+90(212)320 36 50
7,4038
$6,2878
BMT-203F
  • BMT-203F
Marka: Bdc

Seri: BMT SERİSİ MANYETİK PNÖMATİK SİLİNDİR SENSÖRÜ

Model: BMT-203F

Model Birim Fiyat Birim Fiyat Adet Stok
BMT-203F  Reed Kontak, M8-3 Pin Konnektörlü150 mmM8-3 pinFiyat Sorunuz: 0212 320 36 50
  • Ürün Hakkında
  • Dokümanlar
  • Yazılımlar
BMS Serisinin Yeni Yüzü
2 ve 3 Telli DC Modeller
Plastik Kılıf
Ortam Isısı : -25...+85 °C
Besleme Gerilimi : 10-30V DC/AC
Bağlantı Şekli : Kablolu ve M8-3 Pin Konnektörlü
Koruma Sınıfı : IP67
Boyutlar : 29,3x5,2x5 mm


    --------------------Atex Serisi Katalog.pdf-----------------
    Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 1 ATEX SENSORS CATALOGUE BDC ELECTRONIC S.r.l.was formed in 1970. Being the first in Italy to produce proximity sensors, it has gained in its business a lot of experience, thanks to its abilities to develop products to fulfil the market requirements. The extremely flexible company organization is able to satisfy customer's needs, assuring a high quality and reliable production, appreciated all over the world. Research and development is continuously working in order to offer solution to all kinds of problems and to find new applications. All the products are engineered to perform even in the arduous and most difficult conditions. The use of a quality system, certified according to standard ISO 9001:2008, affords the best care and precision in the fulfillment of all the realization sta- ges: from the engineering to the production, through a manufacturing process with high levels of automa- tion together with rigorous testings on each product.Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 2Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 3 BDC ELECTRONIC has obtained the ATEX notification of the production quality system and the ATEX certification according to the directive 94/9/EC for equipment intended for use in potentially explosive atmosphere.Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 5 PROXIMITY SENSORS TOTAL QUALITY FOR TOTAL PRECISION INTERNAL SURFACE TEST MOUNTING LABORATORY TECHNOLOGY (SMT) All the BDC ELECTRONIC products are tested with the most sophisticated high technology equip- ment to ensure conformity with the relevant of all the standards. The production process is based on the use of high technology machinery which allows the highest control levels for the quality of the fini- shed product. All stages are built with the maximum accuracy to make the finished product attain the highest standards of functional reliability. Completely automated processes for every stage ensure the creation of a product made to satisfy any requirement. WINDING RESIN DISPENSING MACHINE MACHINECatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 1 CONTENTS ATEX SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 INDUCTIVE ATEX SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (DC…A) * Cable output - diameters 4 - 5 - 6,5 - 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-5 Cable output - diameters 12 - 18 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-6 Cable output - diameters 30 - 45 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-7 Cable output with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-8 Cable output with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9 Connector output M12 x1 - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-10 Connector output M12 x1 - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-11 Connector output M12 x1 with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-12 Connector output M12 x1 with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-13 For high temperatures (- 20°÷ + 110°C) - Cable output - diameters 6,5 - 8 mm . . . . . . . . . . . . . . . . . . . . . . . pageA-14 For high temperatures (- 20°÷ + 110°C) - Cable output - diameters 12-18-30-45 mm . . . . . . . . . . . . . . . . . . . pageA-15 AMPLIFIED IN d.c. - Atex Certified II 1GD for zone 0;20 (DCA…MA) Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-16 AMPLIFIED IN d.c. - Atex Certified II 2GD for zone 1;21 (DCA…MB) Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-17 AMPLIFIED IN d.c. - Atex Certified II 3GD for zone 2;22 • CENELEC STANDARD (DCA…3GD) Cable output - diameters 6,5 - 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-18 Cable output - diameter 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-19 Cable output - diameters 18 - 30 - 45 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-20 Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-21 • SHORT SERIES (DSA…3GD) Cable output - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-22 Connector output M12 x1 - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-23 • EXTENDED SENSING DISTANCE (DCE…3GD) Cable output - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-24 Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-25 • SHORT SERIES WITH EXTENDED SENSING DISTANCE (DSE…3GD) Cable output - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-26 Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-27 • EXTENDED TEMPERATURE RANGE (-20°÷+ 80°C) (DCA…KST3GD) Cable output with LED - diameters 6,5-8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-28 Cable output with LED - diameter 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-29 Cable output with LED - diameters 18-30-45 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-30 Connector output M12 x1 with LED - diameters 8-12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-31 • FOR HIGH TEMPERATURES (-20°÷+ 100°C) (DCA…KSTB3GD) Cable output with LED - diameters 6,5-8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-32 Cable output with LED - diameter 12 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-33 Cable output with LED - diameters 18-30-45 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-34 Connector output M12 x1 with LED - diameters 8-12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-35 (*) = to be used coupled with associated apparatus for Atex sensors (section E)Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 2 CONTENTS CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. + a.c. - Atex Certified II 3GD for zone 2;22 (AXM…3GD) Cable output - diameters 12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-36 ANALOGUE LINEAR OUTPUT - Atex Certified II 1GD for zone 0;20 ( ) (DCL…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-37 Connector output M12 x1 - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-38 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (DC…P/...A) * Cable output with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page A-39 Cable output with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page A-40 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (DC…/…A) * Type Z - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-41 Type T - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-42 Type X and Y - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-43 Type P - 5 Position head - Terminal block output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-44 Type 80 - Cable and connector output M12 x1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-45 Type R - Cable and connector output M12 x1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-46 AMPLIFIED IN d.c. - Atex Certified II 3GD for zone 2;22 (DCA…3GD) Type Z - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-47 Type T - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-48 Type X and Y - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-49 SLOT INDUCTIVE ATEX SENSORS NAMUR SERIES - Atex Certified II 1GD for zone 0;20 () (DF…/…A) * Cable output - Slot width 3,5 - 5 - 6 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-50 Cable output - Slot width 15 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-51 (*) = to be used coupled with associated apparatus for Atex sensors (section E)Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 3 CONTENTS ATEX CAPACITIVE SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 () (NKS…/…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-3 Connector output M12 x1 - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-4 CYLINDRICAL CAPACITIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 () (NKS…P/…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-5 ATEX MAGNETIC SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING WITH REED CONTACT - Atex Certified II 1GD for zone 0;20 Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . .(BMS…/…MA) . . . . . . . page C-3 Cable output - NAMUR output ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(BMSN…/…A) . . . . . . . page C-4 * RECTANGULAR MAGNETIC ATEX SENSORS WITH REED CONTACT - Atex Certified II 1GD for zone 0;20 ( ) * For pneumatic cylinders with T slot - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . .(BMS…/…A) . . . . . . . page C-5 For pneumatic cylinders with T slot - Cable output - NAMUR output . . . . . . . . . . . .(BMSN…/…A) . . . . . . . page C-6 Type Z and W - Cable output . . . . . . . . . . . . . . . . . . . . . . . . .(BMSZ…/…A and BMSW/…A) . . . . . . . page C-7 Type Z and W - Cable output - NAMUR output . . . . . . . . . . .(BMSNZ…/…A and BMSBW/…A) . . . . . . . page C-8 MAGNETS Magnets for sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-9 ATEX SPEED SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page D-1 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Atex Certified II 3GD for zone 2;22 3-wire in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (DSD…/…3GD) . . . . . . . . page D-3 3-wire in a.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (ASD…/…3GD) . . . . . . . page D-5 (*) = to be used coupled with associated apparatus for Atex sensors (section E)Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 4 CONTENTS AMPLIFIERS AND REPEATERS FOR ATEX SENSORS General informations - How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-1 FOR NAMUR INPUTS OR CONTACTS Supply voltage 24 Vdc (D103xx) Relay output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-3 Transistor output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-5 Supply voltage 115 ÷ 230 Vac (D113xx) Relay output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-7 FOR ANALOGIC INPUTS Input 4 ÷ 20 mA - Output 4 ÷ 20 mA for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(D1010) . . . . . . page E-9 CONNECTORS FOR ATEX SENSORS MALE CONNECTORS PREASSEMBLED WITH SENSORS General informations - How to compose the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page F-1 CONNECTORS MOULDED WITH CABLE How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page G-1 Female ATEX Connectors M12x1 Straight in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C10…) . . . . . . .page G-3 Right angled in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C8B…) . . . . . . .page G-4 Male ATEX Connectors M12x1 Straight in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C9…) . . . . . . .page G-5 Right angled in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C9B…) . . . . . . .page G-6 MOULDED CONNECTING CABLES FOR ATEX SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page H-1 Male M12x1 straight - Female M12x1 . . . . . . . . . . . . . . . . . . . . . . (C9/C10/… - C9/C8B/…) . . . . . . . page H-3 Male M12x1 right angled - Female M12x1 . . . . . . . . . . . . . . . . . (C9B/C10/… - C9B/C8B/…) . . . . . . . page H-4Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-1 GENERAL INFORMATIONS ATEX SENSORS This catalogue is complementary to the BDC General Catalogue. Please refer to General informations, installation and stora- ge instructions on section "General information" of the General Catalogue. ATEX installation instructions are available on website www.bdcelectronic.com. The ATEX sensors meet the requirements of 94/9/EC directive and are certified by IMQ for use in potentially explosive atmo- spheres. The applied harmonized standards are listed on the product pages. It's very important to choose the category of the device according to the classification of the potentially explosive area: GASES, VAPOURS OR MISTS Zone 0: continuous danger An area in which an explosive gases atmosphere is continuously present or present for long periods. Zone 1: potential danger An area in which an explosive gases atmosphere is likely to occur in normal operation. Zone 2: minimum danger An area in which an explosive gases atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. DUSTS Zone 20: continuous danger An area in which an explosive dust atmosphere of is continuously present or present for long periods. Zone 21: potential danger An area in which an explosive dust atmosphere is likely to occur in normal operation. Zone 22: minimum danger An area in which an explosive dust atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. BDC products include sensors for category 1GD, 2GD and 3GD. Sensors for category 1GD are suitable for application in zone 0-20, 1-21, and 2-22. They are of two types: - Amplified with protection by encapsulation "m", associated apparatus is not required. - NAMUR with protection by intrinsic safety "ia", require associated apparatus. The sensor with protection by intrinsic safety "ia" require associated apparatus certified. To find the appropriate associated apparatus contact our technical department. The final user must use the products according with the instruction manuals supplied. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-1 A-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-3 HOW TO INTERPRETE THE ORDERING REFERENCES INDUCTIVE ATEX SENSORS AXM = cylindrical amplified a.c. + d.c. 2-wire 10 ÷ 50 V DC = cylindrical NOT amplified d.c. NAMUR series DCA = cylindrical amplified d.c. DCE = cylindrical extended sensing distance d.c. series DCL = cylindrical analogue linear output DF = slot sensors NOT amplified d.c. NAMUR series DSA = cylindrical amplified d.c. SHORT series DSE = cylindrical amplified extended sensing distance d.c. SHORT series Diameter of cylindrical sensor or slot width for slot types. For other types, change the number with the following: 80 = diameter 80 mm P = rectangular plastic 5 positions head 40 x 40 x 112 R = rectangular plastic with adjustable sensing distance 100 x 111 x 30 T = rectangular plastic 25 x 40 x 12 X = rectangular plastic 25 x 50 x 10 Y = rectangular plastic 30 x 50 x 15 Z = rectangular plastic 16 x 28 x 10 P = plastic housing sensor 4 = flush mounting 5 = non flush mounting DC 18 P/ 4 6 0 9 KS A -5 PR 3 = with connector M12 x 1 6 = standard type cable output 7 = cable output with sheath support 8 = with gland A = body length 50 mm completely threaded H = male connector wired to the sensor (see page F-1) 0 = NO output (models with LED) or NC (models without LED) 1 = NC (normally closed output) 2 = NO + NC (complementary outputs) C = NC (output normally closed on pin 2 of connector) 0 = NAMUR series 2-wire 8 = NPN 9 = PNP L = smooth body K = protection against short circuit and overload S = LED output status T = high temperature version A = category 1G - 1D - NAMUR Series - Mode of protection “ia”: to be used with associated apparatus MA = category 1G - 1D - Amplified Series - Mode of protection “m” MB = category 2G - 2D - Amplified Series - Mode of protection “m” 3GD = category 3G - 3D - Amplified Series - Mode of protection “n” and “t” Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-3Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-5 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - diameters 4 - 5 - 6,5 - 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing A L5 L1 L2 d Housing B L5 L1 L2 d Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 ?d Technical data: with metal D (mm) 0 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc Sn (switching point) • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA Diameter M5 x 0,5 M8 x 1 without metal: ? 3 mA Size SW7 SW13 • Temperature range: - 20° ÷ + 60°C Nut Thickness mm 2,5 4 • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% Max tightening 2 10 torque Nm • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,14 mm in diameters 4 and 5 mm Materials: 2 0,35 mm in diameter 6,5 • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Marking: II 1D Ex iaD 20 T80°C • Housing: stainless steel II 1G Ex ia IIC T6 • Sensing face: plastic • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated appa- ratus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I brown + Rx blue --- mm mm mm mm mm mm mm KHz mm • A - 20 - - 20 3 4 5 0,8 DC4/4600LA • B - 20 - - 20 3 M5 x 0,5 5 0,8 DC5/4700A • A - 25 - - 25 4 6,5 5 1,5 DC6,5/4700LA • A 5 20 - - 25 4 6,5 3 2,5 DC6,5/5700LA • B - 25 - - 25 4 M8 x 1 5 1,5 DC8/4700A • B 5 20 - - 25 4 M8 x 1 3 2,5 DC8/5700A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-5 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-6 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES diameters 12 - 18 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B L5 L1 L2 d Housing F-1 L5 L1 L2 L4 d Typical curve I(mA) 4 without metal Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc 3 • Max ripple: 10% 2 1,75mA • Consumption at 8,2 V with Rx = 1000 ? ?I 1,55mA with metal: ? 1 mA 1 ?d without metal: ? 3 mA with metal D (mm) 0 • Temperature range: - 20° ÷ + 60°C Sn (switching point) • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 Diameter M12 x 1 M18 x 1 2 • Cable conductor cross section: 0,35 mm in diameter 12 mm Size SW24 SW17 2 0,75 mm in diameter 18 mm Nut Thickness mm 4 4 • Marking: II 1D Ex iaD 20 T80°C Max tightening II 1G Ex ia IIC T6 15 35 torque Nm • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 Materials: • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing: nickel plated brass • Sensing face: plastic Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I brown + Rx blue --- mm mm mm mm mm mm mm KHz mm B • - 30 - - 30 4 M12 x 1 5 2 DC12/4600A F -1 • - 30 - 20 50 4 M12 x 1 5 2 DC12/4700A B • 7 23 - - 30 4 M12 x 1 1 4 DC12/5600A F -1 • 7 23 - 20 50 4 M12 x 1 1 4 DC12/5700A B • - 30 - - 30 5 M18 x 1 1 5 DC18/4600A F -1 • - 30 - 20 50 5 M18 x 1 1 5 DC18/4700A B • 10 20 - - 30 5 M18 x 1 0,5 8 DC18/5600A F -1 • 10 20 - 20 50 5 M18 x 1 0,5 8 DC18/5700A A-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-7 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES diameters 30 - 45 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-9 L5 L1 L2 d Housing F-2 L5 L1 L2 L4 d Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA Technical data: 1 ?d • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc with metal D (mm) 0 • Max ripple: 10% Sn (switching point) • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA without metal: ? 3 mA Diameter M30 x 1,5 M45 x 1,5 • Temperature range: - 20° ÷ + 60°C Size SW36 SW55 Nut • Max thermal drift of sensing distance S : ± 10% r Thickness mm 5 5 • Repeat accuracy (R): 2% Max tightening • Degree of protection according EN60529: IP67 80 70 torque Nm 2 • Cable conductor cross section: 0,75 mm • Marking: II 1D Ex iaD 20 T80°C Materials: II 1G Ex ia IIC T6 • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Certified IMQ 08 ATEX 010 • Housing: nickel plated brass • Electromagnetic compatibility (EMC) according to EN60947-5-2 • Sensing face: plastic • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I brown + Rx blue --- mm mm mm mm mm mm mm KHz mm • B - 9 - 35 - - 35 5 M30 x 1,5 0,3 10 DC30/4600A • F - 2 - 35 - 20 55 5 M30 x 1,5 0,3 10 DC30/4700A • B - 9 15 20 - - 35 5 M30 x 1,5 0,2 15 DC30/5600A • F - 2 15 20 - 20 55 5 M30 x 1,5 0,2 15 DC30/5700A • B - 9 - 35 - - 35 5 M45 x 1,5 0,3 20 DC45/4700A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-7 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-8 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B L5 L1 L2 d LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V; O.R. • Housing: stainless steel General features: • Sensing face: plastic With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally trig- gered and monitored by LED. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Max ripple: 10% • Off-state current (I ): ? 1 mA r • Minimum operational current (I ): 2 mA m • Rated operational current (I ): 10 mA e • Voltage drop (U ) with load 10 mA: < 6,5 V d • Voltage drop (U ) with load 8 mA: < 5 V d • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Protected against any wrong connection • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC brown brown I I + + blue blue --- --- Rx Rx mm mm mm mm mm mm mm KHz mm • B - 30 - - 30 4 M8 x 1 3 1,5 DC8/4600SA DC8/4610SA • B 5 25 - - 30 4 M8 x 1 2 2,5 DC8/5600SA DC8/5610SA A-8 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-9 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-4 L5 L1 L2 d LED Housing B-5 L5 L1 L2 LED d General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally trig- gered and monitored by LED. Housing B-9 L5 Technical data: L1 L2 • Working voltage: 7,7 ÷ 9 Vdc • Max ripple: 10% • Off-state current (I ): ? 1 mA r LED • Minimum operational current (I ): 2 mA m d • Rated operational current (I ): 10 mA e • Voltage drop (U ) with load 10 mA: < 6,5 V d • Voltage drop (U ) with load 8 mA: < 5 V d • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% Diameter M12 x 1 M18 x 1 M30 x 1,5 • Switching hysteresis max (H): 10% Size SW17 SW24 SW36 • Degree of protection: IP67 Nut Thickness mm 4 4 5 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm in diameter 12 mm Max tightening 15 35 80 torque Nm 2 0,75 mm in diameters 18 and 30 mm • Marking: II 1D Ex iaD 20 T80°C Materials: II 1G Ex ia IIC T6 • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V; O.R. • Certified IMQ 08 ATEX 010 • Housing: nickel plated brass • Protected against short-circuit and overload • Sensing face: plastic • Protected against any wrong connection • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC brown brown I I + + blue blue --- --- Rx Rx mm mm mm mm mm mm mm KHz mm • B - 4 - 30 - - 30 4 M12 x 1 2 2 DC12/4600KSA DC12/4610KSA • B - 4 7 23 - - 30 4 M12 x 1 1 4 DC12/5600KSA DC12/5610KSA • B - 5 - 30 - - 30 5 M18 x 1 0,8 5 DC18/4600KSA DC18/4610KSA • B - 5 10 20 - - 30 5 M18 x 1 0,6 8 DC18/5600KSA DC18/5610KSA • B - 9 - 35 - - 35 5 M30 x 1,5 0,8 10 DC30/4600KSA DC30/4610KSA • B - 9 15 20 - - 35 5 M30 x 1,5 0,4 15 DC30/5600KSA DC30/5610KSA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-9 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-10 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12x1 Housing I L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 ?d with metal D (mm) 0 Sn (switching point) Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: • Housing: stainless steel • Sensing face: plastic Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA without metal: ? 3 mA • Temperature range: - 20° ÷ + 60°C : ± 10% • Max thermal drift of sensing distance S r • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I 1 brown + Rx 2 blue --- mm mm mm mm mm n° mm KHz mm • I - 26 13 8 47 8B - 10 M8 x 1 4 1,5 DC8/4300A • I 5 21 13 8 47 8B - 10 M8 x 1 3 2,5 DC8/5300A A-10 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-11 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12x1• Housing I-9 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 Housing I-1 L5 L1 L2 L3 L4 2 d 3 1 M12 x 1 4 Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA Technical data: 1 ?d • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc with metal D (mm) 0 • Max ripple: 10% Sn (switching point) • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA Diameter M12 x 1 M18 x 1 M30 x 1,5 without metal: ? 3 mA Size SW17 SW24 SW36 • Temperature range: - 20° ÷ + 60°C Nut Thickness mm 4 4 5 • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% Max tightening 15 35 80 torque Nm • Degree of protection according EN60529: IP67 • Marking: II 1D Ex iaD 20 T80°C Materials: II 1G Ex ia IIC T6 • Housing: nickel plated brass • Certified IMQ 08 ATEX 010 • Sensing face: plastic • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I 1 brown + Rx 2 blue --- mm mm mm mm mm n° mm KHz mm I - 9 • - 30 10 8 48 8B - 10 M12 x 1 2 2 DC12/4300A I - 9 • 7 23 10 8 48 8B - 10 M12 x 1 1 4 DC12/5300A I - 1 • - 27 15 8 48 8B - 10 M18 x 1 0,8 5 DC18/4300A I - 1 • 10 17 15 8 48 8B - 10 M18 x 1 0,6 8 DC18/5300A I - 1 • - 25 17 8 50 8B - 10 M30 x 1,5 0,8 10 DC30/4300A I - 1 • 15 25 17 8 65 8B - 10 M30 x 1,5 0,4 15 DC30/5300A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-11 Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-12 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12 x 1 Housing I L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: • Housing: stainless steel • Sensing face: plastic General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally trig- gered and monitored by LED. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Max ripple: 10% • Off-state current (I ): ? 1 mA r • Minimum operational current (I ): 2 mA m • Rated operational current (I ): 10 mA e • Voltage drop (U ) with load 10 mA: < 6,5 V d • Voltage drop (U ) with load 8 mA: < 5 V d • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Protected against any wrong connection • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC 1 brown 1 brown I I + + 4 blue 2 blue Rx --- Rx --- mm mm mm mm mm n° mm KHz mm • I - 26 13 8 47 8B - 10 M8 x 1 3 1,5 DC8/4300SA DC8/4310SA • I 5 21 13 8 47 8B - 10 M8 x 1 2 2,5 DC8/5300SA DC8/5310SA A-12 A-12 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-13 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12 x 1 • Housing I-9 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L5 L1 L2 L3 L4 2 General features: d M12 x 1 3 1 With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- 4 sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load 4 x LED can be applied on both terminals (function PNP or NPN). The output is internally trig- gered and monitored by LED. Diameter M12 x 1 M18 x 1 M30 x 1,5 Technical data: Size • Working voltage: 7,7 ÷ 9 Vdc SW17 SW24 SW36 Nut • Max ripple: 10% Thickness mm 4 4 5 • Off-state current (I ): ? 1 mA r Max tightening 15 35 80 torque Nm • Minimum operational current (I ): 2 mA m • Rated operational current (I ): 10 mA e Materials: • Voltage drop (U ) with load 10 mA: < 6,5 V d • Housing: nickel plated brass • Voltage drop (U ) with load 8 mA: < 5 V d • Sensing face: plastic • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Protected against short-circuit and overload • Protected against any wrong connection • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC 1 brown 1 brown I I + + 4 blue 2 blue --- --- Rx Rx mm mm mm mm mm n° mm KHz mm • I - 9 - 30 10 8 48 8B - 10 M12 x 1 2 2 DC12/4300KSA DC12/4310KSA • I - 9 7 23 10 8 48 8B - 10 M12 x 1 1 4 DC12/5300KSA DC12/5310KSA • I - 1 - 27 15 8 49 8B - 10 M18 x 1 0,8 5 DC18/4300KSA DC18/4310KSA • I - 1 10 17 15 8 49 8B - 10 M18 x 1 0,6 8 DC18/5300KSA DC18/5310KSA • I - 1 - 25 17 8 50 8B - 10 M30 x 1,5 0,8 10 DC30/4300KSA DC30/4310KSA • I - 1 15 25 17 8 65 8B - 10 M30 x 1,5 0,4 15 DC30/5300KSA DC30/5310KSA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-13 Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-14 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES For high temperatures Ø 6,5 - 8 mm (-20° ÷ + 110° C) • ATEX certified II 1GD for zone 0;20 • Cable output Housing A L5 L1 L2 d Housing B L5 L1 L2 d Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 ?d with metal D (mm) 0 Sn (switching point) Technical data: Diameter M8 x 1 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc Size SW13 • Max ripple: 10% Nut Thickness mm 4 • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA Max tightening 10 torque Nm without metal: ? 3 mA • Temperature range: - 20° ÷ + 110°C Materials: • Max thermal drift of sensing distance S : ± 10% r • Cable: 2 m thermoplastic 140°C; 300 V; O.R. • Repeat accuracy (R): 2% • Housing: stainless steel • Degree of protection according EN60529: IP67 • Sensing face: plastic 2 • Cable conductor cross section: 0,35 mm in diameters 6,5 ÷ 12 mm 2 0,75 mm in diameters 18 ÷ 45 mm • Marking: II 1D Ex iaD 20 T 130°C II 1G Ex ia IIC T4 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING L1 L2 L3 L4 L5 REFERENCES I brown + Rx blue --- mm mm mm mm mm mm mm KHz mm A • - 25 - - 25 4 6,5 5 1,5 DC6,5/4600LTA B • - 25 - - 25 4 M8 x 1 5 1,5 DC8/4600TA A-14 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-15 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES For high temperatures Ø 12-18-30-45 mm (-20°÷+110°C) • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B L5 L1 L2 d Housing B-1 L5 L1 L2 d Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 Technical data: ?d • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc with metal D (mm) 0 • Max ripple: 10% Sn (switching point) • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA Diameter M12 x 1 M18 x 1 M30 x 1,5 M45 x 1,5 without metal: ? 3 mA Size SW17 SW24 SW36 SW55 • Temperature range: - 20° ÷ + 110°C Nut • Max thermal drift of sensing distance S : ± 10% Thickness mm 4 4 5 5 r • Repeat accuracy (R): 2% Max tightening 15 35 80 70 torque Nm • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,35 mm in diameters 6,5 ÷ 12 mm 2 Materials: 0,75 mm in diameters 18 ÷ 45 mm • Cable: 2 m thermoplastic 140°C; 300 V; O.R. • Marking: II 1D Ex iaD 20 T 130°C • Housing: nickel plated brass II 1G Ex ia IIC T4 • Sensing face: plastic • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 I brown + Rx blue --- mm mm mm mm mm mm mm KHz mm • B - 30 - - 30 4 M12 x 1 5 2 DC12/4600TA • B - 1 - 30 - - 30 5 M18 x 1 1 5 DC18/4600TA • B - 1 - 35 - - 35 5 M30 x 1,5 0,3 10 DC30/4600TA • B - 1 - 35 - - 35 5 M45 x 1,5 0,3 20 DC45/4600TA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-15 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-16 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire • ATEX certified II 1GD for zone 0;20 • Associated apparatus not required - Cable output Housing J-1 L5 L2 LED d Housing G L5 L2 L3 LED d Diameter M18 x 1 M30 x 1,5 Size SW24 SW36 Nut Thickness mm 4 5 Max tightening 35 80 torque Nm Materials: • Cable: 2 m PVC; 90°C; 300 V; O.R. Technical data: • Housing: nickel plated brass • Supply voltage (U ): 7 ÷ 30 Vdc B • Sensing face: plastic • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 20° ÷ + 60°C • Max storage temperature: + 85°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 4% • Switching hysteresis max (H): 10% • Degree of protection: IP67 for diameter 30 mm IP68 for diameter 18 mm • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,50 mm • Marking: II 1D Ex maD 20 T80°C II 1G Ex ma II T6 • Certified IMQ 08 ATEX 002 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-18/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm KHz mA mm • J - 1 50 - - 50 5 M18 x 1 0,3 400 5 DCA18/4A09KSJMA DCA18/4A19KSJMA • G 50 10 - 60 6 M30x1,5 0,1 400 10 DCA30/4609KSMA DCA30/4619KSMA NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KSJMA) NO NC brown brown + + I I black black blue blue --- --- A-16 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-17 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire • ATEX certified II 2GD for zone 1;21 • Associated apparatus not required - Cable output • Housing B-3 L5 L2 L3 d LED Housing J-1 L5 L2 LED d Housing G L5 L2 L3 LED Technical data: d • Supply voltage (U ): 7 ÷ 30 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 20° ÷ + 60°C Diameter M12 x 1 M18 x 1 M30 x 1,5 • Max storage temperature: + 85°C Size SW17 SW24 SW36 • Max thermal drift of sensing distance S : ± 10% Nut r Thickness mm 4 4 5 • Repeat accuracy (R): 2% Max tightening • Switching hysteresis max (H): 10% 15 35 80 torque Nm • Degree of protection: IP67 for diameters 12 and 30 mm IP68 for diameter 18 mm Materials: • Switch status indicator: yellow LED • Cable: 2 m PVC; 90°C; 300 V; O.R. 2 • Cable conductor cross section: 0,35 mm for diameter 12 mm • Housing: nickel plated brass 2 0,50 mm for diameter 18 mm • Sensing face: plastic 2 0,50 mm for diameter 30 mm • Marking: II 2D Ex mbD 21 T80°C II 2G Ex mb II T6 • Certified IMQ 08 ATEX 002 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-18/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm KHz mA mm • B - 3 43 7 - 50 4 M12 x 1 0,8 200 2 DCA12/4609KSMB DCA12/4619KSMB • J - 1 50 - - 50 5 M18 x 1 0,3 400 5 DCA18/4A09KSJMB DCA18/4A19KSJMB • G 50 10 - 60 6 M30x1,5 0,1 400 10 DCA30/4609KSMB DCA30/4619KSMB NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KSMB) NO NC brown brown + + I I black black blue blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-17 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-18 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3 and 4-wire - diameters 6,5 - 8 mm • ATEX certified II 3GD for zone 2;22 • Cable output Housing A-3 L5 L1 L2 d LED Housing B-6 L5 L1 L2 L3 d LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: • Cable: 2 m PVC; 90°C; 300 V; O.R. • Housing: stainless steel Technical data: • Sensing face: plastic • Supply voltage (U ): 7 ÷ 30 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,15 mm in 4-wire versions 2 0,22 mm in 3-wire versions • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L5 PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue mm mm mm mm mm mm KHz mA mm --- A - 3 • - 45 - 45 3,5 6,5 4 100 1,5 DCA6,5/4609LKS3GD DCA6,5/4619LKS3GD DCA6,5/4629LKS3GD A - 3 • 5 40 - 45 3,5 6,5 3 100 2,5 DCA6,5/5609LKS3GD DCA6,5/5619LKS3GD DCA6,5/5629LKS3GD B - 6 • - 40 5 45 3,5 M8 x 1 4 100 1,5 DCA8/4609KS3GD DCA8/4619KS3GD DCA8/4629KS3GD B - 6 • 5 35 5 45 3,5 M8 x 1 3 100 2,5 DCA8/5609KS3GD DCA8/5619KS3GD DCA8/5629KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKS3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- A-18 A-18 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-19 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm • ATEX certified II 3GD for zone 2;22 • Cable output • Housing B-3 L5 L1 L2 L3 d LED Housing D L5 L1 L2 L3 L4 d LED Diameter M12 x 1 Size SW17 Nut Thickness mm 4 Max tightening 15 torque Nm Materials: • Cable: 2 m PVC; 90°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic Technical data: • Supply voltage (U ): 5 ÷ 40 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm in 3-wire versions 2 0,25 mm in 4-wire versions • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- mm mm mm mm mm mm mm KHz mA mm blue --- B - 3 • - 43 7 - 50 4 M12 x 1 2 100 2 DCA12/4609KS3GD DCA12/4619KS3GD DCA12/4629KS3GD D • - 50 10 20 80 4 M12 x 1 2 100 2 DCA12/4709KS3GD DCA12/4719KS3GD DCA12/4729KS3GD B - 3 • 7 36 7 - 50 4 M12 x 1 1,5 100 4 DCA12/5609KS3GD DCA12/5619KS3GD DCA12/5629KS3GD D • 7 43 10 20 80 4 M12 x 1 1,5 100 4 DCA12/5709KS3GD DCA12/5719KS3GD DCA12/5729KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KS3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-19 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-20 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - diameters 18 - 30 - 45 mm • ATEX certified II 3GD for zone 2;22 • Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 d Technical data: LED • Supply voltage (U ): diameter 18 mm: 5 ÷ 60 Vdc B diameters 30 - 45 mm: 7 ÷ 60 Vdc • Max ripple: 10% Diameter M18 x 1 M30 x 1,5 M45 x 1,5 • No-load supply current (I ): ? 10 mA o Size SW24 SW36 SW55 Nut • Voltage drop (U ): < 2,2 V d Thickness mm 4 5 4 • Temperature range: - 25° ÷ + 60°C Max tightening • Max thermal drift of sensing distance S : ± 10% 35 80 70 r torque Nm • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% Materials: • Degree of protection: IP67 • Cable: 2 m PVC; 90°C; 300 V; O.R. • Switch status indicator: yellow LED • Housing: nickel plated brass 2 • Cable conductor cross section: 0,50 mm in 3-wire version diameter 18 mm • Sensing face: plastic 2 0,35 mm in 4-wire version diameter 18 mm 2 0,50 mm for diameters 30 and 45 mm • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue mm mm mm mm mm mm mm KHz mA mm --- • B - 2 - 50 - - 50 5 M18 x 1 1 200 5 DCA18/4A09KS3GD DCA18/4A19KS3GD DCA18/4A29KS3GD • B - 2 10 40 - - 50 5 M18 x 1 1 200 8 DCA18/5A09KS3GD DCA18/5A19KS3GD DCA18/5A29KS3GD • G - 50 10 - 60 6 M30 x 1,5 0,8 200 10 DCA30/4609KS3GD DCA30/4619KS3GD DCA30/4629KS3GD • G 15 35 10 - 90 6 M30 x 1,5 0,4 200 15 DCA30/5609KS3GD DCA30/5619KS3GD DCA30/5629KS3GD • G - 1 10 50 10 - 60 6 M45 x 1,5 0,15 200 20 DCA45/4609KS3GD DCA45/4619KS3GD DCA45/4629KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KS3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- A-20 A-20 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-21 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. • ATEX certified II 3GD for zone 2;22 • Connector output M12x1 • Housing I-11 L5 L1 L2 L3 L4 2 M12 x 1 3 1 d 4 4 x LED Housing I-7 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Technical data: Housing I-2 L5 • Supply voltage (U ): see ordering references B • Max ripple: 10% L1 L2 L3 L4 • Rated operational current (I ): 100 mA e • No-load supply current (I ): ? 10 mA 2 o • Voltage drop (U ): < 1,5 V 3 1 d d M12 x 1 • Temperature range: - 25° ÷ + 60°C 4 • Max thermal drift of sensing distance S : ± 10% r 4 x LED • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 • Switch status indicator: yellow LED Size SW13 SW17 SW24 SW36 • Marking: II 3D Ex tc IIIC T80°C IP67 X Nut Thickness mm 4 4 4 5 II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload Max tightening 10 15 35 80 torque Nm • Protected against any wrong connection • Suppression of initial false impulse Materials: • Electromagnetic compatibility (EMC) according to EN60947-5-2 • Housing diameter 8 mm: stainless steel • According to: EN60079-0/EN60079-15/EN60079-31 • Housing diameters 12 ÷ 30 mm: nickel plated brass • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white 2 white V 3 blue 3 blue mm mm mm mm mm n° mm KHz mm --- --- 3 blue --- (min - max) • I - 11 - 40 12 8 60 8B -10 M8 x 1 7 ÷ 30 4 1,5 DCA8/4309KS3GD DCA8/43C9KS3GD DCA8/4329KS3GD • I - 11 5 35 12 8 60 8B -10 M8 x 1 7 ÷ 30 3 2,5 DCA8/5309KS3GD DCA8/53C9KS3GD DCA8/5329KS3GD • I - 7 - 43 15 8 66 8B -10 M12 x 1 5 ÷ 40 2 2 DCA12/4309KS3GD DCA12/43C9KS3GD DCA12/4329KS3GD • I - 7 7 36 15 8 66 8B -10 M12 x 1 5 ÷ 40 1,5 4 DCA12/5309KS3GD DCA12/53C9KS3GD DCA12/5329KS3GD • I - 12 - 50 19 8 77 8B -10 M18 x 1 5 ÷ 60 1 5 DCA18/4309KS3GD DCA18/43C9KS3GD DCA18/4329KS3GD • I - 12 10 50 19 8 87 8B -10 M18 x 1 5 ÷ 60 1 8 DCA18/5309KS3GD DCA18/53C9KS3GD DCA18/5329KS3GD • I - 2 - 65 17 8 90 8B -10 M30x1,5 7 ÷ 60 0,8 10 DCA30/4309KS3GD DCA30/43C9KS3GD DCA30/4329KS3GD • I - 2 15 50 17 8 90 8B -10 M30x1,5 7 ÷ 60 0,4 15 DCA30/5309KS3GD DCA30/53C9KS3GD DCA30/5329KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KS3GD) NO NC NO + NC 1 brown 1 brown 1 brown + + + I 4 black I I 4 black 2 white 2 white 3 blue 3 blue --- 3 blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-21 Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-22 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - SHORT SERIES • ATEX certified II 3GD for zone 2;22 • Cable output Housing A L5 L1 L2 d LED Housing B L5 L1 L2 d LED Housing B-4 L5 L1 L2 d LED Technical data: • Supply voltage (U ): see ordering references B • Max ripple: 10% L5 • No-load supply current (I ): ? 10 mA Housing B-5 o • Voltage drop (U ): ? 1,5 V L1 L2 d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% LED r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% d • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,22 mm in diameters 6,5 and 8 mm 2 0,35 mm in diameter 12 mm Diameter 2 M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 0,50 mm in diameters 18 and 30 mm Size SW13 SW17 SW24 SW36 • Marking: II 3D Ex tc IIIC T80°C IP67 X Nut II 3G Ex nAc IIC T6 X Thickness mm 4 4 4 5 • Protected against short-circuit and overload Max tightening 10 15 35 80 torque Nm • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameters 6,5 and 8 mm: stainless steel • Housing diameters 12 ÷ 30 mm: nickel plated brass • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue V (min - max) --- --- mm mm mm mm mm mm mm KHz mA mm • A - 30 - - 30 3,5 6,5 7 ÷ 30 4 200 1,5 DSA6,5/4609LKS3GD DSA6,5/4619LKS3GD • A 5 25 - - 30 3,5 6,5 7 ÷ 30 3 200 2,5 DSA6,5/5609LKS3GD DSA6,5/5619LKS3GD • B - 30 - - 30 3,5 M8 x 1 7 ÷ 30 4 200 1,5 DSA8/4609KS3GD DSA8/4619KS3GD • B 5 25 - - 30 3,5 M8 x 1 7 ÷ 30 3 200 2,5 DSA8/5609KS3GD DSA8/5619KS3GD • B - 4 - 30 - - 30 4 M12 x 1 7 ÷ 30 2 200 2 DSA12/4609KS3GD DSA12/4619KS3GD • B - 4 7 23 - - 30 4 M12 x 1 7 ÷ 30 1,5 200 4 DSA12/5609KS3GD DSA12/5619KS3GD • B - 5 - 30 - - 30 5 M18 x 1 5 ÷ 40 0,8 200 5 DSA18/4609KS3GD DSA18/4619KS3GD • B - 5 10 20 - - 30 5 M18 x 1 5 ÷ 40 0,6 200 8 DSA18/5609KS3GD DSA18/5619KS3GD • B - 5 - 35 - - 35 6 M30 x 1,5 7 ÷ 40 0,8 200 10 DSA30/4609KS3GD DSA30/4619KS3GD • B - 5 15 20 - - 35 6 M30 x 1,5 7 ÷ 40 0,4 200 15 DSA30/5609KS3GD DSA30/5619KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSA6,5/4608LKS3GD) NO NC brown brown + + I I black black blue blue --- --- A-22 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-23 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. - SHORT SERIES • ATEX certified II 3GD for zone 2;22 • Connector output M12 x 1 • Housing I L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-9 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L5 L1 L2 L3 L4 Technical data: 2 • Supply voltage (U ): see ordering references B d M12 x 1 3 1 • Max ripple: 10% 4 • No-load supply current (I ): ? 10 mA o 4 x LED • Voltage drop (U ): ? 1,5 V d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 • Repeat accuracy (R): 2% Size SW13 SW17 SW24 SW36 • Switching hysteresis max (H): 10% Nut Thickness mm • Degree of protection: IP67 4 4 4 5 • Switch status indicator: yellow LED Max tightening 10 15 35 80 torque Nm • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload Materials: • Protected against any wrong connection • Housing diameter 8 mm: stainless steel • Suppression of initial false impulse • Housing diameters 12 ÷ 30 mm: nickel plated brass • Electromagnetic compatibility (EMC) according to EN60947-5-2 • Sensing face: plastic • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC 1 brown 1 brown + + I I 4 black 2 white 3 blue 3 blue mm mm mm mm mm n° mm V (min - max) KHz mA mm --- --- • I - 26 13 8 47 6 - 8B -10 M8 x 1 7 ÷ 30 4 200 1,5 DSA8/4309KS3GD DSA8/43C9KS3GD • I 5 21 13 8 47 6 - 8B -10 M8 x 1 7 ÷ 30 3 200 2,5 DSA8/5309KS3GD DSA8/53C9KS3GD • I - 9 - 30 10 8 48 6 - 8B -10 M12 x 1 7 ÷ 30 2 200 2 DSA12/4309KS3GD DSA12/43C9KS3GD • I - 9 7 23 10 8 48 6 - 8B -10 M12 x 1 7 ÷ 30 1 200 4 DSA12/5309KS3GD DSA12/53C9KS3GD • I - 1 - 25 16 8 49 6 - 8B -10 M18 x 1 5 ÷ 40 0,8 200 5 DSA18/4309KS3GD DSA18/43C9KS3GD • I - 1 10 15 16 8 49 6 - 8B -10 M18 x 1 5 ÷ 40 0,6 200 8 DSA18/5309KS3GD DSA18/53C9KS3GD • I - 1 - 25 17 8 50 6 - 8B -10 M30 x 1,5 7 ÷ 40 0,8 200 10 DSA30/4309KS3GD DSA30/43C9KS3GD • I - 1 15 25 17 8 65 6 - 8B -10 M30 x 1,5 7 ÷ 40 0,4 200 15 DSA30/5309KS3GD DSA30/53C9KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSA8/4308KS3GD) NO NC 1 brown 1 brown + + I I 4 black 2 white 3 blue 3 blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-23 Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-24 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Cable output Housing B L5 L1 L2 L3 d LED Housing B-4 L5 L1 L2 L3 d LED Housing B-2 L5 L1 L2 LED d Technical data: • Supply voltage (U ): see ordering references B • Max ripple: 10% Housing B-5 L5 • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): ? 1,5 V L1 L2 L3 d • Temperature range: - 25° ÷ + 60°C LED • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 4% d • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,22 mm in diameters 6,5 and 8 mm 2 0,35 mm in diameter 12 mm Diameter 2 M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 0,50 mm in diameters 18 and 30 mm Size SW13 SW17 SW24 SW36 • Marking: II 3D Ex tc IIIC T80°C IP67 X Nut II 3G Ex nAc IIC T6 X Thickness mm 4 4 4 5 • Protected against short-circuit and overload Max tightening 10 15 35 80 torque Nm • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameters 6,5 and 8 mm: stainless steel • Housing diameters 12 ÷ 30 mm: nickel plated brass • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm mm V (min - max) Hz mA mm • B - 40 5 - 45 3,5 M8 x 1 7 ÷ 30 800 200 3 DCE8/4609KS3GD DCE8/4619KS3GD • B 5 35 5 - 45 3,5 M8 x 1 7 ÷ 30 400 200 4 DCE8/5609KS3GD DCE8/5619KS3GD • B - 4 - 43 7 - 50 4 M12 x 1 7 ÷ 40 800 200 4 DCE12/4609KS3GD DCE12/4619KS3GD • B - 4 7 36 7 - 50 4 M12 x 1 7 ÷ 40 600 200 6 DCE12/5609KS3GD DCE12/5619KS3GD • B - 2 - 50 - - 50 5 M18 x 1 7 ÷ 40 300 200 10 DCE18/4A09KS3GD DCE18/4A19KS3GD • B - 2 10 40 - - 50 5 M18 x 1 7 ÷ 40 200 200 14 DCE18/5A09KS3GD DCE18/5A19KS3GD • B - 5 - 50 10 - 60 6 M30 x 1,5 7 ÷ 40 100 200 20 DCE30/4609KS3GD DCE30/4619KS3GD • B - 5 15 35 10 - 60 6 M30 x 1,5 7 ÷ 40 100 200 28 DCE30/5609KS3GD DCE30/5619KS3GD NPN (negative switching) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: Use the above part number changing the last 9 with 8 (ie DCE8/4608LKS3GD) http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NO NC brown brown + + I I black black blue blue --- --- A-24 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting (*) Non flush mounting Cable diameter Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-25 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Connector output M12x1 • Housing I-11 L5 L1 L2 L3 L4 2 M12 x 1 3 1 d 4 4 x LED Housing I-7 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Technical data: • Supply voltage (U ): see ordering references B Housing I-2 • Max ripple: 10% L5 • Rated operational current (I ): 100 mA e L1 L2 L3 L4 • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): ? 1,5 V d 2 • Temperature range: - 25° ÷ + 60°C 3 1 • Max thermal drift of sensing distance S : ± 10% d M12 x 1 r • Repeat accuracy (R): 2% 4 • Switching hysteresis max (H): 10% 4 x LED • Degree of protection: IP67 • Switch status indicator: yellow LED • Marking: II 3D Ex tc IIIC T80°C IP67 X Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 II 3G Ex nAc IIC T6 X Size SW13 SW17 SW24 SW36 Nut • Protected against short-circuit and overload Thickness mm 4 4 4 5 • Protected against any wrong connection Max tightening • Suppression of initial false impulse 10 15 35 80 torque Nm • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 Materials: • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameter 8 mm: stainless steel • Housing diameters 12 - 30 mm: nickel plated brass Use in hazardous area according to instruction manuals • Sensing face: plastic ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white V 2 white mm mm mm mm mm n° mm KHz mm 3 blue 3 blue --- --- 3 blue (min-max) --- • I - 11 - 40 12 8 60 8B -10 M8 x 1 7 ÷ 30 0,8 3 DCE8/4309KS3GD DCE8/43C9KS3GD DCE8/4329KS3GD • I - 11 5 35 12 8 60 8B -10 M8 x 1 7 ÷ 30 0,4 4 DCE8/5309KS3GD DCE8/53C9KS3GD DCE8/5329KS3GD • I - 7 - 43 15 8 66 8B -10 M12 x 1 7 ÷ 40 0,8 4 DCE12/4309KS3GD DCE12/43C9KS3GD DCE12/4329KS3GD • I - 7 7 36 15 8 66 8B -10 M12 x 1 7 ÷ 40 0,6 6 DCE12/5309KS3GD DCE12/53C9KS3GD DCE12/5329KS3GD • I - 12 - 50 19 8 77 8B -10 M18 x 1 7 ÷ 40 0,3 10 DCE18/4309KS3GD DCE18/43C9KS3GD DCE18/4329KS3GD • I - 12 10 50 19 8 87 8B -10 M18 x 1 7 ÷ 40 0,2 14 DCE18/5309KS3GD DCE18/53C9KS3GD DCE18/5329KS3GD • I - 2 - 65 17 8 90 8B -10 M30 x 1,5 7 ÷ 40 0,1 20 DCE30/4309KS3GD DCE30/43C9KS3GD DCE30/4329KS3GD • I - 2 15 50 17 8 90 8B -10 M30 x 1,5 7 ÷ 40 0,1 28 DCE30/5309KS3GD DCE30/53C9KS3GD DCE30/5329KS3GD NPN (negative switching) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: Use the above part number changing the last 9 with 8 (ie DCE8/4308KS3GD) http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NO NC NO + NC 1 brown 1 brown 1 brown + + + I 4 black I I 4 black 2 white 2 white 3 blue 3 blue --- 3 blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-25 Housing Flush mounting (*) Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-26 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire • SHORT SERIES - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Cable output Housing A L5 L1 L2 d LED Housing B L5 L1 L2 d LED L5 Housing B-4 L1 L2 d LED Technical data: • Supply voltage (U ): see ordering references B • Max ripple: 10% L5 • No-load supply current (I ): ? 10 mA Housing B-5 o • Voltage drop (U ): ? 1,5 V d L1 L2 • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% LED r • Repeat accuracy (R): 4% • Switching hysteresis max (H): 10% d • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,22 mm in diameters 6,5 and 8 mm 2 0,35 mm in diameter 12 mm 2 Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 0,50 mm in diameters 18 and 30 mm • Marking: II 3D Ex tc IIIC T80°C IP67 X Size SW13 SW17 SW24 SW36 Nut II 3G Ex nAc IIC T6 X Thickness mm 4 4 4 5 • Protected against short-circuit and overload Max tightening 10 15 35 80 • Protected against any wrong connection torque Nm • Suppression of initial false impulse Materials: • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing diameters 6,5 and 8 mm: stainless steel • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameters 12 ÷ 30 mm: nickel plated brass • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm mm V (min - max) Hz mA mm • A - 30 - - 30 3,5 6,5 7 ÷ 30 800 200 3 DSE6,5/4609LKS3GD DSE6,5/4619LKS3GD • B - 30 - - 30 3,5 M8 x 1 7 ÷ 30 800 200 3 DSE8/4609KS3GD DSE8/4619KS3GD • B - 4 - 30 - - 30 4 M12 x 1 7 ÷ 30 800 200 4 DSE12/4609KS3GD DSE12/4619KS3GD • B - 4 7 23 - - 30 4 M12 x 1 7 ÷ 30 600 200 6 DSE12/5609KS3GD DSE12/5619KS3GD • B - 5 - 35 - - 35 5 M18 x 1 7 ÷ 40 300 200 10 DSE18/4609KS3GD DSE18/4619KS3GD • B - 5 10 25 - - 35 5 M18 x 1 7 ÷ 40 200 200 14 DSE18/5609KS3GD DSE18/5619KS3GD • B - 5 - 35 - - 35 6 M30 x 1,5 7 ÷ 40 100 200 20 DSE30/4609KS3GD DSE30/4619KS3GD • B - 5 15 20 - - 35 6 M30 x 1,5 7 ÷ 40 100 200 28 DSE30/5609KS3GD DSE30/5619KS3GD NPN (negative switching) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: Use the above part number changing the last 9 with 8 (ie DSE6,5/4608LKS3GD) http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NO NC brown brown + + I I black black blue blue --- --- A-26 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting (*) Non flush mounting Cable diameter Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-27 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. • SHORT SERIES - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Connector output M12x1 • Housing I L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-9 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L5 L1 L2 L3 L4 Technical data: • Supply voltage (U ): see ordering references B 2 • Max ripple: 10% • Rated operational current (I ): 200 mA d M12 x 1 3 1 e • No-load supply current (I ): ? 10 mA o 4 • Voltage drop (U ): ? 1,5 V 4 x LED d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 4% Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 • Switching hysteresis max (H): 10% Size SW13 SW17 SW24 SW36 • Degree of protection: IP67 Nut Thickness mm 4 4 4 5 • Switch status indicator: yellow LED Max tightening • Marking: II 3D Ex tc IIIC T80°C IP67 X 10 15 35 80 torque Nm II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload Materials: • Protected against any wrong connection • Housing diameter 8 mm: stainless steel • Suppression of initial false impulse • Housing diameters 12 ÷ 30 mm: nickel plated brass • Electromagnetic compatibility (EMC) according to EN60947-5-2 • Sensing face: plastic • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC 1 brown 1 brown + + I I 4 black 2 white 3 blue 3 blue mm mm mm mm mm n° mm V (min - max) Hz mm --- --- • I - 26 13 8 47 6 - 8B -10 M8 x 1 7 ÷ 30 800 3 DSE8/4309KS3GD DSE8/43C9KS3GD • I - 9 - 30 10 8 48 6 - 8B -10 M12 x 1 7 ÷ 30 800 4 DSE12/4309KS3GD DSE12/43C9KS3GD • I - 9 7 23 10 8 48 6 - 8B -10 M12 x 1 7 ÷ 30 600 6 DSE12/5309KS3GD DSE12/53C9KS3GD • I - 1 - 30 19 8 57 6 - 8B -10 M18 x 1 7 ÷ 40 300 10 DSE18/4309KS3GD DSE18/43C9KS3GD • I - 1 10 25 15 8 58 6 - 8B -10 M18 x 1 7 ÷ 40 200 14 DSE18/5309KS3GD DSE18/53C9KS3GD • I - 1 - 25 17 8 50 6 - 8B -10 M30 x 1,5 7 ÷ 40 100 20 DSE30/4309KS3GD DSE30/43C9KS3GD • I - 1 15 25 17 8 65 6 - 8B -10 M30 x 1,5 7 ÷ 40 100 28 DSE30/5309KS3GD DSE30/53C9KS3GD NPN (negative switching) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: Use the above part number changing the last 9 with 8 (ie DSE8/4308KS3GD) http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NO NC 1 brown 1 brown + + I I 4 black 2 white 3 blue 3 blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-27 Housing Flush mounting (*) Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Supply voltage ( U ) B Max switching frequency ( f ) Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-28 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - diameters 6,5 - 8 mm • ATEX certified II 3GD for zone 2;22 ÷ + • With extended temperature range (-20° 80°C) • Cable output Housing A-3 L5 L1 L2 d LED Housing B-6 L5 L1 L2 L3 d LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: • Cable: 2 m PVC; 105° C; 300 V; O.R. • Housing: stainless steel Technical data: • Sensing face: plastic • Supply voltage (U ): 7 ÷ 30 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 80°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue mm mm mm mm mm mm KHz mA mm --- --- • A - 3 - 45 - 45 4 6,5 4 50 1,5 DCA6,5/4609LKST3GD DCA6,5/4619LKST3GD • A - 3 5 40 - 45 4 6,5 3 50 2,5 DCA6,5/5609LKST3GD DCA6,5/5619LKST3GD • B - 6 - 40 5 45 4 M8 x 1 4 50 1,5 DCA8/4609KST3GD DCA8/4619KST3GD • B - 6 5 35 5 45 4 M8 x 1 3 50 2,5 DCA8/5609KST3GD DCA8/5619KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKST3GD) NO NC brown brown + + I I black black blue blue --- --- A-28 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-29 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm • ATEX certified II 3GD for zone 2;22 • ÷ + With extended temperature range (-20° 80°C) • Cable output • Housing B-3 L5 L1 L2 L3 d LED Housing D L5 L1 L2 L3 L4 d LED Diameter M12 x 1 Size SW17 Nut Thickness mm 4 Max tightening 15 torque Nm Materials: • Cable: 2 m PVC; 105° C; 300 V; O.R. • Housing: nickel plated brass Technical data: • Sensing face: plastic • Supply voltage (U ): 5 ÷ 40 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 20° ÷ + 80°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm mm KHz mA mm B - 3 • - 43 7 - 50 4 M12 x 1 2 50 2 DCA12/4609KST3GD DCA12/4619KST3GD D • - 50 10 20 80 4 M12 x 1 2 50 2 DCA12/4709KST3GD DCA12/4719KST3GD B - 3 • 7 36 7 - 50 4 M12 x 1 1,5 50 4 DCA12/5609KST3GD DCA12/5619KST3GD D • 7 43 10 20 80 4 M12 x 1 1,5 50 4 DCA12/5709KST3GD DCA12/5719KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KST3GD) NO NC brown brown + + I I black black blue blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-29 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-30 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3 and 4-wires - diameters 18 - 30 - 45 mm • ATEX certified II 3GD for zone 2;22 ÷ + • With extended temperature range (-20° 80°C) • Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 Technical data: d • Supply voltage (U ): diameter 18 mm: 5 ÷ 30 Vdc B diameters 30 - 45 mm: 10 ÷ 30 Vdc LED • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 2,2 V d Diameter M18 x 1 M30 x 1,5 M45 x 1,5 • Temperature range: - 25° ÷ + 80°C Size SW24 SW36 SW55 • Max thermal drift of sensing distance S : ± 10% r Nut • Repeat accuracy (R): 2% Thickness mm 4 8 5 • Switching hysteresis max (H): 10% Max tightening 35 80 70 torque Nm • Degree of protection: IP67 • Switch status indicator: yellow LED 2 Materials: • Cable conductor cross section: 0,50 mm in 3-wire version diameter 18 mm 2 • Cable: 2 m PVC; 105° C; 300 V; O.R. 0,35 mm in 4-wire version diameter 18 mm 2 • Housing: nickel plated brass 0,50 mm for diameters 30 and 45 mm • Sensing face: plastic • Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue mm mm mm mm mm mm mm KHz mA mm --- --- blue --- • B - 2 - 50 - - 50 5 M18 x 1 1 50 5 DCA18/4A09KST3GD DCA18/4A19KST3GD DCA18/4A29KST3GD • B - 2 10 40 - - 50 5 M18 x 1 1 50 8 DCA18/5A09KST3GD DCA18/5A19KST3GD DCA18/5A29KST3GD • G - 50 10 - 60 6 M30 x 1,5 0,8 50 10 DCA30/4609KST3GD DCA30/4619KST3GD DCA30/4629KST3GD • G 15 35 10 - 90 6 M30 x 1,5 0,4 50 15 DCA30/5609KST3GD DCA30/5619KST3GD DCA30/5629KST3GD • G - 1 10 50 10 - 60 6 M45 x 1,5 0,15 50 20 DCA45/4609KST3GD DCA45/4619KST3GD DCA45/4629KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KST3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- A-30 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-31 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. • ATEX certified II 3GD for zone 2;22 • ÷ + With extended temperature range (-20° 80°C) • Connector output M12x1 • Housing I-11 L5 L1 L2 L3 L4 2 M12 x 1 3 1 d 4 4 x LED Housing I-7 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Technical data: Housing I-2 • Supply voltage (U ): 10 ÷ 30 Vdc L5 B • Max ripple: 10% L1 L2 L3 L4 • Rated operational current (I ): ? 50 mA e • No-load supply current (I ): ? 10 mA o 2 • Voltage drop (U ): < 1,5 V d 3 1 d M12 x 1 • Temperature range: - 25° ÷ + 80°C 4 • Max thermal drift of sensing distance S : ± 10% r 4 x LED • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 • Marking: II 3D Ex tc IIIC T100°C IP67 X Size SW13 SW17 SW24 SW36 II 3G Ex nAc IIC T5 X Nut Thickness mm 4 4 4 5 • Protected against short-circuit and overload Max tightening • Protected against any wrong connection 10 15 35 80 torque Nm • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 Materials: • According to: EN60079-0/EN60079-15/EN60079-31 • Housing diameter 8 mm: stainless steel • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameters 12- 18 - 30 mm: nickel plated brass • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white 2 white 3 blue 3 blue mm mm mm mm mm n° mm KHz mm --- --- 3 blue --- I - 11 • - 40 12 8 60 8B -10 M8 x 1 4 1,5 DCA8/4309KST3GD DCA8/43C9KST3GD - I - 11 • 5 35 12 8 60 8B -10 M8 x 1 3 2,5 DCA8/5309KST3GD DCA8/53C9KST3GD - I - 7 • - 43 15 8 66 8B -10 M12 x 1 2 2 DCA12/4309KST3GD DCA12/43C9KST3GD - I - 7 • 7 36 15 8 66 8B -10 M12 x 1 1,5 4 DCA12/5309KST3GD DCA12/53C9KST3GD - I - 12 • - 50 19 8 77 8B -10 M18 x 1 1 5 DCA18/4309KST3GD DCA18/43C9KST3GD DCA18/4329KST3GD I - 12 • 10 50 19 8 87 8B -10 M18 x 1 1 8 DCA18/5309KST3GD DCA18/53C9KST3GD DCA18/5329KST3GD I - 2 • - 65 17 8 90 8B -10 M30 x 1,5 0,8 10 DCA30/4309KST3GD DCA30/43C9KST3GD DCA30/4329KST3GD I - 2 • 15 50 17 8 90 8B -10 M30 x 1,5 0,4 15 DCA30/5309KST3GD DCA30/53C9KST3GD DCA30/5329KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KST3GD) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white 2 white 3 blue 3 blue --- --- 3 blue --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-31 Housing Flush mounting Non flush mounting Female connector (see. page G -1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) ± 10% n Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-32 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3 and 4-wires - diameters 6,5 - 8 mm • ATEX certified II 3GD for zone 2;22 ÷ + • For high temperatures with LED (-20° 100°C) • Cable output Housing A-3 L5 L1 L2 d LED Housing B-6 L5 L1 L2 L3 d LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 10 torque Nm Materials: Technical data: • Cable: 2 m Thermoplastic; 140°C; 300 V; O.R. • Supply voltage (U ): 7 ÷ 30 Vdc B • Housing: stainless steel • Max ripple: 10% • Sensing face: plastic • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 100°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue mm mm mm mm mm mm KHz mA mm --- --- A - 3 • - 45 - 45 3,5 6,5 4 50 1,5 DCA6,5/4609LKSTB3GD DCA6,5/4619LKSTB3GD A - 3 • 5 40 - 45 3,5 6,5 3 50 2,5 DCA6,5/5609LKSTB3GD DCA6,5/5619LKSTB3GD B - 6 • - 40 5 45 3,5 M8 x 1 4 50 1,5 DCA8/4609KSTB3GD DCA8/4619KSTB3GD B - 6 • 5 35 5 45 3,5 M8 x 1 3 50 2,5 DCA8/5609KSTB3GD DCA8/5619KSTB3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKSTB3GD) NO NC brown brown + + I I black black blue blue --- --- A-32 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-33 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm • ATEX certified II 3GD for zone 2;22 • ÷ + For high temperatures with LED (-20° 100°C) • Cable output • Housing B-3 L5 L1 L2 L3 d LED Diameter M12 x 1 Size SW17 Nut Thickness mm 4 Max tightening 15 torque Nm Materials: • Cable: 2 m Thermoplastic; 140°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic Technical data: • Supply voltage (U ): 5 ÷ 40 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 100°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC brown brown + + I I black black blue blue --- --- mm mm mm mm mm mm mm KHz mA mm B - 3 • - 43 7 - 50 4 M12 x 1 2 50 2 DCA12/4609KSTB3GD DCA12/4619KSTB3GD B - 3 • 7 36 7 - 50 4 M12 x 1 1,5 50 4 DCA12/5609KSTB3GD DCA12/5619KSTB3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KSTB3GD) NO NC brown brown + + I I black black blue blue --- --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-33 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-34 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3 and 4-wires - diameter 18 - 30 - 45 mm • ATEX certified II 3GD for zone 2;22 ÷ + • For high temperatures with LED (-20° 100°C) • Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 Technical data: d • Supply voltage (U ): diameter 18 mm: 5 ÷ 30 Vdc B diameters 30 - 45 mm: 10 ÷ 30 Vdc LED • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 2,2 V d Diameter M18 x 1 M30 x 1,5 M45 x 1,5 • Temperature range: - 25° ÷ + 100°C Size SW24 SW36 SW55 • Max thermal drift of sensing distance S : ± 10% r Nut • Repeat accuracy (R): 2% Thickness mm 4 5 5 • Switching hysteresis max (H): 10% Max tightening 35 80 70 torque Nm • Degree of protection: IP67 • Switch status indicator: yellow LED 2 Materials: • Cable conductor cross section: 0,50 mm in 3-wire version diameter 18 mm 2 • Cable: 2 m Thermoplastic; 140° C; 300 V; O.R. 0,35 mm in 4-wire version diameter 18 mm 2 • Housing: nickel plated brass 0,50 mm in diameters 30 and 45 mm • Sensing face: plastic • Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L5 PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue mm mm mm mm mm mm KHz mA mm --- --- blue --- • B - 2 - 50 - 50 5 M18 x 1 1 50 5 DCA18/4A09KSTB3GD DCA18/4A19KSTB3GD DCA18/4A29KSTB3GD • B - 2 10 40 - 50 5 M18 x 1 1 50 8 DCA18/5A09KSTB3GD DCA18/5A19KSTB3GD DCA18/5A29KSTB3GD • G - 50 10 60 6 M30 x 1,5 0,8 50 10 DCA30/4609KSTB3GD DCA30/4619KSTB3GD DCA30/4629KSTB3GD • G 15 35 10 90 6 M30 x 1,5 0,4 50 15 DCA30/5609KSTB3GD DCA30/5619KSTB3GD DCA30/5629KSTB3GD • G - 1 10 50 10 60 6 M45 x 1,5 0,15 50 20 DCA45/4609KSTB3GD DCA45/4619KSTB3GD DCA45/4629KSTB3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KSTB3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- A-34 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-35 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. • ATEX certified II 3GD for zone 2;22 • ÷ + For high temperatures with LED (-20° 100°C) • Connector output M12x1 • Housing I-11 L5 L1 L2 L3 L4 2 M12 x 1 3 1 d 4 4 x LED Housing I-7 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Technical data: Housing I-2 • Supply voltage (U ): 10 ÷ 30 Vdc L5 B • Max ripple: 10% L1 L2 L3 L4 • Rated operational current (I ): ? 50 mA e • No-load supply current (I ): ? 10 mA o 2 • Voltage drop (U ): < 1,5 V d 3 1 d M12 x 1 • Temperature range: - 25° ÷ + 100°C 4 • Max thermal drift of sensing distance S : ± 10% r 4 x LED • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 • Marking: II 3D Ex tc IIIC T120°C IP67 X Size SW13 SW17 SW24 SW36 II 3G Ex nAc IIC T4 X Nut Thickness mm 4 4 4 5 • Protected against short-circuit and overload Max tightening • Protected against any wrong connection 10 15 35 80 torque Nm • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 Materials: • According to: EN60079-0/EN60079-15/EN60079-31 • Housing diameter 8 mm: stainless steel • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Housing diameters 12- 18 - 30 mm: nickel plated brass Use in hazardous area according to instruction manuals • Sensing face: plastic ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white 2 white 3 blue 3 blue mm mm mm mm mm n° mm KHz mm --- --- 3 blue --- I - 11 • - 40 12 8 60 8B -10 M8 x 1 4 1,5 DCA8/4309KSTB3GD DCA8/43C9KSTB3GD - I - 11 • 5 35 12 8 60 8B -10 M8 x 1 3 2,5 DCA8/5309KSTB3GD DCA8/53C9KSTB3GD - I - 7 • - 43 15 8 66 8B -10 M12 x 1 2 2 DCA12/4309KSTB3GD DCA12/43C9KSTB3GD - I - 7 • 7 36 15 8 66 8B -10 M12 x 1 1,5 4 DCA12/5309KSTB3GD DCA12/53C9KSTB3GD - I - 12 • - 50 19 8 77 8B -10 M18 x 1 1 5 DCA18/4309KSTB3GD DCA18/43C9KSTB3GD DCA18/4329KSTB3GD I - 12 • 10 50 19 8 87 8B -10 M18 x 1 1 8 DCA18/5309KSTB3GD DCA18/53C9KSTB3GD DCA18/5329KSTB3GD I - 2 • - 65 17 8 90 8B -10 M30 x 1,5 0,8 10 DCA30/4309KSTB3GD DCA30/43C9KSTB3GD DCA30/4329KSTB3GD I - 2 • 15 50 17 8 90 8B -10 M30 x 1,5 0,4 15 DCA30/5309KSTB3GD DCA30/53C9KSTB3GD DCA30/5329KSTB3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KSTB3GD) NO NC NO + NC 1 brown 1 brown 1 brown + + + I I I 4 black 4 black 2 white 2 white 3 blue 3 blue --- --- 3 blue --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-35 Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) ± 10% n Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-36 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. + a.c. 2-wires - Voltage 10 ÷ 50 V • ATEX certified II 3GD for zone 2;22 • Cable output Housing B-3 L5 L1 L2 L3 d LED Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d General features: These sensors are able to work with either direct or alternating current. Voltage drop and residual current are very low. They are not polarized and the load can be con- nected either of the leads. In many applications they can be used to replace mecha- Diameter M12 x 1 M18 x 1 M30 x 1,5 nical microswitches. Size SW17 SW24 SW36 Nut Thickness mm 4 4 5 Technical data: • Supply voltage (U ): 10 ÷ 50 Vdc/Vac Max tightening B 15 35 80 torque Nm • Electrical system frequency: 40 ÷ 60 Hz • Off-state current (I ): ? 1 mA r Materials: • Minimum operational current (I ): 5 mA m • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Voltage drop (U ): ? 5 V d • Housing: nickel plated brass • Temperature range: - 25° ÷ + 60°C • Sensing face: plastic • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm in diameter 12 mm 2 0,50 mm in diameter 18 mm 2 0,75 mm in diameter 30 mm • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC black black I I black black mm mm mm mm mm mm mm Hz Hz mA mm B - 3 • - 43 7 - 50 4 M12 x 1 800 25 100 2 AXM12/4600KS3GD AXM12/4610KS3GD B - 3 • 7 36 7 - 50 4 M12 x 1 600 25 100 4 AXM12/5600KS3GD AXM12/5610KS3GD B - 2 • - 58 12 - 70 5 M18 x 1 800 25 200 5 AXM18/4A00KS3GD AXM18/4A10KS3GD B - 2 • 10 48 12 - 70 5 M18 x 1 400 25 200 8 AXM18/5A00KS3GD AXM18/5A10KS3GD G • - 50 10 - 60 6 M30 x 1,5 400 25 200 10 AXM30/4600KS3GD AXM30/4610KS3GD G • 15 35 10 - 60 6 M30 x 1,5 200 25 200 15 AXM30/5600KS3GD AXM30/5610KS3GD A-36 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) in d.c. Max switching frequency ( f ) in a.c. Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-37 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING ANALOGUE LINEAR OUTPUT 4 ÷ 20 mA • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-2 L5 L1 L2 d Housing G L5 L1 L2 L3 d General features: These inductive proximity sensors provide an output current inversely or directly pro- Typical curves portional to the distance between sensing face and metal target. The output current is I (mA) dependent also on the target material. So the proximity sensors in addition to deter- 22 DCL18/5A09A DCL30/4609A 20 mining distance, displacements, vibrations and distortions can be used to recognize 18 16 DCL30/5609A the composition of metal and alloys. 14 12 Graph 1 10 8 Use of the sensor: 6 4 The current flowing through the load RL, generates a variation in voltage across the DCL18/4A09A 2 resistor for a suitable value of RL, it is possible to obtain voltage variations from one 1234567891012 14 16 18 d (mm) tenth to 20 V as can be seen in the tables. I (mA) DCL18/5A19A DCL30/4619A Technical data: 22 20 • Supply voltage: 10 ÷ 30 Vdc 18 16 DCL18/4A19A • Max ripple: 20% 14 12 Graph 2 • Output current range: 4 ÷ 20 mA 10 8 • Temperature range: - 10° ÷ + 60°C 6 4 DCL30/5619A • Max thermal drift: < 10% 2 1234567891012 14 16 18 d (mm) • Degree of protection: IP67 2 • Cable conductor cross section: 0,75 mm • Marking: II 1D Ex iaD 20 T80° C Connections II 1G Ex ia IIC T6 brown • Certified IMQ 08 ATEX 010 +Vcc Vout (V) RL (ohm) Vdc (min) • Protected against short-circuit and overload Vout blue 0,4 ... 2 100 15 • Protected against any wrong connection 2 ... 10 500 20 4...20mA 4 ... 20 1000 30 • Electromagnetic compatibility (EMC) according to EN60947-5-2 - Vcc • According to: EN60947-5-7/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 RL (max) = (Vdc-10) K? 20 Safety parameters: Diameter M18 x 1 M30 x 1,5 • Vi max: 30 V • Ii max: 100 mA Size SW24 SW36 Nut • Ci max: 5 nF Thickness mm 4 5 • Li max: 750 µH Max tightening 35 50 • Pi max: 660 mW torque Nm These sensors must be used in conjunction with associated Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. apparatus (See Sect. E) • Housing: nickel plated brass • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 INVERSELY DIRECTLY PROPORTIONAL PROPORTIONAL Graph 1 Graph 2 mm mm mm mm mm mm mm % mA Hz % mm • B - 2 - 50 - - 50 5 M18 x 1 3 4 250 0,5 2 ÷ 6 DCL18/4A09A DCL18/4A19A • B - 2 10 40 - - 50 5 M18 x 1 3 4 250 0,5 3 ÷ 8 DCL18/5A09A DCL18/5A19A • G - 50 10 - 60 5 M30 x 1,5 5 4 250 0,5 5 ÷ 12 DCL30/4609A DCL30/4619A • G 15 35 10 - 60 5 M30 x 1,5 5 4 250 0,5 7 ÷ 18 DCL30/5609A DCL30/5619A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-37 Housing Flush mounting Non flush mounting RL Cable diameter Body diameter ( d ) Maximum linearity error No- load supply current Max switching frequency ( f ) Repeat accuracy ( R ) Measurement rangeCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-38 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • ANALOGUE LINEAR OUTPUT 4 ÷ 20 mA • ATEX certified II 1GD for zone 0;20 • Connector output Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 Housing A-2 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 General features: These inductive proximity sensors provide an output current inversely or directly pro- Typical curves portional to the distance between sensing face and metal target. The output current is dependent also on the target material. So the proximity sensors in addition to deter- I (mA) 22 DCL18/5309A DCL30/4309A mining distance, displacements, vibrations and distortions can be used to recognize 20 the composition of metal and alloys. 18 16 DCL30/5309A 14 It is recommended to use ATEX certified connectors type C8B/002...A or 12 Graph 1 C10/002...A. 10 8 6 4 DCL18/4309A Use of the sensor: 2 The current flowing through the load RL, generates a variation in voltage across the 1234567891012 14 16 18 d (mm) resistor for a suitable value of RL, it is possible to obtain voltage variations from one I (mA) tenth to 20 V as can be seen in the tables. DCL18/5319A DCL30/4319A 22 20 18 Technical data: 16 DCL18/4319A 14 • Supply voltage: 15 ÷ 30 Vdc 12 Graph 2 10 • Max ripple: 20% 8 6 • Output current range: 4 ÷ 20 mA 4 DCL30/5319A 2 • Temperature range: - 10° ÷ + 60°C 1234567891012 14 16 18 d (mm) • Max thermal drift: < 10% • Degree of protection: IP67 • Marking: II 1D Ex iaD 20 T80° C Connections II 1G Ex ia IIC T6 (1) brown +Vcc Vout (V) RL (ohm) Vdc (min) • Certified IMQ 08 ATEX 010 Vout 0,04 ... 0,2 10 15 • Protected against short-circuit and overload (4) blue 0,4 ... 2 100 15 • Protected against any wrong connection 2 ... 10 500 20 4...20mA 4 ... 20 1000 30 • Electromagnetic compatibility (EMC) according to EN60947-5-2 - Vcc • According to: EN60947-5-7/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to IEN60068-2-27/EN60068-2-6 RL (max) = (Vdc-12) K? 20 Safety parameters: Diameter M18 x 1 M30 x 1,5 • Vi max: 30 V Size SW24 SW36 • Ii max: 100 mA Nut Thickness mm 4 5 • Ci max: 5 nF • Li max: 750 µH Max tightening 35 50 torque Nm • Pi max: 660 mW Materials: These sensors must be used in conjunction with associated • Housing: nickel plated brass apparatus (See Sect. E) • Sensing face: plastic Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 INVERSELY DIRECTLY PROPORTIONAL PROPORTIONAL Graph 1 Graph 2 mm mm mm mm mm n° mm % mA Hz % mm • I - 12 - 50 19 8 77 8B - 10 M18 x 1 3 4 250 0,5 2 ÷ 6 DCL18/4309A DCL18/4319A • I - 12 10 50 19 8 87 8B - 10 M18 x 1 3 4 250 0,5 3 ÷ 8 DCL18/5309A DCL18/5319A • A - 2 - 65 17 8 87 8B - 10 M30 x 1,5 5 4 250 0,5 5 ÷ 12 DCL30/4309A DCL30/4319A • A - 2 15 50 17 8 90 8B - 10 M30 x 1,5 5 4 250 0,5 7 ÷ 18 DCL30/5309A DCL30/5319A A-38 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting RL Female connector (see page G - 1) Body diameter ( d ) Maximum linearity error No- load supply current Max switching frequency ( f ) Repeat accuracy ( R ) Measurement rangeCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-39 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-14 L5 d LED Diameter M8 x 1 Size SW13 Nut Thickness mm 4 Max tightening 1 torque Nm Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: plastic General features: • Nuts: nickel plated brass With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally trig- gered and monitored by LED. The special material of the housing allows the use without additional protections against electrostatic charges. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Max ripple: 10% • Off-state current (I ): ? 1 mA r • Minimum operational current (I ): 2 mA m • Rated operational current (I ): 10 mA e • Voltage drop (U ) with load 10 mA: < 6,5 V d • Voltage drop (U ) with load 8 mA: < 5 V d • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated (*) Note: For non flush mounting version, it’s recommen- apparatus (See Sect. E) ded to leave the sensing face outside of metal for a length equal to a half of the external diameter. Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC brown brown I I + + blue blue Rx --- Rx --- mm mm mm mm mm mm mm KHz mm B -14 • - - - - 30 4 M8 x 1 3 1,5 DC8P/4600SA DC8P/4610SA B -14 • - - - - 30 4 M8 x 1 2 2,5 DC8P/5600SA DC8P/5610SA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-39 Housing Flush mounting Non flush mounting (*) Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-40 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING • NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B-15 L5 d LED Housing B-16 L5 General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sen- LED sors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally trig- d gered and monitored by LED. The special material of the housing allows the use without additional protections against electrostatic charges. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Max ripple: 10% Housing B-17 L5 • Off-state current (I ): ? 1 mA r • Minimum operational current (I ): 2 mA m • Rated operational current (I ): 10 mA e • Voltage drop (U ) with load 10 mA: < 6,5 V d LED • Voltage drop (U ) with load 8 mA: < 5 V d d • Temperature range: - 20° ÷ +60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 Diameter M12 x 1 M18 x 1 M30 x 1,5 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,35 mm in diameter 12 mm Size SW17 SW24 SW36 Nut 2 0,75 mm in diameters 18 and 30 mm Thickness mm 4 4 5 • Marking: II 1D Ex iaD 20 T80°C Max tightening 1 4 20 II 1G Ex ia IIC T6 torque Nm • Certified IMQ 08 ATEX 010 Materials: • Protected against short-circuit and overload • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Protected against any wrong connection • Housing: plastic • Electromagnetic compatibility (EMC) according to EN60947-5-2 • Nuts: nickel plated brass • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) (*) Note: For non flush mounting version, it’s recommen- ded to leave the sensing face outside of metal for a length equal to a half of the external diameter. Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 NO NC brown brown I I + + blue blue --- --- Rx Rx mm mm mm mm mm mm mm KHz mm • B-15 - - - - 30 4 M12 x 1 2 2 DC12P/4600KSA DC12P/4610KSA • B-15 - - - - 30 4 M12 x 1 1 4 DC12P/5600KSA DC12P/5610KSA • B -16 - - - - 30 5 M18 x 1 0,8 5 DC18P/4600KSA DC18P/4610KSA • B -16 - - - - 30 5 M18 x 1 0,6 8 DC18P/5600KSA DC18P/5610KSA • B -17 - - - - 35 5 M30 x 1,5 0,8 10 DC30P/4600KSA DC30P/4610KSA • B -17 - - - - 35 5 M30 x 1,5 0,4 15 DC30P/5600KSA DC30P/5610KSA A-40 A-40 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting (*) Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-41 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - TYPE Z • ATEX certified II 1GD for zone 0;20 • Cable output • 16 10 10,3 = = sensing 3,1 zone 2,8 Ø 3,1 Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 ?d with metal General features: D (mm) 0 Sn (switching point) This sensor has the same shape and holes position as a type V3 microswitch. The cable position allows the mounting on every side of the housing. The special mate- rial of the housing allows the use without additional protections against electrostatic charges. Model Type Z Technical data: Max tightening 1,5 torque Nm • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% Materials: • Consumption at 8,2 V with Rx = 1000 ? • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. with metal: ? 1 mA • Housing: plastic without metal: ? 3 mA • Temperature range: - 20° ÷ + 60°C : ± 10% • Max thermal drift of sensing distance S r • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,15 mm • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use in hazardous area according to instruction manuals ORDERING Sensing Max switching REFERENCES Nominal sensing Cable zone frequency distance ( S ) ± 10% diameter n diameter ( f ) I brown + Rx blue --- mm mm KHz mm • 3 9 1 2 DCZ/4600A • 3 9 0,8 4 DCZ/5600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-41 Flush mounting 28 Non flush mounting 6 22,5 2,75 3,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-42 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE T • ATEX certified II 1GD for zone 0;20 • Cable output 25 12 18 == sensing 16 zone 5,1 4 Ø 3,1 Typical curve I(mA) 4 without metal 3 2 1,75mA ?I 1,55mA 1 ?d General features: with metal D (mm) 0 These sensors are suitable for reduced mounting spaces. The special material of the Sn (switching point) housing allows the use without additional protections against electrostatic charges. Technical data: Model Type T • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% Max tightening 1 torque Nm • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA Materials: without metal: ? 3 mA • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Temperature range: - 20° ÷ + 60°C • Housing: plastic • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,35 mm • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use in hazardous area according to instruction manuals ORDERING Sensing Max switching REFERENCES Nominal sensing Cable zone frequency distance ( S ) ± 10% diameter n diameter ( f ) I brown + Rx blue --- mm mm KHz mm • 4 9 1 2 DCT/4700A • 4 9 0,8 4 DCT/5700A A-42 A-42 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Flush mounting 40 Non flush mounting 6,5 32 4 3,1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-43 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - TYPE X and Y • ATEX certified II 1GD for zone 0;20 • Cable output • Housing N 25 10 sensing zone 3 4 15 Housing N-2 15 30 sensing zone 4 Ø 4,2 Ø 8,2 6 General features: These sensors are suitable for reduced mounting spaces. The special material of the housing allows the use without additional protections against electrostatic charges. 19 Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc Typical curve • Max ripple: 10% I(mA) • Consumption at 8,2 V with Rx = 1000 ? 4 without metal with metal: ? 1 mA without metal: ? 3 mA 3 • Temperature range: - 20° ÷ + 60°C 2 : ± 10% • Max thermal drift of sensing distance S 1,75mA r ?I 1,55mA • Repeat accuracy (R): 2% 1 ?d • Degree of protection according EN60529: IP67 with metal 2 D (mm) 0 • Cable conductor cross section: 0,75 mm Sn (switching point) • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 Model Type X Type Y • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Max tightening • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 1 2,5 torque Nm Safety parameters: Materials: • Vi max: 13,5 V • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Ii max: 60 mA • Housing: plastic • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use in hazardous area according to instruction manuals ORDERING Sensing Max switching REFERENCES Cable Nominal sensing zone frequency diameter distance ( S ) ± 10% n diameter ( f ) I brown + Rx blue --- mm mm KHz mm • N 5 15 2 5 DCX/4700A • N 5 15 1 8 DCX/5700A • N - 2 5 23 0,8 10 DCY/4700A • N - 2 5 23 0,4 15 DCY/5700A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-43 Housing 50 50 14,5 10 Flush mounting Non flush mounting 8 7 Ø 7,3 Ø 4,2Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-44 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE P - 5 Position head • ATEX certified II 1G for zone 0 • Terminal block output 40 40 Ø 5,3 1 3 24 Pg13,5 30 34 Connections + RX 1 3 General features: 2 4 --- These sensors are described as “revolving head” because the actual sensor head, inside the plastic body, can be arranged in 5 different positions. To choose the desi- red direction it is sufficient to remove the cover, remove the head and positioning it according to the user’s particular requirements. The internal terminal block can be reached easily by removing the front cover. The particular plastic material allows the use without additional protections against electrostatic charges. Typical curve Technical data: I(mA) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc 4 without metal • Max ripple: 10% 3 • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA 2 1,75mA without metal: ? 3 mA ?I 1,55mA • Temperature range: - 20° ÷ + 60°C 1 ?d • Max thermal drift of sensing distance S : ± 10% with metal r D (mm) 0 • Repeat accuracy (R): 2% Sn (switching point) • Degree of protection according EN60529 (with fully locked gland): IP65 • Marking: II 1G Ex ia IIC T6 Model Type P • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 Max tightening 4 torque Nm • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Cable gland clamping 5 ÷ 12 range (mm) Safety parameters: Materials: • Vi max: 13,5 V • Housing: plastic • Ii max: 60 mA • Cable gland: nickel plated brass • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING Revolving Max switching REFERENCES Nominal sensing head frequency distance ( S ) ± 10% n diameter ( f ) I 1 brown + Rx 2 blue --- mm KHz mm • 35 0,2 15 DCP/4700A • 35 0,2 20 DCP/5700A A-44 A-44 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Flush mounting Non flush mounting 112 60 45 7,3Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-45 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - diameter 80 mm • ATEX certified II 1GD for zone 0;20 • Cable and connector output • Housing P 80 65 65 80 5,5 sensing zone 45 15 5,5 Housing P-1 80 65 65 80 5,5 sensing zone M12 x 1 45 15 General features: 5,5 Suitable for detection of large targets. The special material of the housing allows the use without additional protections against electrostatic charges. Typical curve Technical data: I(mA) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc 4 without metal • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? 3 with metal: ? 1 mA 2 1,75mA without metal: ? 3 mA ?I 1,55mA • Temperature range: - 20° ÷ + 60°C 1 ?d • Max thermal drift of sensing distance S : ± 10% r with metal D (mm) 0 • Repeat accuracy (R): 2% Sn (switching point) • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,75 mm • Marking: II 1D Ex iaD 20 T80° C Model Type DC80... II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 Max tightening 5 • Electromagnetic compatibility (EMC) according to EN60947-5-2 torque Nm • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. Safety parameters: • Housing: plastic • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES I 1 brown + Rx 2 blue --- mm n° mm KHz mm • P 5 - 80 0,5 40 DC80/5800A • P - 1 - 8B - 10 80 0,5 40 DC80/5300A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-45 Housing Flush mounting Non flush mounting Cable diameter Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-46 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE R • ATEX certified II 1GD for zone 0;20 • Cable and connector output Housing R-1 30 Ø 6,4 83 sensing zone 20 100 Housing R-2 30 M12 x1 Ø 6,4 sensing 83 zone General features: Suitable for detection of large targets. The special material of the housing allows the use without additional protections against electrostatic charges. 20 100 Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? Typical curve with metal: ? 1 mA I(mA) without metal: ? 3 mA 4 without metal • Temperature range: - 20° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r 3 • Repeat accuracy (R): 2% 2 1,75mA • Degree of protection according EN60529: IP67 ?I 2 1,55mA • Cable conductor cross section: 0,75 mm 1 ?d • Marking: II 1D Ex iaD 20 T80° C with metal D (mm) 0 II 1G Ex ia IIC T6 Sn (switching point) • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Model Type R Max tightening Safety parameters: 1,5 torque Nm • Vi max: 13,5 V • Ii max: 60 mA Materials: • Ci max: 100 nF • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Li max: 100 µH • Housing: plastic • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES I 1 brown + Rx 2 blue --- mm n° mm KHz mm • R - 1 5 - 65 0,3 55 DCR/5800A • R - 2 - 8B - 10 65 0,3 55 DCR/5300A A-46 A-46 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing 111 111 Flush mounting Non flush mounting 65 65 Cable diameter Female connector (see page G - 1) Sensing zone diameter 59 59 Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-47 RECTANGULAR INDUCTIVE ATEX SENSORS AMPLIFIED IN d.c. 3-wire - TYPE Z • ATEX certified II 3GD for zone 2;22 • Cable output • 16 10 10,3 = = sensing 3,1 zone 3 x LED 2,8 Ø 3,1 Model Type Z Max tightening 1,5 torque Nm Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: plastic General features: This sensor has the same shape and fixing holes as V3 standard microswitches. The particular cable position allows the mounting on every side of the housing. The spe- cial material of the housing allows the use without additional protections against elec- trostatic charges. The output status is indicated by LED visible from 3 sides. Technical data: • Supply voltage (U ): 7 ÷ 30 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,15 mm • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES Rated Nominal Sensing Max switching operational sensing Cable zone frequency current distance PNP (positive switching) diameter diameter ( f ) ( I ) ( S ) ± 10% e n NO NC brown brown + + I I black black blue blue mm mm mA KHz mm --- --- 3 9 200 2 2 DCAZ/4609KS3GD DCAZ/4619KS3GD • • 3 9 200 1,5 4 DCAZ/5609KS3GD DCAZ/5619KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAZ/4608KS3GD) NO NC brown brown + (*) Note: See mounting precautions at page 22 of BDC General + I I black black Catalogue or at this URL: blue blue --- --- http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-47 Flush mounting 28 Non flush mounting 6 22,5 2,75 3,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-48 RECTANGULAR INDUCTIVE ATEX SENSORS • AMPLIFIED IN d.c. 3 and 4-wires - TYPE T • ATEX certified II 3GD for zone 2;22 • Cable output 25 12 18 sensing == 16 zone 5,1 3 x LED 4 Ø 3,1 Model Type T Max tightening 1 torque Nm Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: plastic General features: These sensors are suitable for reduced mounting spaces. The special material of the housing allows the use without additional protections against electrostatic charges. Technical data: • Supply voltage (U ): 5 ÷ 40 Vdc B • Max ripple: 10% • No-load supply current (I ): ? 10 mA o • Voltage drop (U ): < 1,5 V d • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED 2 • Cable conductor cross section: 0,25 mm in 4-wire version 2 0,35 mm in 3-wire version • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue mm mm KHz mA mm --- • 4 9 1 200 2 DCAT/4709KS3GD DCAT/4719KS3GD DCAT/4729KS3GD • 4 9 0,8 200 4 DCAT/5709KS3GD DCAT/5719KS3GD DCAT/5729KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAT/4708KS3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- A-48 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Flush mounting 40 6,5 Non flush mounting Cable diameter Sensing zone diameter Max switching 32 frequency ( f ) Rated operational current ( I ) e Nominal sensing 4 distance (S ) ±10% n 3,1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-49 RECTANGULAR INDUCTIVE ATEX SENSORS AMPLIFIED IN d.c. 3 and 4-wires - TYPE X and Y • ATEX certified II 3GD for zone 2;22 • Cable output • Housing N 25 10 sensing zone 3 LED 4 15 Housing N-2 30 15 sensing zone 4 LED Ø 4,2 Ø 8,2 6 General features: 19 This series is suitable to the mounting in guideway. The flush mounting version can be placed side by side. The special material of the housing allows the use without addi- tional protections against electrostatic charges. Model Type X Type Y Technical data: Max tightening 1 2,5 torque Nm • Supply voltage (U ): 7 ÷ 60 Vdc B • Max ripple: 10% Materials: • No-load supply current (I ): ? 10 mA o • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Voltage drop (U ): < 2,2 V d • Housing: plastic • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% • Switching hysteresis max (H): 10% • Degree of protection: IP67 • Switch status indicator: yellow LED • Cable conductor cross section: 0,50 • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 (*) Note: See mounting precautions at page 22 of BDC General • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue mm n° mm KHz mA mm --- • N 5 - 15 1 200 5 DCAX/4609KS3GD DCAX/4619KS3GD DCAX/4929KS3GD • N 5 - 15 1 200 8 DCAX/5609KS3GD DCAX/5619KS3GD DCAX/5929KS3GD • N - 2 5 - 23 0,8 200 10 DCAY/4609KS3GD DCAY/4619KS3GD DCAY/4629KS3GD • N - 2 5 - 23 0,4 200 15 DCAY/5609KS3GD DCAY/5619KS3GD DCAY/5629KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAX/4608KS3GD) NO NC NO + NC brown brown brown + + + I I I black black black white blue blue --- --- blue --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-49 Housing 50 14,5 50 10 Flush mounting Non flush mounting Cable 8 diameter 7 Female connector (v. page G - 1) Ø 7,3 Ø 4,2 Sensing zone diameter Max switching frequency ( f ) Rated operational current ( I ) e Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-50 SLOT INDUCTIVE ATEX SENSORS • NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output Housing U Ø2 9 11 19 3,5 8 3 6,5 55 3 5 10 Housing Q Ø2 8,5 11 19 5 8 3 5,5 55 3 5 10 Housing S 24 General features: 12 These sensors are able to detect the presence of a metal blade into the slot. The swit- Ø 3,5 ching point of the output happens when about the 70% of internal faces is covered by the blade. The special material of the housing allows the use without additional 16,5 10,6 29,5 protections against electrostatic charges. 9,8 5 13 10,6 Technical data: 6 19 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc 15,5 8 30,5 • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? with metal: ? 1 mA without metal: ? 3 mA Typical curve • Temperature range: - 20° ÷ + 60°C • Max thermal drift of sensing distance S : ± 10% r I(mA) • Repeat accuracy (R): 2% 4 without metal • Degree of protection according EN60529: IP67 2 3 • Cable conductor cross section: 0,14 mm in types DF3,5/… and DF5/… 2 0,75 mm in type DF6/… 2 1,75mA • Marking: II 1D Ex iaD 20 T80° C ?I 1,55mA II 1G Ex ia IIC T6 1 ?d • Certified IMQ 08 ATEX 010 with metal D (mm) 0 • Electromagnetic compatibility (EMC) according to EN60947-5-2 Sn (switching point) • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Model Type DF3,5/... Type DF5/... Type DF6/... Safety parameters: • Vi max 13,5 V Max tightening 0,25 0,25 0,75 torque Nm • Ii max: 60 mA • Ci max: 100 nF Materials: • Li max: 100 µH • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Pi max: 200 mW • Housing: plastic These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES Cable Gap Max switching Minimum diameter width frequency ( f ) penetration Housing I brown + Rx blue --- mm mm KHz mm U 3 3,5 3 5 DF3,5/4600A Q 3 5 3 5 DF5/4600A S 5 5 1 9 DF6/4600A A-50 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-51 SLOT INDUCTIVE ATEX SENSORS NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing T 30 18 41 17 Ø 5 Housing V 50 30 80 24 Typical curve I(mA) 4 without metal General features: These sensors are able to detect the presence of a metal blade into the slot. The swit- 3 ching point of the output happens when about the 70% of internal faces is covered by the blade. The special material of the housing allows the use without additional 2 1,75mA ?I 1,55mA protections against electrostatic charges. 1 ?d with metal D (mm) Technical data: 0 Sn (switching point) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? Model Type DF15/... Type DF30/... with metal: ? 1 mA without metal: ? 3 mA Max tightening 4 5 • Temperature range: - 20° ÷ + 60°C torque Nm • Max thermal drift of sensing distance S : ± 10% r • Repeat accuracy (R): 2% Materials: • Degree of protection according EN60529: IP67 • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. 2 • Cable conductor cross section: 0,75 mm • Housing: plastic • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES Cable Gap Max switching Minimum diameter width frequency ( f ) penetration Housing I brown + Rx blue --- mm mm KHz mm T 5 15 0,8 16 DF15/4600A V 5 30 0,3 30 DF30/4600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com A-51 44 40 24,5 24,5 Ø 6,5 15,5 15 15,5 24 30 24Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX CAPACITIVE SENSORS NKS = capacitive NOT amplified d.c. NAMUR series P = plastic housing NKS 18 P/ 4 6 00A -5 PR 3 = with connector M12 x 1 6 = standard type cable output Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com B-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-3 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing C-1 L5 L2 L3 Trimmer d Housing G-2 L5 L2 L3 Trimmer d Typical curve I(mA) General features: 4 The capacitive sensors are used for detecting any material. Some materials, especial- ly if liquid or metallic, can be detected also through plastic or glass walls. They can 3 be used for various applications: level control in storage bins or tanks; survey filling 2 bottles; rain sensor; anti-vandalism tab; etc. The adjustment of sensing distance is 1,65 made by a potentiometer at the back of the housing. 1 D(mm) Technical data: Sn (switching point) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? Diameter M18 x 1 M30 x 1,5 with metal: ? 3 mA Size SW24 SW36 without metal: ? 1 mA Nut Thickness mm • Temperature range: - 20° ÷ + 60°C 4 5 • Max thermal drift of sensing distance S : ± 20% r Max tightening 35 80 torque Nm • Repeat accuracy (R): 4% • Degree of protection: IP65 2 Materials: • Cable conductor cross section: 0,75 mm • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Marking: II 1D Ex iaD 20 T80° C • Housing: nickel plated brass II 1G Ex ia IIC T6 • Sensing face: plastic • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW Reduction factor of the sensing distance for different target materials (T amb = 25°C) These sensors must be used in conjunction with associated Steel Glass PVC Cloth Paper Wood Water apparatus (See Sect. E) 1 0,5 0,5 0,15 0,1 0,25 1 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 C brown + Rx blue --- mm mm mm mm mm mm mm Hz mm • C - 1 - 50 10 - 60 5 M18 x 1 100 2 ÷ 5 NKS18/4600A • G - 2 - 50 10 - 60 5 M30 x 1,5 100 4 ÷ 10 NKS30/4600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com B-3 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10% (trimmable)Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-4 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Connector output Housing I-13 L5 L2 L3 L4 2 3 1 d M12 x 1 4 Housing A-5 L5 L2 L3 L4 2 3 1 d M12 x 1 4 Typical curve I(mA) 4 General features: The capacitive sensors are used for detecting any material. Some materials, especial- 3 ly if liquid or metallic, can be detected also through plastic or glass walls. They can be used for various applications: level control in storage bins or tanks; survey filling 2 1,65 bottles, etc. 1 Technical data: D(mm) Sn (switching point) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? Diameter M18 x 1 M30 x 1,5 with metal: ? 3 mA Size without metal: ? 1 mA SW24 SW36 Nut • Temperature range: - 20° ÷ + 60°C Thickness mm 4 5 • Max thermal drift of sensing distance S : ± 20% r Max tightening 35 80 • Repeat accuracy (R): 4% torque Nm • Degree of protection according EN60529: IP67 Materials: • Marking: II 1D Ex iaD 20 T80° C • Housing: nickel plated brass II 1G Ex ia IIC T6 • Sensing face: plastic • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW Reduction factor of the sensing distance for different target materials (T amb = 25°C) These sensors must be used in conjunction with associated Steel Glass PVC Cloth Paper Wood Water apparatus (See Sect. E) 1 0,5 0,5 0,15 0,1 0,25 1 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 C 1 brown + Rx 4 blue --- mm mm mm mm mm n° mm Hz mm • I - 13 - 50 19 8 77 8B - 10 M18 x 1 100 5 NKS18/4300A • A - 5 - 65 15 8 88 8B - 10 M30 x 1,5 100 10 NKS30/4300A B-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Flush mounting Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10%Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-5 CYLINDRICAL CAPACITIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing C-1 L5 L2 L3 Trimmer d Housing G-2 L5 L2 L3 Trimmer d Typical curve General features: I(mA) The capacitive sensors are used for detecting any material. Some materials, especial- 4 ly if liquid or metallic, can be detected also through plastic or glass walls. They can be used for various applications: level control in storage bins or tanks; survey filling 3 bottles; rain sensor; anti-vandalism tab; etc. The adjustment of sensing distance is 2 made by a potentiometer at the back of the housing. The special material of the hou- 1,65 sing allows the use without additional protections against electrostatic charges. 1 D(mm) Technical data: Sn (switching point) • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 ? Diameter M18 x 1 M30 x 1,5 with metal: ? 3 mA Size SW24 SW36 without metal: ? 1 mA Nut Thickness mm • Temperature range: - 20° ÷ + 60°C 4 5 • Max thermal drift of sensing distance S : ± 20% r Max tightening 4 20 torque Nm • Repeat accuracy (R): 4% • Degree of protection: IP65 2 Materials: • Cable conductor cross section: 0,75 mm • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Marking: II 1D Ex iaD 20 T80° C • Housing: plastic II 1G Ex ia IIC T6 • Nuts: nickel plated brass • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • Vi max: 13,5 V • Ii max: 60 mA • Ci max: 100 nF • Li max: 100 µH • Pi max: 200 mW Reduction factor of the sensing distance for different target materials (T amb = 25°C) These sensors must be used in conjunction with associated Steel Glass PVC Cloth Paper Wood Water apparatus (See Sect. E) 1 0,5 0,5 0,15 0,1 0,25 1 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 C brown + Rx blue --- mm mm mm mm mm mm mm Hz mm • C - 1 - 50 10 - 60 5 M18 x 1 100 2 ÷ 5 NKS18P/4600A • G - 2 - 50 10 - 60 5 M30 x 1,5 100 4 ÷ 10 NKS30P/4600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com B-5 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max switching frequency ( f ) Nominal sensing distance ( S ) n ± 10% (trimmable)Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX MAGNETIC SENSORS BMS = activated by external magnet BMSN = activated by ferromagnetic target with NAMUR output Diameter of cylindrical sensors. For other types, change the number with the following: W = rectangular plastic 19 x 28,5 x 10,5 mm BMSN 12/ 4600 A -5 PR A = category 1G - 1D Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com C-1Catalogo Atex 2013 Inglese_03 14-04-2013 20:54 Pagina C-3 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING REED CONTACT 2-wire • ATEX certified II 1GD for zone 0;20 • Detection of external magnets • Associated apparatus not required - Cable output • Housing B-10 L5 magnet SW7 N S d (S) (N) Housing B-12 L5 magnet SW10 N S d (S) (N) Diameter M8 x 1 M12 x 1 Size SW13 SW17 Nut Thickness mm 4 4 Max tightening 10 20 torque Nm Materials: • Cable: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. General features: • Housing: stainless steel These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. Reed con- tacts are able to drive directly dc loads (PNP/NPN). The extremely strong construction allows the use in the most difficult conditions even with high pressures on the housing. Technical data: • Working voltage: 5 ÷ 30 Vdc • Output logic: normally open • Contact resistance max: 0,1 ? • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 2 • Cable conductor cross section: 0,35 mm • Pressure on the front side max: 150 bar • Marking: II 1D Ex maD 20 T80° C II 1G Ex ma II T6 • Certified IMQ 08 ATEX 002 X • According to: EN60079-0/EN60079-18/EN60079-26 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 brown M blue mm mm mm mm mm mm mm KHz mA B -10 - - - - 35 4 M8 x 1 0,5 500 BMS8/4600MA B -12 - - - - 35 4 M12 x 1 0,5 500 BMS12/4600MA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com C-3 Housing Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-4 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING • REED CONTACT 2-wire - NAMUR output • ATEX certified II 1GD for zone 0;20 • Detection of external magnets • Cable output Housing B-10 L5 magnet SW7 N S d (S) (N) Housing B-12 L5 magnet SW10 N S d (S) (N) General features: These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the Diameter M8 x 1 M12 x 1 power of the magnet (see page C-9), which must be ordered separately. The output Size impedance is compatible with NAMUR standard, allowing the diagnostic of the con- SW13 SW17 Nut nections. Thickness mm 4 4 The extremely strong construction allows the use in the most difficult conditions even Max tightening 10 20 torque Nm with high pressures on the housing. Materials: Technical data: • Cable: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Working voltage: 7,7 ÷ 9 Vdc • Housing: stainless steel • Output logic: normally open • Consumption at 8,2 V with Rx = 1000 ? activated: ? 3 mA non-activated: ? 1 mA • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 2 • Cable conductor cross section: 0,35 mm • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: 13,5 Vdc • Ii max: 60 mA • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 brown M blue mm mm mm mm mm mm mm KHz mA B -10 - - - - 35 4 M8 x 1 0,5 100 BMSN8/4600A B -12 - - - - 35 4 M12 x 1 0,5 100 BMSN12/4600A C-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Housing Cable diameter Body diameter ( d ) Max switching frequency ( f ) Rated operational current ( I ) e Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-5 RECTANGULAR MAGNETIC ATEX SENSORS REED CONTACT 2-wire • ATEX certified II 1GD for zone 0;20 • For pneumatic cylinders • Cable output • General features: This sensor detects the position of the magnetic ring inside a standard pneumatic cylinder with a T slot. The sensor remains completely recessed and thus mechanically protected. Reed contact provides for a direct driving of DC (PNP/NPN). Technical data: • Working voltage: 10 ÷ 30 Vdc • Output logic: normally open • Contact resistance max: 0,1 ? • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 2 • Cable conductor cross section: 0,14 mm • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: 30 Vdc • Ii max: 100 mA • Pi max: 750 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Materials: • Cable: PVC CEI 20-22 II; 90°C; 300V • Sensor: plastic Use in hazardous area according to instruction manuals Housing S-1 29,2 4,4 27,2 5 6,1 Ø 3 hexagonal screw 1,3 mm 2000 3 ORDERING REFERENCES Rated operational Max switching Cable current frequency diameter ( I ) ( f ) e brown M blue mm mA KHz S - 1 3 100 0,5 BMS/4600A Note: different cable lengths must be specified at the end of the code. Ex: BMS/4600A -1 for 1m of cable with connector. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com C-5 HousingCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-6 RECTANGULAR MAGNETIC ATEX SENSORS • REED CONTACT 2-wire - NAMUR output • ATEX certified II 1GD for zone 0;20 • For pneumatic cylinders • Cable output General features: This sensor detects the position of the magnetic ring inside a standard pneumatic cylinder with a T slot. The sensor remains completely recessed and thus mechanically protected. The output impedance is compatible with NAMUR standard, allowing the diagnostic of the connections. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Output logic: normally open • Consumption at 8,2 V with Rx = 1000 ? activated: ? 3 mA non-activated: ? 1 mA • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 2 • Cable conductor cross section: 0,14 mm • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60957-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: 13,5 Vdc • Ii max: 60 mA • Pi max: 200 mW These sensors must be used in conjunction with associated Materials: apparatus (See Sect. E) • Cable: PVC CEI 20-22 II; 90°C; 300V • Sensor: plastic Use in hazardous area according to instruction manuals Housing S-1 29,2 4,4 27,2 5 6,1 Ø 3 hexagonal screw 1,3 mm 2000 3 ORDERING REFERENCES Max switching Cable frequency diameter ( f ) brown M blue mm KHz S - 1 3 0,5 BMSN/4600A Note: different cable lengths must be specified at the end of the code. Ex: BMS/4600A -1 for 1m of cable with connector. C-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com HousingCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-7 RECTANGULAR MAGNETIC ATEX SENSORS REED CONTACT 2-wire • ATEX certified II 1GD for zone 0;20 • TYPE Z and W • Cable output • Housing Z-1 16 10 10,3 3,1 sensing zone 2,8 Ø 3,1 Housing W-1 10,5 9,5 9,5 3,4 General features: These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. 4,5 The special material of the housing allows the use without additional protections against electrostatic charges. Ø 6,5 Technical data: • Working voltage: 10 ÷ 30 Vdc • Output logic: normally open Model Type Z Type W • Contact resistance max: 0,1 ? Max tightening • Operate time max: 1 ms 1,5 0,75 torque Nm • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C Materials: • Degree of protection: IP67 • Cable: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. 2 • Cable conductor cross section: 0,14 mm in Type Z • Housing: plastic 2 0,35 mm in Type W • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: 30 Vdc • Ii max: 100 mA • Pi max: 750 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES Rated operational Max switching Cable current frequency diameter NO ( I ) ( f ) Housing e brown M blue mm KHz mA Z - 1 3 0,5 100 BMSZ/4600A W - 1 5 0,5 100 BMSW/4600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com C-7 28 20,5 11,5 4,5 22,5 2,75 3,5 5 28,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-8 RECTANGULAR MAGNETIC ATEX SENSORS • REED CONTACT 2-wire - NAMUR output • ATEX certified II 1GD for zone 0;20 • TYPE Z and W • Cable output Housing Z-1 16 10 10,3 3,1 sensing zone 2,8 Ø 3,1 Housing W-1 10,5 9,5 9,5 3,4 General features: These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. The output impedance complies with the NAMUR standard, allowing the diagnostic of the connections. The special material of the housing allows the use without additional protections against electrostatic charges. 4,5 Technical data: • Working voltage: 7,7 ÷ 9 Vdc Ø 6,5 • Output logic: normally open • Consumption at 8,2 V with Rx = 1000 ? activated: ? 3 mA non-activated: ? 1 mA Model Type Z Type W • Operate time max: 1 ms Max tightening • Release time max: 0,4 ms 1,5 0,75 torque Nm • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 Materials: 2 • Cable conductor cross section: 0,14 mm in Type Z • Cable: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. 2 0,35 mm in Type W • Housing: plastic • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60957-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: 13,5 Vdc • Ii max: 60 mA • Pi max: 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES Rated operational Max switching Cable current frequency diameter NO ( I ) ( f ) Housing e brown M blue mm KHz mA Z - 1 3 0,5 100 BMSNZ/4600 W - 1 5 0,5 100 BMSNW/4600 C-8 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com 28 20,5 11,5 4,5 22,5 2,75 3,5 5 28,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-9 MAGNETIC ATEX SENSORS MAGNETS FOR SENSORS • Fig. A - Nickel plated Ld Ø Fig. B - Epoxy encapsulated L d Ø Fig. C - Epoxy coated L Fig. D - Epoxy encapsulated 16 10 10,3 3,1 General features: These magnets can be used as actuators for all the magnetic sensors which need an external activation magnet. They’re suitable for applications up to 70° C. For particu- lar applications contact our technical office. In the ordering reference table there are approximate detection distances obtained 2,8 Ø 3,1 with different types of BDC sensors. The special material of the housing allows the use without additional protections against electrostatic charges. Fig. E - Epoxy encapsulated 10,5 9,5 9,5 Use in hazardous area according to instruction manuals 3,4 3,3 Materials: N • Housing B: stainless steel • Housing D - E: plastic Housing B C D S Size SW13 - - Nut Thickness mm 4 - - 4,5 Max tightening 10 x 1,5 torque Nm Diameter L DETECTION DISTANCE ORDERING Fig. REFERENCES With Reed With solid state mm mm sensors sensors A 5 3 6 15 MAG-T53 A 8 3,6 13 22 MAG-T83 A 10 5 20 30 MAG-T105 B M8x1 20 10 17 MAG-M820 C 13 6 25 45 MAG-TF136 D - - 13 22 MAG-Z -A E - - 15 27 MAG-W-A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com C-9 28 d Ø Ø 4,2 28,5 22,5 Ø 9,5 20,5 11,5 4,5 2,75 3,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX SPEED SENSORS DSD = with integrated control in d.c. ASD = with integrated control in a.c. Diameter DSD 18 / 4 3 0 9 KS 3GD -5 3 = with connector M12 x 1 6 = standard type cable output K = protection against short circuit and overload S = LED output status Cable length (if required different than standard 2m) BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com D-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-3 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Speed sensors with integrated control function • 3-wire - d.c. • ATEX certified II 3GD for zone 2;22 • Connector output M12 x 1 • Housing I-7 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-12 L5 L1 L2 L3 L4 2 3 1 d M12 x 1 4 4 x LED Housing I-2 L5 L1 L2 L3 L4 General features: 2 These sensors enable the control with extremely high precision the rotation of a 3 1 d toothed wheel or reference marks, switching off the load or giving an alarm in case M12 x 1 the speed falls below the minimum threshold. Thanks to the extremely wide measu- 4 ring range they can be even used to control repetitive operations, signalling in case 4 x LED of unwanted stops. Further delays or other special functions may be implemented upon specific request. Diameter M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 The output is protected against wrong connection, overvoltages on line, and short cir- Size SW13 SW17 SW24 SW36 cuit of the load. The connection is with a 4-wire M12x1 connector which must be Nut ordered separately. Thickness mm 4 4 4 5 Max tightening 10 15 35 80 torque Nm Technical data: • Working voltage: 10 ÷ 30 Vdc Materials: • Max ripple: 10% • Housing diameter 8 mm: stainless steel • No-load supply current: <15 mA • Housing diameters 12 - 18 - 30 mm: nickel plated brass • Rated operational current (I ): 100 mA e • Sensing face: plastic • Voltage drop: < 1,5 V • Switching hysteresis (H): <10% Sn • Repeat accuracy (R ): < 2% Sn • Maximum detectable interval (between two pulses): 2 min • Detectable start-up time (T1): 0 ÷1 min (default 2 sec.) • Temperature range: - 25° ÷ + 60°C • Max thermal drift of sensing distance S : ±10% n • Degree of protection: IP67 • Status indicator: yellow LED = out ON; frequency over the threshold • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 PNP (positive switching) 1 brown + I 2 white 4 black teach 10 ÷ 30 Vdc 3 blue mm mm mm mm mm n° mm KHz mm --- • I - 7 - 43 15 8 66 8B -10 M12 x 1 1 2 DSD12/4309KS3GD • I - 7 7 36 15 8 66 8B -10 M12 x 1 1 4 DSD12/5309KS3GD • I - 12 - 50 19 8 77 8B -10 M18 x 1 1 5 DSD18/4309KS3GD • I - 12 10 50 19 8 87 8B -10 M18 x 1 1 8 DSD18/5309KS3GD • I - 2 - 65 17 8 90 8B -10 M30 x 1,5 0,8 10 DSD30/4309KS3GD • I - 2 15 50 17 8 90 8B -10 M30 x 1,5 0,4 15 DSD30/5309KS3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com D-3 Housing Flush mounting (*) Non flush mounting Female connector (see page G - 1) Body diameter ( d ) Max detectable frequency Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-4 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Example of application Motor Motor Power Use of the sensor: Sensor 1 Brown + On power on, the yellow LED lights and the output switches to the ON state, driving 2 White the relay, which will drive the motor. After a start up delay time (T1) the sensor mea- Teach 10 ÷ 30 Vdc 4 Black sures the speed of the motor and compares it to the threshold value. 3 Blue --- If the speed is under the threshold value, the output goes OFF, turning off the LED. The minimum threshold can be either factory preset or can be programmed from the sensor application with no need to perform any measurement. Threshold self-teaching procedure: Procedure 1 RPM There are two different ways to perform the self-teaching of the threshold: 1- Acquisition of start up time and calculation of the Max threshold from the maximum speed: th = (Max-20%) a) connect the Teach input (white) to the positive of power supply (brown) before turning on the power T T1 b) Turn on the power supply to the machine and to the sensor and wait the speed gets the nominal value. The yellow LED will flash 4 times to indicate the OUT acquisition complete c) Turn off the power supply d) At this stage the sensor has acquired the start up time (T1) and calculated the ON threshold as the maximum value of the speed reduced of -20% OFF T e) Disconnect the Teach in from the positive of power supply before running the machine again. 2 - Acquisition of a known threshold Procedure 2 (start up time is not modified): RPM a) Turn the power supply on to the machine and sensor and accelerate to the speed you want to get as threshold (th) b) Connect temporarily the Teach input (white) to the positive of power supply. th This operation can be easily done with a push-button on the operator panel of the machine. T c) At this stage the current speed becomes the minimum threshold (th), under of Teach which the sensor goes in OFF state. Both of the procedures can be repeated unlimited times. UB 0V T OUT ON T D-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-5 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Speed sensors with integrated control function • 2-wire - a.c. • ATEX certified II 3GD for zone 2;22 • Cable output • Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d General features: These sensors enable the control with extremely high precision the rotation of a toothed wheel or reference marks, switching off the load in case of the speed falls below the minimum threshold. Thanks to the extremely wide measuring range they Diameter M18 x 1 M30 x 1,5 can be even used to control repetitive operations, signalling in case of unwanted Size SW24 SW36 stops. They are able to drive directly a.c. relays from 90 to 240 Vac with no need Nut Thickness mm 4 5 external power supply or amplifiers. Further delays or other special functions may be implemented upon specific request. Max tightening 35 80 torque Nm The output is protected against wrong connection, overvoltages on line, and short cir- cuit of the load. Materials: • Cable: 2m PVC - CEI 2022 II- 90°C 300V-O.R. Technical data: • Housing: nickel plated brass • Working voltage: 90 ÷ 240 Vac • Sensing face: plastic • Electrical system frequency: 40 ÷ 60 Hz • Off-state current at 220 V: <2,2 mA • Minimum operational current: 8 mA • Voltage drop: <8V • Switching hysteresis (H): <10% Sn • Repeat accuracy (R): <2% Sn • Maximum detectable interval (between two pulses): 2 min • Detectable start-up time (T1): 0 ÷1 min (default 2 sec.) • Temperature range: -25° ÷ +60°C • Max thermal drift of sensing distance S : ±10% n • Degree of protection: IP67 2 • Cable conductor cross section: 0,50mm • Status indicator: yellow LED = out ON; frequency over the threshold red LED = out OFF; frequency under the threshold blinking red LED = out OFF; short circuit on the output • Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X • Protected against short-circuit and overload • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-15/EN60079-31 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Class 2 equipment according to EN61140 Use in hazardous area according to instruction manuals ORDERING REFERENCES L1 L2 L3 L4 L5 brown I black teach 90 ÷ 240 Vac blue mm mm mm mm mm mm mm Hz mA mm C • - 50 - - 50 5 M18 x 1 800 200 5 ASD18/4A09KS3GD C • 10 40 - - 50 5 M18 x 1 400 200 8 ASD18/5A09KS3GD G • - 50 10 - 60 6 M30 x 1,5 400 200 10 ASD30/4609KS3GD G • 15 35 10 - 60 6 M30 x 1,5 200 200 15 ASD30/5609KS3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com D-5 Housing Flush mounting Non flush mounting Cable diameter Body diameter ( d ) Max detectable frequency Rated operational current ( I ) e Nominal sensing distance (S ) ±10% nCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-6 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Example of application Motor Use of the sensor: Sensor Brown On power on, the yellow LED lights and the output switches to the ON state, driving Black the relay, which will drive the motor. After a start up delay time (T1) the sensor mea- Teach 90 ÷ 240 Vac sures the speed of the motor and compares it to the threshold value. If the speed is Blue under the threshold value, the output goes OFF, giving an alarm indication with the red LED. The minimum threshold can be either factory preset or can be programmed from the sensor application with no need to perform any measurement. Procedure 1 RPM Threshold self-teaching procedure: Max There are two different ways to perform the self-teaching of the threshold: th = (Max-20%) 1 - Acquisition of start up time and calculation of the threshold from the maximum speed: T T1 a) connect the Teach input (black) to the brown before turning on the power OUT b) Turn on the power supply to the machine and to the sensor and wait the speed gets the nominal value c) Turn off the power supply ON d) At this stage the sensor has acquired the start up time (T1) and calculated the OFF T threshold as the maximum value of the speed reduced of -20% e) Disconnect the Teach in from the brown wire before running the machine Procedure 2 again. RPM 2 - Acquisition of a known threshold (start up time is not modified): a) Turn the power supply on to the machine and sensor and accelerate to the th speed you want to get as threshold (th). b) Connect temporarily the Teach input (black) to the brown wire. This operation T can be easily done with a push-button on the operator panel of the machine. Teach c) At this stage the current speed becomes the minimum threshold (th), under of which the sensor goes in OFF state. Both of the procedures can be repeated unlimited times. UB 0V T OUT ON T D-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-1 HOW TO INTERPRETE THE ORDERING REFERENCES AMPLIFIERS AND REPEATERS FOR ATEX SENSORS 0 = supply voltage 24 Vdc 1 = supply voltage 115-230 Vac 3 = Inputs for contacts or NAMUR proximity sensors 1 = Analogue input 4-20 mA D 1 0 3 0 S 0 = relay output 1 = optocoupled static output S = single output D = 2 outputs Q = 4 outputs BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-3 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Relay Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels • 13 2 4 57 6 8 PWR ON 12 STATUS /FAULT 13 14 15 16 114,5 22,5 Technical Data: • Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ? 5 Vpp General Description: The Switch/Proximity Detector Repeater type D1030 is a DIN Rail • Isolation (Test Voltage): I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; unit with one or two independent channels. The unit can be confi- Out/Supply 1.5 KV; Out/Out 1.5 KV gured for contact or proximity detector, NO or NC and for NE or ND SPDT relay output contact. • Input switching current levels: ON ? 2,1 mA, Each channel enables a Safe Area load to be controlled by a swit- OFF ? 1,2 mA, ch, or a proximity detector, located in Hazardous Area. switch current ? 1,65 mA ± 0,2 mA hysteresis D1030D dual channel type has two independent input channels • Fault current levels: open fault ? 0,2 mA, and actuates the corresponding output relay. Two actuation modes short fault ? 6,8 mA, can be independently DIP switch configured on each input chan- (when enabled both faults de-energize channel relay with dual channel unit nel: NO input/NE relay or NO input/ND relay. D1030D or actuate fault relay with single channel unit D1030S). Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable: fault detection • Input equivalent source: 8 V 1 K? typical can be enabled (in case of fault it de-energizes the corresponding (8 V no load, 8 mA short circuit) output relay and turns the fault LED on) or disabled (in case of fault the corresponding output relay repeats the input line open or clo- • Output: voltage free SPDT relay contact sed status as configured). Contact material: AgCdO Contact rating: 2 A 250 Vac 500 VA, 2 A 250 Vdc 80 W D1030S single channel type has one input channel and two output (resistive load) 6 5 relays; the unit has two DIP switch configurable operating modes: Mechanical/Electrical life: 30 * 10 /1 * 10 , typical Mode A) input channel actuates in parallel the two output relays Operate/Release time: 7/3 ms, typical (DPDT contact). Bounce time NO/NC contact: 3/5 ms Relay actuation mode can be independently configured for each Response time: 20 ms output in two modes: Frequency response: maximum10 Hz NO input/NE relay or NO input/ND relay. Mode B) input channel actuates output relay A configurable in two • Environmental conditions: modes as in mode A above. Output relay B operates as a fault Operating: temperature limits -20 to + 60° C, output (in case of input fault, relay B actuates and the fault LED relative humidity max 90% non condensing, up to 35° C turns on while relay A repeats the input line as configured). Storage: temperature limits -45 to + 80° C Actuation can be DIP switch configured in two modes: No input fault/energized relay (it de-energizes in case of fault) or • Mounting: T35 DIN Rail according to EN50022 No input fault/de-energized relay (it energizes in case of fault). Connection: by polarized plug-in disconnect screw terminal blocks 2 to accomodate terminations up to2,5 mm Function: 1 or 2 channels I.S. switch repeater for contact or EN60947-5-6 • Degree of protection: IP 20 proximity. Provides 3 port isolation (input/output/supply). Signalling LEDs: • Compatibility: Power supply indication (green), output status (yellow), line fault CE mark compliant, conforms to 94/9/EC Atex Directive (red). and to 2004/108/CE EMC Directive Field Configurability: EMC: compatibility to EN61000-6-2, EN61000-6-4 NO/NC input for contact/proximitor, NE/ND relay operation and fault detection enable/disable. Use in hazardous area according to instruction manuals Current consumption (mA) Power dissipation (W) Max power consumption (W) N° Weight Voltage (@24 Vdc, input closed, (@24 Vdc, input closed, (@30 Vdc, in short circuit, ORDERING REFERENCES channels (g) relays energized) relays energized) relays energized) 24 V.d.c. 1 55 1,3 1,7 130 D1030S 24 V.d.c. 2 60 1,4 1,8 about 135 D1030D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-3 99Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-4 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, EN60079-26 II 3G Ex nA IIC T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079- [Ex iaD] associated electrical apparatus. 26, IEC61241-0, IEC61241-11, Uo/Voc = 10,7 V, Io/Isc = 15 mA, GM International CRR028 conforms to EN60079-0, EN60079-15, Po/Po = 39 mW at terminals 13-14, 15-16. UL & C-UL E222308 conforms to UL913 (Div.1), Um = 250 Vrms, -20 ° C ? Ta ? 60 ° C. UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 Location: No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, Class I, Zone 2, Group IIC, IIB, IIA T4 installation. 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, MAXIMUM EXTERNAL PARAMETERS Ukraine according to GOST 12.2.007.0, 22782.0, 22782.5 Exia IIC X, DNV and KR Type Approval Certificate for marine applications. Group Co/Ca Lo/La Lo/Ro Terminals CENELEC (uF) (mH) (uH/ohm) 13-14, 15-16 Uo/Voc = 10,7 V IIC 2,23 172 930 Io/Isc = 15 mA IIB 15,60 689 3720 Po/Po = 39 mW IIA 69,00 1379 7440 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, ZONE 2 GROUP IIC T4, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS I, ZONE 0, GROUP IIC GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1030D COMMON = 3 + POSITIVE Supply 24 Vdc CONNECTION = 4 - voltage free Proximity contact 8 NC = 13 + In 1 2 NO Out 1 - 14 1 COM voltage free Proximity contact 7 NC 15 + In 2 6 NO Out 2 - 16 = 5 COM MODEL D1030S = 3 + Supply 24 Vdc = 4 - voltage free Proximity contact = 8 NC 13 + In 1 Out 1-A 2 NO - 14 = 1 COM 7 NC 6 NO Out 2-B 5 COM Relay contact shown in de-energized position E-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-5 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Transistor Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 2 or 4 channels • 13 2 4 57 6 8 PWR ON 12 34 STATUS /FAULT 91 10112 13 14 15 16 114,5 22,5 Technical Data: General Description: The Switch/Proximity Detector Repeater type D1031 is a DIN Rail • Supply: 12 - 24 Vdc nom (from 10 to 30 Vdc) unit with two or four independent channels. The unit can be confi- reverse polarity protected, ripple within voltage limits ? 5 Vpp gured for contact or proximity detector, NO or NC and for NO or Current consumption @ 24V: 50 mA for 4 channels D1031Q, NC optocoupled open collector transistor output. 40 mA for 2 channels D1031D with input closed and transistors energized Each channel enables a Safe Area load to be controlled by a swit- Current consumption @ 12V: 100 mA for 4 channels D1031Q, ch, or a proximity detector, located in Hazardous Area. 80 mA for 2 channels D1031D with input closed and transistors energized D1031Q quad channel type has four independent input channels • Isolation (Test Voltage): In S.I./Out 1,5 KV; In S.I./Supply 1,5 KV; and actuates the corresponding output transistor. Two actuation Out/Supply 500 V; Out 1-3/Out 2-4 500 V modes can be independently DIP switch configured on each input channel: NO input/NC transistor or NO input/NO transistor. • Input switching current levels: ON ? 2,1 mA, Contact or proximity sensor and its connection line short or open OFF ? 1,2 mA, circuit fault detection is also DIP switch configurable: fault detection switch current ? 1,65 mA ± 0,2 mA hysteresis can be enabled (in case of fault it de-energizes the corresponding output transistor and turns the fault LED on) or disabled (in case of • Fault current levels: open fault ? 0,2 mA, fault the corresponding output transistor repeats the input line open short fault ? 6,8 mA, or closet status as configured). (when enabled both faults de-energize channel transistor with quad chan- nel unit D1031Q or actuate fault transistor with dual channel unit D1031D) D1031D dual channel type has two input channels and four output transistors; • Input equivalent source: 8 V 1 K? typical the unit has two DIP switch configurable operating modes: (8 V no load, 8 mA short circuit) Mode A) input channel actuates in parallel the two output transi- stors. • Output: voltage free SPST optocoupled open-collector transistor Transistor actuation mode can be independently configured for Open-collector rating: 100 mA at 35 V (voltage drop ? 2,0 V) each output in two modes: NO input/NC transitor or NO Leakage current: ? 50 A at 35 V) input/NO transistor. Response time: 500 s Mode B) input channel actuates output transistor A configurable in Frequency response: maximum1 KHz two modes as in mode A above. Output transistor B operates as a fault output (in case of input fault, transistor B actuates and the fault • Environmental conditions: LED turns on while transistor A repeats the input line as configu- Operating: temperature limits -20 to + 60° C, red). Actuation can be DIP switch configured in two modes: relative humidity max 90% non condensing, up to 35° C No input fault/energized transistor (it de-energizes in case of fault) Storage: temperature limits -45 to + 80° C or No input fault/de-energized transistor (it energizes in case of fault). • Mounting: T35 DIN Rail according to EN50022 Connection: by polarized plug-in disconnect screw terminal blocks 2 Function: to accomodate terminations up to 2,5 mm 2 or 4 channels I.S. switch repeater for contact or EN60947-5-6 proximity. • Degree of protection: IP 20 Provides 3 port isolation (input/output/supply). Signalling LEDs: • Compatibility: Power supply indication (green), output status (yellow), line fault CE mark compliant, conforms to 94/9/EC Atex Directive (red). and to 2004/108/CE EMC Directive Field Configurability: EMC: compatibility to EN61000-6-2, EN61000-6-4 NO/NC input for contact/proximitor, NO/NC transistor opera- tion and fault detection enable/disable. Use in hazardous area according to instruction manuals Power dissipation (W) Max power consumption (W) N° Weight Voltage (@24 Vdc, input closed, (@30 Vdc, in short circuit, ORDERING REFERENCES channels (g) transistors energized) transistors energized) 12 - 24 V.d.c. 2 1 1 120 D1031D 12 - 24 V.d.c. 4 1,2 1,4 about 130 D1031Q BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-5 99Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-6 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, EN60079-26 II 3G Ex nA II T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, [Ex iaD] associated electrical apparatus. IEC60079-26, IEC61241-0, IEC61241-11, Uo/Voc = 10,7 V, Io/Isc = 15 mA, IMQ 09 ATEX 013 X conforms to EN60079-0,EN60079-15, Po/Po = 39 mW at terminals 13-14, 15-16, 9-10, 11-12. UL & C-UL E222308 conforms to UL913 (Div.1), Um = 250 Vrms, -20 ° C ? Ta ? 60 ° C. UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 Location: No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, CSA-E60079-11 (Intrinsic Safety “i” Zone 0 & 1), Class I, Division 2, Groups A, B, C, D Temperature Code T4 and UL60079-15 (“n” Zone 2), Class I, Zone 2, Group IIC, IIB, IIA T4 installation. UL 1604 (Div. 2) for UL and CSA-C22.2 No. 157-92 (Div. 1), CSA-E60079-11 (Intrinsic Safety “i” Zone 0 & 1), CSA-E60079-15 (“n” Zone 2) for C-UL, MAXIMUM EXTERNAL PARAMETERS FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, Group Co/Ca Lo/La Lo/Ro Terminals E60079-11, E60079-15, CENELEC (uF) (mH) (uH/ohm) 13-14, 15-16 Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, Uo/Voc = 10,7 V IIC 2,23 172 930 Ukraine according to GOST 12.2.007.0, 22782.0, 22782.5 Exia IIC X, Io/Isc = 15 mA IIB 15,60 689 3720 DNV and KR Type Approval Certificate for marine applications. Po/Po = 39 mW IIA 69,00 1379 7440 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections SAFE AREA, HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, ZONE 2 GROUP IIC T4, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 CLASS I, ZONE 0, GROUP IIC MODEL D1031D COMMON = 3 + POSITIVE Supply 12-24 Vdc voltage free Proximity CONNECTION = 4 - contact + 13 = 1 Out 1-A In 1 - 2 Common Channel 1 14 + 15 5 Out 2-A In 2 - 6 Common Channel 2 16 7 Out 1-B 2 Common Channel 1 Out 2-B 8 = 6 Common Channel 2 MODEL D1031Q COMMON = 3 + POSITIVE Supply 12-24 Vdc voltage free Proximity CONNECTION = 4 - contact 13 + = 1 Out 1 In 1 - 2 Common Channels 1-3 14 15 + Out 2 5 In 2 - 6 Common Channels 2-4 16 + 9 7 Out 3 In 3 - 10 2 Common Channels 1-3 + 11 8 Out 4 In 4 = - 6 Common Channels 2-4 12 E-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-7 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Relay Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels • 13 2 4 57 6 8 PWR ON 12 STATUS /FAULT 13 14 15 16 114,5 22,5 General Description: Technical Data: The Switch/Proximity Detector Repeater type D1130 is a DIN Rail unit with one or two independent channels. The unit can be confi- • Supply: 115 - 230 Vac, 50-60 Hz nom (85 to 264 Vac, gured for contact or proximity detector, NO or NC and for NE or 48 to 400 Hz) or 100 to 350 Vdc, ND SPDT relay output contact. ripple within voltage limits ? 10 Vpp. Each channel enables a Safe Area load to be controlled by a swit- Limit supply voltage to 250 Vrms for Instrinsic Safety applications ch, or a proximity detector, located in Hazardous Area. • Isolation (Test Voltage): In S.I./Out 2,5 KV; In S.I./Supply 2,5 KV; D1130D dual channel type has two independent input channels Out/Supply 2,5 KV; Out/Out 2,5 KV and actuates the corresponding output relay. Two actuation modes can be independently DIP switch configured on each input chan- • Input switching current levels: ON ? 2,1 mA, nel: NO input/NE relay or NO input/ND relay. OFF ? 1,2 mA, Contact or proximity sensor and its connection line short or open switch current ? 1,65 mA ± 0,2 mA hysteresis circuit fault detection is also DIP switch configurable: fault detection can be enabled (in case of fault it de-energizes the corresponding • Fault current levels: open fault ? 0,2 mA, output relay and turns the fault LED on) or disabled (in case of fault short fault ? 6,8 mA, the corresponding output relay repeats the input line open or clo- (when enabled both faults de-energize channel relay with dual channel unit sed status as configured). D1130D or actuate fault relay with single channel unit D1130S) D1130S single channel type has one input channel and two output • Input equivalent source: 8 V 1 K? typical relays; the unit has two DIP switch configurable operating modes: (8 V no load, 8 mA short circuit) Mode A) input channel actuates in parallel the two output relays (DPDT contact). • Output: voltage free SPDT relay contact Relay actuation mode can be independently configured for each Contact material: AgCdO output in two modes: Contact rating: 2A 250 Vac 500 VA, 2A 250 Vdc 80 W NO input/NE relay or NO input/ND relay. (resistive load) 6 5 Mode B) input channel actuates output relay A configurable in two Mechanical/Electrical life: 30 * 10 /1 * 10 , typical modes as in mode A above. Output relay B operates as a fault Operate/Release time: 7/3 ms, typical output (in case of input fault, relay B actuates and the fault LED Bounce time NO/NC contact: 3/5 ms turns on while relay A repeats the input line as configured). Response time: 20 ms Actuation can be DIP switch configured in two modes: Frequency response: maximum10 Hz No input fault/energized relay (it de-energizes in case of fault) or No input fault/de-energized relay (it energizes in case of fault). • Environmental conditions: Operating: temperature limits -20 to + 60° C, Function: relative humidity max 90% non condensing, up to 35° C 1 or 2 channels I.S. switch repeater for contact or EN60947-5-6 Storage: temperature limits -45 to + 80° C proximity. Provides 3 port isolation (input/output/supply). • Mounting: T35 DIN Rail according to EN50022 Signalling LEDs: Connection: by polarized plug-in disconnect screw terminal blocks 2 Power supply indication (green), output status (yellow), line fault to accomodate terminations up to2,5 mm (red). Field Configurability: • Degree of protection: IP 20 NO/NC input for contact/proximitor, NE/ND relay operation and fault detection enable/disable. • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive Use in hazardous area according to instruction and to 2004/108/CE EMC Directive manuals EMC: compatibility to EN61000-6-2, EN61000-6-4 Current consumption (mA) Current consumption (mA) Max power consumption (W) N° Weight Voltage (@115 Vac, in short circuit, (@230 Vac, in short circuit, (@264 Vac, in short circuit, ORDERING REFERENCES channels (g) relays energized) relays energized) relays energized) 85 - 230 V.a.c. 1 25 15 1,9 140 D1130S 85 - 230 V.a.c. 2 25 15 2 about 145 D1130D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-7 99Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-8 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079- II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, 26 II 3G Ex nA IIC T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, [Ex iaD] associated electrical apparatus. IEC60079-26, IEC61241-0, IEC61241-11, Uo/Voc = 10,7 V, Io/Isc = 15 mA, GM International CRR028 conforms to EN60079-0, EN60079-15, Po/Po = 39 mW at terminals 13-14, 15-16. UL & C-UL E222308 conforms to UL913 (Div.1), Um = 250 Vrms, -20 ° C ? Ta ? 60 ° C. UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 Location: No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, Class I, Zone 2, Group IIC, IIB, IIA T4 installation. 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, MAXIMUM EXTERNAL PARAMETERS R 51330.10-99 [Exia] IIC X, Ukraine according to GOST 12.2.007.0,22782.0,22782.5 Exia IIC X, Group Co/Ca Lo/La Lo/Ro Terminals DNV and KR Type Approval Certificate for marine applications. CENELEC (uF) (mH) (uH/ohm) 13-14, 15-16 Uo/Voc = 10,7 V IIC 2,23 172 930 Io/Isc = 15 mA IIB 15,60 689 3720 Po/Po = 39 mW IIA 69,00 1379 7440 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, ZONE 2 GROUP IIC T4, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS I, ZONE 0, GROUP IIC GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1130D COMMON = 3 L POSITIVE Supply 115-230 Vac CONNECTION 4 N voltage free Proximity contact 8 NC = 13 + In 1 2 NO Out 1 - 14 1 COM voltage free Proximity contact 7 NC 15 + In 2 6 NO Out 2 - 16 = 5 COM MODEL D1130S = 3 L Supply 115-230 Vac 4 N voltage free Proximity contact = 8 NC 13 + In 1 Out 1-A 2 NO - 14 = 1 COM 7 NC 6 NO Out 2-B 5 COM Relay contact shown in de-energized position E-8 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-9 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Proximity Detector Repeater for analogue input Analogue Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels, input 4 - 20 mA • 13 2 4 57 6 8 PWR ON 91 10112 13 14 15 16 114,5 22,5 General Description: The single and dual channel DIN Rail Repeater Power Supply, D1010S and D1010D, provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA transmitters, or separa- tely powered 3, 4 wires 4-20, 0-20 mA transmitters located in Hazardous Area, and repeats the current in floating circuit to drive Technical Data: a Safe Area load. The circuit allows bi-directional communication signals, for Hart- • Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, Smart transmitters. ripple within voltage limits ? 5 Vpp Function: • Isolation (Test Voltage): In S.I./Out 1,5 KV; In S.I./Supply 1,5 KV 1 or 2 channels I.S. analog input for 2 wires loop powered or In S.I./In S.I. 500 V; Out/Supply 500 V; Out/Out 500 V separately powered Smart transmitters, provides 3 port isolation (input/output/supply) and current (source or sink) or voltage output • Input: 0/4 to 20 mA signal. (separately powered input, voltage drop ? 0,9 V) or 4 to 20 mA Signalling LED: (2 wire Tx current limited at ? 25 mA) Power supply indication (green). • Transmitter line voltage: ? 15 V at 20 mA Field Configurability: with max. 20 mVrms ripple on 0,5 at 40 KHz frequency band mA (source or sink) or V output signal. • Output: 0/4 at 20 mA, on max 600 ? load in source mode; Smart Communication Frequency Band: V min. 5 V with 0 ? load V max. 30 V in sink mode, 0,5 to 40 KHz within 3 dB (Hart and higher frequency protocols). current limited at ? 23 mA or 0/1 to 5 V on internal 250 ? shunt (or 0/2 to 10 V on internal 500 ? shunt on request) • Environmental conditions: Operating: temperature limits -20 to + 60° C, relative humidity max 90% non condensing, up to 35° C Storage: temperature limits -45 to + 80° C • Mounting: T35 DIN Rail according to EN50022 Connection: by polarized plug-in disconnect screw terminal blocks 2 to accomodate terminations up to2,5 mm Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. • Degree of protection: IP 20 • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive EMC: compatibility to EN61000-6-2, EN61000-6-4 Use in hazardous area according to instruction manuals Current consumption (mA) Power dissipation (W) N° Max power consumption (W) Weight Voltage (@24 Vdc, output 20 mA, (@24 Vdc, output 20 mA, ORDERING REFERENCES channels (@30 Vdc, in short circuit) (g) typical) typical) 24 V.d.c. 1 60 1 2 125 D1010S 24 V.d.c. 2 115 1,9 3,7 about 175 D1010D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-9 99Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-10 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Proximity Detector Repeater for analogue input Approvals: Safety parameters: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079- II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, 26 II 3G Ex nA II T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, [Ex iaD] associated electrical apparatus. IEC60079-26, IEC61241-0, IEC61241-11, Uo/Voc = 26,3 V, Io/Isc = 91 mA, IMQ 09 ATEX 013X conforms to EN60079-0, EN60079-15, Po/Po = 579 mW at terminals 14-15, 10-11. UL & C-UL E222308 conforms to UL913 (Div.1), Uo/Voc = 1,1 V, Io/Isc = 38 mA, UL 60079-0 (General, All Zones), Po/Po = 11 mW at terminals 15-16, 11-12. UL60079-11 (Intrinsic Safety “i” Zone 0 & 1), UL60079-15 (“n” Zone 2) UL Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1,05 nF, 1604 (Div. 2) for UL and CSA-C22.2 No.157-92 (Div.1), Li = 0 nH at terminals 15-16,11-12 CSA-E60079-0 (General, All Zones), Um = 250 Vrms, -20 ° C ? Ta ? 60 ° C. CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, CSA-C22.2 No. 213-M1987 (div. 2) and CSA-E60079-15 (“n” Zone 2) for Location: C-UL, FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, 3611, 3810 and C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079- Class I, Division 2, Groups A, B, C, D Temperature Code T4 and 0, E60079-11, E60079-15, Class I, Zone 2, Group IIC, IIB, IIA T4 installation. Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, MAXIMUM EXTERNAL PARAMETERS Ukraine according to GOST 12.2.007.0,22782.0,22782.5 Exia IIC X, TUV Certificate no. C-IS-183645-01, SIL 2/SIL 3 according to ISEC 61508. Group Co/Ca Lo/La Lo/Ro Terminals Please refer to Functional Safety Manual for SIL applications. CENELEC (uF) (mH) (uH/ohm) 14-15, 10-11 DNV and KR Type Approval Certificate for marine applications. IIC 0,095 4,3 59,6 Uo/Voc = 26,3 V IIB 0,738 17,2 238,4 Io/Isc = 91 mA IIA 2,508 34,5 476,8 Po/Po = 597 mW Group Co/Ca Lo/La Lo/Ro Terminals CENELEC (uF) (mH) (uH/ohm) 15-16, 11-12 NOTE for USA and Canada: Uo/Voc = 1,1 V IIC 100 11,3 3490 IIC equal to Gas Groups A, B, C, D, E, F and G Io/Isc = 38 mA IIB 1000 45,3 13963 IIB equal to Gas Groups C, D, E, F and G Po/Po = 11 mW IIA 1000 90,7 27927 IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, ZONE 2 GROUP IIC T4, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS I, ZONE 0, GROUP IIC GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1010D = 3 + Supply 24 Vdc = Out 1 4 - = 2 Wire Tx Source I Source V External HHT HHT + + + Powered Tx Sink I 14 1 = mA RL + + In 1 V + 15 2 - - - mA = 8 16 - - = = Out 2 = Source I Source V 2 Wire Tx External HHT HHT + + + Powered Tx Sink I 10 5 = mA RL + + In 2 + 11 6 V - - - mA = 7 12 - - MODEL D1010S = 3 + Supply 24 Vdc Out 1 = 4 - = 2 Wire Tx Source I Source V External HHT HHT + + + Powered Tx Sink I 14 1 = mA RL + + In 1 + 15 2 V - - - mA = 8 16 - - Relay contact shown in de-energized position E-10 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.comCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-11 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, ZONE 2 GROUP IIC T4, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS I, ZONE 0, GROUP IIC GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 Safety Description Connections for Duplication of Active Input Signals Terminals 15 -12 Restriction on specifications for external powered Transmitter: Uo/Voc = 2,2 V The voltage drop must be changed in 1,8 V maximum Io/Isc = 38 mA The safety parameters must be changed in: Uo/Voc = 2,2 V, Io/Isc = 38 mA, Po/Po = 21 mW Po/Po = 21 mW Group Co/Ca Lo/La Lo/Ro CENELEC (µF) (mH) (µH/?) IIC 100 11,3 849 IIB 1000 45,3 3396 MODEL D1010D Duplicator IIA 1000 90,7 6793 = 3 + Supply 24 Vdc = Out 1-A 4 - = Source I Source V External HHT + + Powered Tx Sink I 14 1 = mA RL + + In 1 + 2 V 15 - - mA = 16 8 - - = = Out 1-B = Source I Source V HHT + + Sink I 10 5 = mA RL + + V 11 6 - - mA = 7 12 - Relay contact shown in de-energized position Safety Description Connections for Duplication of 2 wires Transmitter Input Terminals 14 -11 Restriction on specifications for 2 wires Transmitter Input: Uo/Voc = 27,4 V Bidirectional communication for Smart Transmitter is provided only on channel 1 Io/Isc = 91 mA The minimum supply voltage available for Transmitter (Vtx) is 14,1 V at 20 mA input Po/Po = 624 mW The safety parameters must be changed in: Uo/Voc = 27,4 V, Io/Isc = 91 mA, Po/Po = 624 mW Group Co/Ca Lo/La Lo/Ro CENELEC (µF) (mH) (µH/?) IIC 0,085 4,3 54,7 IIB 0,675 17,2 218,9 MODEL D1010D Duplicator IIA 2,258 34,5 437,9 = 3 + Supply 24 Vdc = Out 1-A 4 - = 2 Wire Tx Source I Source V HHT HHT + In 1 + + Sink I 14 1 = mA RL + + 2 V 15 - - - mA = 8 16 - = = Out 1-B = Source I Source V HHT + + Sink I 10 5 = mA RL + V + 11 6 - - mA = 7 12 - Relay contact shown in de-energized position BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com E-11Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina F-1 MALE CONNECTORS PREASSEMBLED ON SENSORS General informations: This section presents sensors already cabled to male connectors for particular applications. Specific cable lengths are available upon request on all the products. BDC versions with rotating nut allow the direct connection to the connection boxes reducing the costs and improving the reliability of the plant. Other solutions with different products are possible according to customer specification. The suggested connectors have to be matched to the sensors according to the cable sections, indicated on the ordering references tables inside the catalogue. HOW TO COMPOSE THE ORDERING REFERENCES Type DCA 12 / 4 H 0 9 KS3GD - 0,3 Cable lenght (m) Suitable for Degree of Type Dimensions Manufacturer Series cables diameter protection (mm) 50 18 13 2 H 3 1 BDC M12 x 1 rotating nut IP68 5 4 M12 x 1 SW14 Note: more detailed technical data are available on specific manufacturers data sheets. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com F-1 Ø14,5 Ø 10,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-1 HOW TO INTERPRETE THE ORDERING REFERENCES CONNECTORS MOULDED WITH CABLE N° Connector: 8B = right angled female M12 x 1 for d.c. sensors 9 = straight male M12 x 1 for d.c. sensors 9B = right angled male M12 x 1 for d.c. sensors 10 = straight female M12 x 1 for d.c. sensors CP 10/0032VA N° conductors: 2 = 2 wires 3 = 3 wires 4 = 4 wires 5 = 5 wires Cable length m. 2 = 2 m. 5 = 5 m. 10 = 10 m. Cable material: PV = PVC (blue for 1GD; grey for 3GD) PR = PUR (blue for 1GD; black for 3GD) T = Thermoplastic grey rubber (-40° ÷ + 140° C) Atex Versions: A = Category 1G-1D 3GD = Category 3G-3D Note: When using female connectors, please consider an insertion length inside the sensor, which is: M12 connectors = 8 mm I.E. Sensor DCA8/4309KS3GD total length = 60 mm Connector C8B/0032PV3GD total length = 29 mm Overall dimension sensor + connector = (60 + 29) - 8 = 81 mm. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com G-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-3 FEMALE CONNECTORS M12 x 1 For ATEX sensors • Degree of protection IP68 - Straight in d.c. • Moulded with cable • According to 94/9/CE - EN60079-0 - EN 60947-5-2 • Connector 10A 44 12 13 2 1 3 4 M12 x 1 SW14 General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The 2-wire model is suitable for NAMUR sensors either on N.O. or N.C. ver- sion. It is possible to use it in zone 0 or 20 without additional protection again- st electrostatic charges. Particular moulding processes assure the maximum sealing, making these pro- ducts suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual sup- plied together the sensors. Technical data: • Operating voltage: max 50 Vac/75 Vdc • Maximum current: 4 A • Contact resistance: ? 5 m? • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range for PUR and PVC versions: - 25° ÷ + 90°C for HT versions: - 40° ÷ + 120°C • Degree of protection: IP68 with plug in fully locked position = HT, thermoplastic rubber - 40° ÷ + 140°C * ORDERING REFERENCES Category 1G -1D 3G - 3D 3G - 3D Zone 0 -20 2 - 22 2 - 22 Cap. cable 140 170 170 pF/m Indutt. cable 0,4 0,8 0,8 µH/m Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) 2 2 2 Section 2 x 0,75 mm - ø ext. 5 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown brown + brown 1 1 + + 1 black output NO blue _ black 4 output 2 4 white output NC blue 2 - 3 blue _ 4 3 10A PVC 2 C10/0022PVA C10/0032PV3GD C10/0042PV3GD 10A PVC 5 C10/0025PVA C10/0035PV3GD C10/0045PV3GD 10A PVC 10 C10/00210PVA C10/00310PV3GD C10/00410PV3GD 10A PUR 2 C10/0022PRA C10/0032PR3GD C10/0042PR3GD 10A PUR 5 C10/0025PRA C10/0035PR3GD C10/0045PR3GD 10A PUR 10 C10/00210PRA C10/00310PR3GD C10/00410PR3GD 10A HT* 2 - C10/0032T3GD C10/0042T3GD 10A HT* 5 - C10/0035T3GD C10/0045T3GD 10A HT* 10 - C10/00310T3GD C10/00410T3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com G-3 Connector n° Material Ø14,5 Lenght m. Ø 10,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-4 FEMALE CONNECTORS M12 x 1 • For ATEX sensors • Right angled in d.c. - Degree of protection IP68 • Moulded with cable • According to 94/9/CE - EN60079-0 - EN60947-5-2 Connector 8A 29 SW14 12 2 1 3 4 38,5 M12 x 1 7, 3 17 Ø 10,5 General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The 2-wire model is suitable for NAMUR sensors either on N.O. or N.C. ver- sion. It is possible to use it in zone 1 or 21 without additional protection again- st electrostatic charges. Particular moulding processes assure the maximum sealing, making these pro- ducts suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual sup- plied together the sensors. Technical data: • Operating voltage: max 50 Vac/75 Vdc • Maximum current: 4 A • Contact resistance: ? 5 m? • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range for PUR and PVC versions: - 25° ÷ + 90°C For HT versions: - 40° ÷ + 120°C • Degree of protection: IP68 with plug in fully locked position = HT, thermoplastic - 40° ÷ + 140°C * ORDERING REFERENCES Category 2G -2D 3G - 3D 3G - 3D Zone 1 - 21 2 - 22 2 - 22 Cap. cable 140 170 170 pF/m Indutt. cable 0,4 0,8 0,8 µH/m Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) 2 2 2 Section 2 x 0,75 mm - ø ext. 5 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown brown brown 1 + + 1 1 + black output NO black 4 blue _ output white 2 4 2 output NC blue 3 - blue _ 4 3 8A PVC 2 C8B/0022PVA C8B/0032PV3GD C8B/0042PV3GD 8A PVC 5 C8B/0025PVA C8B/0035PV3GD C8B/0045PV3GD 8A PVC 10 C8B/00210PVA C8B/00310PV3GD C8B/00410PV3GD 8A PUR 2 C8B/0022PRA C8B/0032PR3GD C8B/0042PR3GD 8A PUR 5 C8B/0025PRA C8B/0035PR3GD C8B/0045PR3GD 8A PUR 10 C8B/00210PRA C8B/00310PR3GD C8B/00410PR3GD 8A HT* 2 - C8B/0032T3GD C8B/0042T3GD 8A HT* 5 - C8B/0035T3GD C8B/0045T3GD 8A HT* 10 - C8B/00310T3GD C8B/00410T3GD G-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Connector n° Material Lenght m. Ø14,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-5 MALE CONNECTORS M12 x 1 For ATEX applications • Straight in d.c. • Moulded with cable • According to 94/9/CE - EN60079-0 - EN 60947-5-2 • Connector 9A 50 18 13 2 3 1 4 M12 x 1 SW14 General features: Particular moulding processes assure the maximum sealing, making these pro- ducts suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual sup- plied together the sensors. Technical data: • Operating voltage: max 50 Vac/75 Vdc • Maximum current: 4 A • Contact resistance: ? 5 m? • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range: - 25° ÷ + 90°C • Degree of protection: IP68 with plug in fully locked position ORDERING REFERENCES Category 3G - 3D 3G - 3D Zone 2 - 22 2 - 22 Cap. cable 170 170 pF/m Indutt. cable 0,8 0,8 µH/m Cable 3-wires (grey) 4-wires (grey) 2 2 Section 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown + brown 1 + 1 black output NO black 4 output 4 white output NC blue 2 - 3 blue _ 3 9A PVC 2 C9/0032PV3GD C9/0042PV3GD 9A PVC 5 C9/0035PV3GD C9/0045PV3GD 9A PVC 10 C9/00310PV3GD C9/00410PV3GD 9A PUR 2 C9/0032PR3GD C9/0042PR3GD 9A PUR 5 C9/0035PR3GD C9/0045PR3GD 9A PUR 10 C9/00310PR3GD C9/00410PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com G-5 Connector n° Ø14,5 Material Lenght m. Ø 10,5Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-6 MALE CONNECTORS M12 x 1 • For ATEX applications • Right angled in d.c. - Degree of protection IP68 • Moulded with cable • According to 94/9/CE - EN60079-0 - EN60947-5-2 Connector 9C 35 SW14 18 2 3 1 4 38,5 M12 x 1 SW14 17 Ø 10,5 General features: Note: use in hazardous area must be according to the instruction manual sup- plied together the sensors. Technical data: • Operating voltage: max 50 Vac/75 Vdc • Maximum current: 4 A • Contact resistance: ? 5 m? • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range: - 25° ÷ + 90°C • Degree of protection: IP68 with plug in fully locked position ORDERING REFERENCES Category 3G - 3D 3G - 3D Zone 2 - 22 2 - 22 Cap. cable 170 170 pF/m Indutt. cable 0,8 0,8 µH/m Cable 3-wires (grey) 4-wires (grey) 2 2 Section 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown brown 1 + 1 + black output NO black 4 output 4 white blue 2 output NC 3 - blue _ 3 9C PVC 2 C9B/0032PV3GD C9B/0042PV3GD 9C PVC 5 C9B/0035PV3GD C9B/0045PV3GD 9C PVC 10 C9B/00310PV3GD C9B/00410PV3GD 9C PUR 2 C9B/0032PR3GD C9B/0042PR3GD 9C PUR 5 C9B/0035PR3GD C9B/0045PR3GD 9C PUR 10 C9B/00310PR3GD C9B/00410PR3GD G-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Connector n° Material Ø14,5 Lenght m.Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-1 HOW TO INTERPRETE THE ORDERING REFERENCES MOULDED CONNECTING CABLES FOR ATEX SENSORS N° Male connector: 9 = straight M12 x 1 9B = right angled M12 x 1 N° Female connector: 8B = right angled M12 x 1 10 = straight M12 x 1 C9 / C10 / 00 2 - 0,6 PV A 00 = without LED N° conductors: 2 = 2 wires 3 = 3 wires 4 = 4 wires Cable length 0,6 = 0,6 m 1 = 1 m 2 = 2 m Other cable lengths upon request Cable material: PV = PVC PR = PUR Category: A = 1G-1D or 2G-2D 3GD = 3G-3D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com H-1Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-3 MOULDED CONNECTING CABLES FOR ATEX SENSORS MALE M12 x 1 straight • FEMALE M12 x 1 • According to 94/9CE - EN60079-0 - EN60947-5-2 • C9/C10/… 44 50 18 13 13 12 Ø 10,5 Ø 10,5 Ø14,5 Ø14,5 M12 x 1 SW14 SW14 M12 x 1 22 1 1 2 wires version 4 4 3 1 1 3 3 wires version 4 4 2 2 4 wires version 3 1 1 3 4 4 C9/C8B/… Ø 14,5 M12 x 1 50 7, 3 12 18 13 Ø 10,5 Ø 10,5 29 Ø 14,5 17 M12 x 1 SW14 38,5 22 1 1 2 wires version Technical data: 4 4 • Operating voltage max 50 Vac/75 Vdc • Maximum current: 4 A 3 1 1 3 3 wires version • Contact resistance: ? 5 m? 4 4 • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) 2 2 • Moulding: PUR 3 1 4 wires version 1 3 • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range: - 25 ÷ + 90°C 4 4 • Degree of protection: IP68 with plug in fully locked position Note: use in hazardous area must be according to the instruction manual supplied together the sensors. ORDERING REFERENCES Category 1G - 1D 2G - 2D 3G - 3D 3G - 3D Zone 0 - 20 1 - 21 2 - 22 2 - 22 Cap.cable 140 170 170 pf/m Indutt. cable 0,4 0,8 0,8 uH/m Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) 2 2 2 Section 2 x 0,75 mm - ø ext. 5 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown brown + brown 1 + 1 1 + black output NO blue black 4 _ output 4 white 2 blue 2 output NC 3 - blue 4 _ 3 • Male straight • Male straight • Male straight • Male straight • Male straight • Male straight • Female straight • Female right angled • Female straight • Female right angled • Female straight • Female right angled PVC 0,6 C9/C10/002-0,6PVA C9/C8B/002-0,6PVA C9/C10/003-0,6PV3GD C9/C8B/003-0,6PV3GD C9/C10/004-0,6PV3GD C9/C8B/004-0,6PV3GD PVC 1 C9/C10/002-1PVA C9/C8B/002-1PVA C9/C10/003-1PV3GD C9/C8B/003-1PV3GD C9/C10/004-1PV3GD C9/C8B/004-1PV3GD PVC 2 C9/C10/002-2PVA C9/C8B/002-2PVA C9/C10/003-2PV3GD C9/C8B/003-2PV3GD C9/C10/004-2PV3GD C9/C8B/004-2PV3GD PUR 0,6 C9/C10/002-0,6PRA C9/C8B/002-0,6PRA C9/C10/003-0,6PR3GD C9/C8B/003-0,6PR3GD C9/C10/004-0,6PR3GD C9/C8B/004-0,6PR3GD PUR 1 C9/C10/002-1PRA C9/C8B/002-1PRA C9/C10/003-1PR3GD C9/C8B/003-1PR3GD C9/C10/004-1PR3GD C9/C8B/004-1PR3GD PUR 2 C9/C10/002-2PRA C9/C8B/002-2PRA C9/C10/003-2PR3GD C9/C8B/003-2PR3GD C9/C10/004-2PR3GD C9/C8B/004-2PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com H-3 H-3 Material Lenght m.Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-4 MOULDED CONNECTING CABLES FOR ATEX SENSORS • MALE M12 x 1 right angled • FEMALE M12 x 1 • According to 94/9/CE - EN60079-0 - EN 60947-5-2 C9B/C10/… Ø14,5 M12 x 1 SW14 44 18 17 13 12 Ø 10,5 Ø 10,5 35 Ø 14,5 38,5 SW14 M12 x 1 22 1 1 2 wires version 4 4 3 1 1 3 3 wires version 4 4 2 2 3 1 4 wires version 1 3 4 4 C9B/C8B/… Ø14,5 M12 x 1 Ø 14,5 M12 x 1 SW14 18 7, 3 12 17 Ø 10,5 Ø 10,5 35 29 17 38,5 38,5 22 Technical data: 1 2 wires version 1 • Operating voltage max 50 Vac/75 Vdc 4 4 • Maximum current: 4 A • Contact resistance: ? 5 m? 3 1 1 3 3 wires version • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 µm) • Moulding: PUR 4 4 • Locking nut: self-locking in CuZn, nickel plated brass 2 2 • Temperature range: - 25 ÷ + 90°C 4 wires version 3 1 1 3 • Degree of protection: IP68 with plug in fully locked position 4 4 Note: use in hazardous area must be according to the instruction manual supplied together the sensors. ORDERING REFERENCES Category 2G - 2D 3G - 3D 3G - 3D Zone 1 - 21 2 - 22 2 - 22 Cap.cable 140 170 170 pf/m Indutt. cable 0,4 0,8 0,8 uH/m Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) 2 2 2 Section 2 x 0,75 mm - ø ext. 5 3 x 0,50 mm - ø ext. 5 4 x 0,35 mm - ø ext. 5 brown brown + brown 1 + 1 1 + black output NO blue black 4 _ output 4 white 2 blue 2 output NC 3 - blue 4 _ 3 • Male straight • Male straight • Male straight • Male straight • Male straight • Male straight • Female straight • Female right angled • Female straight • Female right angled • Female straight • Female right angled PVC 0,6 C9B/C10/002-0,6PVA C9B/C8B/002-0,6PVA C9B/C10/003-0,6PV3GD C9B/C8B/003-0,6PV3GD C9B/C10/004-0,6PV3GD C9B/C8B/004-0,6PV3GD PVC 1 C9B/C10/002-1PVA C9B/C8B/002-1PVA C9B/C10/003-1PV3GD C9B/C8B/003-1PV3GD C9B/C10/004-1PV3GD C9B/C8B/004-1PV3GD PVC 2 C9B/C10/002-2PVA C9B/C8B/002-2PVA C9B/C10/003-2PV3GD C9B/C8B/003-2PV3GD C9B/C10/004-2PV3GD C9B/C8B/004-2PV3GD PUR 0,6 C9B/C10/002-0,6PRA C9B/C8B/002-0,6PRA C9B/C10/003-0,6PR3GD C9B/C8B/003-0,6PR3GD C9B/C10/004-0,6PR3GD C9B/C8B/004-0,6PR3GD PUR 1 C9B/C10/002-1PRA C9B/C8B/002-1PRA C9B/C10/003-1PR3GD C9B/C8B/003-1PR3GD C9B/C10/004-1PR3GD C9B/C8B/004-1PR3GD PUR 2 C9B/C10/002-2PRA C9B/C8B/002-2PRA C9B/C10/003-2PR3GD C9B/C8B/003-2PR3GD C9B/C10/004-2PR3GD C9B/C8B/004-2PR3GD H-4 H-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:bdc@bdcelectronic.com Material Lenght m.Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-5 NOTESCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-6 NOTESCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-7 NOTESCatalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-8 The physical appearance of the actual devices may be different from the illustrations shown. BDC Electronic srl advises that the descriptions and subjects of the catalogue may be changed without notice. Copy and imitation of this catalogue are strictly forbidden by copyright laws. Printed in November 2012 Design by Prandi Image - Torino - Italy Pictures by Prandi Image - Torino - Italy
    E-endustri.com'u takip edin
    e-endustri.com Hesaplı Alışveriş Kredi kartları