700 pF 970 pF 820 pF
Impulse Response Time 50 ns 50 ns 50 ns
Chart 2: 001-3000 Chart 7: 025-4000
EMI/RFI Filtering Common Mode Insertion Loss
EMI/RFI Filtering Common Mode Insertion Loss
Mhz. .2 1.0 2.0 10.0 Mhz. .05 .20 1.0 5.0 20.0 100.0
dB. 15 25 45 50 dB. 0 35 71 75 66 48
Differential Insertion Loss Differential Insertion Loss
Mhz. .2 1.0 2.0 10.0 Mhz. .05 .20 1.0 2.0 5.0 10.0
dB. 10 22 32 50 dB. 20 30 72 63 58 51
Chart 3: 010-0317 Chart 8: 025-3031
EMI/RFI Filtering Common Mode Insertion Loss EMI/RFI Filtering Common Mode Insertion Loss
Mhz. .01 1 10 20 50 100 Mhz. .05 .15 .50 1.5 5.0 20.0
dB. 8 29 40 50 68 40 dB. 4 18 38 44 50 50
Differential Insertion Loss Differential Insertion Loss
Mhz. .01 1 10 20 50 100 Mhz. .05 .15 .50 1.5 5.0 20.0
dB. 8 23 45 58 32 28 dB. 12 20 40 60 50 50
Chart 4: 025-2023
EMI/RFI Filtering Common Mode Insertion Loss
Mhz. .15 .50 1.0 5.0 10.0 30.0
dB. 6 19 28 42 45 50
Differential Insertion Loss
Mhz. .15 .50 1.0 5.0 10.0 30.0
dB. 6 6 30 50 30 30
40 eaton corporation Enclosure Power Distribution Units
Industrial ePDUsRack Power Module
Rack Power Module
The Rack Power Module (RPM) delivers up to 36 kW (hardwire option required, BladeUPS connector limits to 12 kW) of power to loads
of various voltages, power cords and layouts. The 3U RPM can be deployed in the same rack with the UPS and IT equipment; there’s no
need for a dedicated infrastructure rack. The resulting architecture has fewer cables to manage, fewer distribution points to monitor and
greater flexibility for IT personnel to make changes without an electrician. This unit is typically deployed with the Eaton BladeUPS units.
Features:
• Provides plug-and-play primary distribution of power from a three-phase input source to
secondary power distribution devices
• Serves data center loads with various voltages, power cord configurations and layouts
• Distributes three-phase power to 12 poles, grouped into two sets of six poles, with choice of
output receptacle types
• Power Equalizer LED display gives quick visual indication of each circuit’s load, reducing
possibility of overloads and breakers tripped off line
• Load information available from the front of the rack, no need to check individual power strips
in the rear of the cabinet (hot isle)
• Branch circuit monitoring option allows easy load monitoring over the network
• Installs in only 3U of space in EIA 19” rack or enclosure (or wall mounted), all hardware included
• Enables customer installation and changes without the services of a licensed electrician
Front view Rear view
RPM part number guide
(Base 3U RPM distribution box)
Y 0 3
0 0 0 0 0 0
Input voltage
1 = 208V
2 = 400V
Metering choices
Input cords/connection
1 = Power Equalizer
0 = Hardwire
2 = Energy Management System, NO Card
1 = BladeUPS Connector 208V
3 = Energy Management System, with card
2 = IEC309-60 5 wire
3 = L21-30P
Output receptacle plate #1 & #2
4 = BladeUPS Connector 400V
1 = L21-20R 9 = L14-30R
Input cords length
2 = L21-30R A = C13 (208V)
0 = Hardwire
3 = L6-15R B = C19 (208V)
1 = 6 feet
4 = L6-20R
C = C13 (230V) International
2 = 10 feet
5 = L6-30R D = C19 (230V) International
3 = 15 feet
6 = 5-15R E = L15-20R
4 = 20 feet
7 = 5-20R F = L15-30R
8 = L14-20R
eaton.com/epdu 1.800.356.5794
41ePDU plugs and receptacles
Standard NEMA plugs
6-20 L21-20
5-15 L22-20
208V 120/208V
120V 277/480V
20A 20A,
15A 20A
1 phase 1 phase 3 phase wye 3 phase wye
straight blade straight blade
5-20 L6-20 L21-30 L22-30
120V 208V
120/208V 277/480V
20A 20A 30A
30A
1 phase 1 phase 3 phase wye
3 phase wye
straight blade twist lock
L5-20 L15-20
L6-30
120V 208V 208V
20A 30A, 20A
1 phase 1 phase 3 phase delta
The IEC advantage:
twist lock
The IEC320 and IEC309
L5-30 L14-30 L15-30
120V 120/240V 208V
connectors described below
30A 30A 30A
are the most commonly
1 phase 2 phase 3 phase delta
specified. The IEC connector
twist lock (split phase)
system is used throughout
the world. By utilizing an
Eaton ePDU with the IEC
connectors, you can attach
the correct cable assembly for
British, Australian, Continental
IEC320
European, North American and
many other cable/connector
configurations. This allows you
to purchase and inventory one
ePDU for shipment anywhere
C13 C14 C19 C20
in the world.
North American 15 amp 250 volts 20 amp 250 volts
Europe 10 amp 250 volts 16 amp 250 volts
IEC309
30A 60A 30A 60A 60A 60A
Y General ePDU
X environmental
specifications
G
• Operating temperature
332P6 360P6 532P6 460P9 560P9 563P6
is 0 to 50°C (32-122°F)
250V 250V 3ØY230/400V 3Ø250V 3ØY120/208V 3ØY230/400V
• Storage temperature
is -40 to 70°C (-40 to 158°F)
50A, 50A,
• Altitude maximum
2P3W 3P4W
10,000 ft.
250V 3Ø250V
• Relative humidity is 95%
Y Y
max non-condensing
X X
Z
G
G
HBLCS8365C
HBLCS8265C
42 eaton corporation Enclosure Power Distribution Units
Y
X
Z
G
ePDU plugs and receptaclesPower cables and accessories
Power cables and accessories
By turning to Eaton, you can enjoy one-stop shopping for a full range of power quality and power distribution needs, including power
cables. The Eaton cable portfolio includes nearly two dozen choices in three product categories including adapters, jumpers and splitters.
All Eaton power cables are tested and certified for use with Eaton products, such as ePDUs, rack power modules (RPMs) and UPSs—
proven to deliver the reliability and service life needed for the most rigorous data center applications.
Splitter cables Adapter cables
010-0032: 010-9334:
C14 to 5-15R 5-15P to C19
125V, 15A 125V, 15A straight blade
1 foot, 16 AWG/3-wire 8-foot, 14 AWG/3-wire
010-9335: 010-9336:
CBL139 Splitter Cable
5-20P to C19 6-15P to C19
L14-30R to (2) L6-30R (4 ft/2 ft)
125V, 20A straight blade 250V, 15A straight blade
8-foot, 12 AWG/3-wire 8-foot, 14 AWG/3-wire
010-9337: 010-9338:
6-20P to C19 L5-15P to C19
250V, 20A straight blade 125V, 15A twist-lock
CBL143 Splitter Cable
8-foot, 12 AWG/3-wire 8-foot, 14 AWG/3-wire
L14-30R to (2) L5-30R (4 ft/2 ft)
010-9339: 010-9340:
L5-20P to C19 L6-15P C19 to
125V, 20A twist-lock 250V, 15A twist-lock
8-foot, 12 AWG/3-wire 8-foot, 14 AWG/3-wire
Jumper Cables
010-9341:
CBL148 Splitter Cable
L6-20P to C19 010-0025: 8-foot
L14-20R to (2) L5-20R (4 ft/2 ft)
010-0027: 6-foot
250V, 20A twist-lock
010-0028: 4-foot
8-foot, 12 AWG/3-wire
010-0029: 2-foot
C14 to C13
010-9342:
010-9365
C20 Male to C19
C14 to C19, 8-foot
20A
CBL149 Splitter Cable
8-foot, 12 AWG/3-wire
L21-30R to (3) L5-30R (4 ft/2 ft/1 ft)
010-0034:
8-foot, 12 AWG/3-wire 010-9369-03
C20 to C13, 3-foot
C19 to bare wire
010-9369-06
(Pig Tail)
C20 to C13, 6-foot
CBL150 Splitter Cable
Outlet Caps
L21-20R to (3) L5-20R (4 ft/2 ft/1 ft)
035-0113: 035-0119:
C13 outlet cap C19 outlet cap
Additional accessories
Temperature & humidity sensors
Optional sensors SENSOR - T1H1-10
(1) Temperature and humidity
SENSOR - T1-10
sensor, 10’ cable
(1) Temperature sensor, 10’ cable
SENSOR - T2H1-10
SENSOR - T2-10
EMP001
(1) Temperature and humidity
(2) Temperature sensor,
Environmental Monitoring Probe
sensor, 10’ cable
10’ cable each
Advanced Monitored and
(1) Temperature sensor, 10’ cable
Managed ePDUs only
eaton.com/epdu 1.800.356.5794
43Space-saving mounting options
Installing your new ePDU is quick and easy. There are models that mount horizontally in minimal rack space (1U or 2U), or vertically
in rack side pockets or rear channels—or on a wall or floor, saving traditional U space for IT equipment.
The units come with all mounting hardware included, ready to install. There’s no need to purchase additional mounting hardware
or accessories. Some units use a button-mount system and can be mounted in keyhole-type openings in popular racks, with no
tools required.
Space-saving mounting
Horizontal mounting options
Rack Mounting Hole
Specification Table
HOLE SPECIFICATION TABLE
Mounting Brackets Front Flush Optional
Are Detachable With Zero-U Bracket A Y Z
1.75 .25 1.25
Several Mounting Part Number - 001-1928-1
3.5 .875 1.75
Options Shown
5.25 .875 3.5
Vertical mounting
Industry standard keyhole button mounting
Tool-less Mounting
Variable clip-foot mounting
SUB-HRDWARE-017 -
Standard mounting
included, brackets
come attached to units.
Attach clip foot Snap ePDU to
to rail clip foot
Mounting style for eAM and
eMA only
Benefits of vertical
mounts
Eaton ePDUs can be
Button mount Blind mount to Bracket mount
with clip feet rail with clip feet with clip feet mounted vertically, allowing
you to save valuable
Mounting style for vertical Basic models with part numbers that start with EPBZ.
space. You can mount
them vertically in rack side
pockets, rear channels – or
on a wall, which allows you
to save traditional U space
For a detailed mounting process, please refer to our
for IT equipment.
mounting video on eaton.com/epdu
44 eaton corporation Enclosure Power Distribution Units
Space-saving mounting optionsCable restraint and management
Cable restraints and management
KIT-CABLRES-01
Transverse mounting
• Prevent downtime and accidental disconnection
• Secure cables/plugs to PDU
• Cable ties provide highest level of retention
KIT-CABLRES-08
• Black adjustable bracket versions allow front or rear mounting
– KIT-CABLRES-01 - fits 9.5” deep units
Transverse mounting
– KIT-CABLRES-03 - fits 7” deep units
• Fixed bracket versions allow attachment to rear only
– KIT-CABLRES-08 - Black
Vertical Models Cable Tray Rackmount Models Cable Tray
IPC34XX Series KIT-CABLRES-01
V42 Series KIT-CABLRES-21
IPC36XX Series KIT-CABLRES-01
V70A1 Series KIT-CABLRES-24
T17 KIT-CABLRES-03
V70A2 Series KIT-CABLRES-24
T982 Series KIT-CABLRES-03
V70AB Series KIT-CABLRES-22
TPC115-10 Series KIT-CABLRES-08
V70Bx Series KIT-CABLRES-24
T9092 Series KIT-CABLRES-08
V70Cx Series KIT-CABLRES-24
TPC2104 Series KIT-CABLRES-08
V70F1 Series KIT-CABLRES-24
TPC2105 Series KIT-CABLRES-03
V70F2 Series KIT-CABLRES-24
TPC2234 Series KIT-CABLRES-08
V70F3 Series KIT-CABLRES-24
T2235-Ax Series (Black 7”) KIT-CABLRES-03
V70F4 Series KIT-CABLRES-24
T2235-Cx Series (Black 9.5”) KIT-CABLRES-01
V70G1 Series KIT-CABLRES-24
T2235-Fx Series (Black 9.5”) KIT-CABLRES-01
V70H1 Series KIT-CABLRES-24 TPC4100 Series KIT-CABLRES-01
V70J1 Series KIT-CABLRES-24
VPC1917-1 KIT-CABLRES-23
VPC1917-4,-5 KIT-CABLRES-23
VPC1917-6 KIT-CABLRES-24
VPC1917-7 KIT-CABLRES-23 You must purchase cables separately.
VPC2769-A2 KIT-CABLRES-24
VPC2769-B2 KIT-CABLRES-23
VPC2864 Series KIT-CABLRES-23
VPC3106 Series KIT-CABLRES-23
AM/MA Series KBLT01
eaton.com/epdu 1.800.356.5794
45Racks and airflow management
Once you’ve decided which Eaton ePDU is best for your application, it’s time to find the perfect rack to install them in. Eaton’s provides a
full line of racks and airflow management solutions, for you to store, cool, power, manage and secure your critical IT equipment.
To view our entire portfolio of solutions, please visit powerquality.eaton.com.
Eaton Paramount enclosure system
Our premier enclosure platform, Paramount not only supports
an industry leading 2,200 pounds of equipment in a fully welded
frame, but it is also designed to adapt to the ever-changing
requirements of the data center through a scalable and modular
approach. Speed of deployment is essential to any company when
considering time to market. Paramount’s modularity and building
block design ensures quick reconfigurations and minimizes
downtime, protecting your initial investment.
Eaton Vantage S2 enclosure system
The Vantage S2 enclosure platform was designed with change
in mind, which is why so many Fortune 500 companies have
standardized on it. Eaton’s forward-thinking design engineers
continue to develop scalable enclosure solutions to help
customers store their latest technology without having to change
enclosure platforms, allowing them to maximize their original
investment.
46 eaton corporation Enclosure Power Distribution Units
Racks and airflow managementRacks and airflow management
Active Airflow Manager
Eaton’s HCS pressure based system with active airflow, when
combined with best practices, improves performance metrics
considerably. Allocating the correct amount of airflow at known
intake locations is the key to reducing energy consumption
while increasing equipment performance. Best practices such
as blanking panels, proper perforated tile placement and the
reduction of bypass airflow must be employed to ensure desired
results.
HCS for third-party racks
Convert existing enclosures to the HCS to eliminate the
incremental capital expense associated with having to add more
CRAC units or other supplemental cooling.
Eaton Heat Containment System (HCS)
Eaton's HCS is a simple, scalable and low cost rack-based solution
to cool up to 25 kW or more per enclosure without the expense of
adding supplemental CRAC units to your data center. This patented
technology is available on Eaton’s Paramount and Vantage S2
enclosure systems and can also be field retrofitted to most
manufacturers' enclosures. The HCS contains and directs the heat
exhaust of your IT equipment through the chimney that is attached
to the top rear of the enclosure. The hot air is then ducted to your
existing CRAC units through a plenum ceiling or high air returns.
Photo courtesy of Humana
Visit powerquality.eaton.com to view Eaton’s entire portfolio
of racks, enclosures and airflow management solutions
eaton.com/epdu 1.800.356.5794
47UNITED STATES CANADA Colombia: 01 800 518 1490 Jamaica: 800 534 2102
8609 Six Forks Road Ontario: 416.798.0112 Costa Rica: 0 800 012 1716 Nicaragua: 001 800 220 1992
Raleigh, NC 27615 Toll free: 1.800.461.9166 Dominican Republic: 1 888 751 4862 Panama: 00 800 226 6524
Toll Free: 1.800.356.5794 Ecuador: from Andinatel: 1 999 170 Peru: 0 800 54 514
LATIN AMERICA (code after 800 is WSC 5649) Puerto Rico: 1 877 740 1707
Aruba: 001 866 898 8812 El Salvador: 800 6772 Trinidad & Tobago: 1 800 206 0981
Eaton.com/epdu Argentina (South Cone): +5411 4124 Mexico: + 52 (55) 9000-5252 or 01 800 Venezuela: 0 800 100 8474
4000 08 EATON (32866)
Bahamas: 1 800 389 0368 Miami: 1 866 248 2224
Brazil: +55 113616 8500 Guatemala: 1 800 624 0099
Eaton, Powerware, Power Xpert and ePDU
are trade names, trademarks, and/or service
marks of Eaton Corporation or its subsidiaries
and affiliates.
©2012 Eaton Corporation
All Rights Reserved
Printed in USA
EPDUCAT
March 2012